Foetal electrocardiograph (ST-analyser or STAN) for intrapartum foetal heart rate monitoring: a friend or a foe?

Pages 123-127 | Received 30 Oct 2016, Accepted 07 Dec 2016, Published online: 23 Jan 2017
 

Abstract

Cardiotocograph (CTG) is associated with a high false positive rate of up to 60% which may increase the risk of unnecessary intrapartum interventions (emergency caesarean sections or operative vaginal deliveries) without any significant benefits. A recent study on variation of caesarean section rates in England has concluded that there was a very wide variation even in the adjusted rates of caesarean section from 14.9% to 32.1%. Cochrane Systematic Reviews have concluded that the use of FBS does not reduce caesarean section rate or any pre-specified neonatal outcomes. Fetal ECG (ST-Analyser or STAN) has been used in the clinical practice for more than 20 years. Although, initial randomised controlled trials (RCTs) showed great promise regarding the role of STAN in reducing operative delivery rates (instrumental vaginal births and emergency caesarean sections) and neonatal metabolic acidosis, subsequent studies have questioned the role of STAN in clinical practice. A recent meta-analysis which included six randomised controlled trials (a total of 26,446 women) has concluded that there was a 36% reduction in the rate of neonatal metabolic acidosis. Practising clinicians currently face a dilemma as to whether STAN has a place in contemporary obstetric practice or whether it?s use should be discouraged and discontinued.

Acknowledgements

E. C. conducts several Master classes on CTG and foetal ECG in the UK, Europe, Asia, and Australia and is the co-organizer of the Intrapartum Foetal Surveillance Course at the Royal College of Obstetricians and Gynaecologists (RCOG) and Foetal Monitoring Courses at St George’s University of London. He uses foetal ECG for intrapartum foetal heart rate monitoring and is a member of the Editorial Board for NHS e-learning on CTG and a Course lead for the Baby Lifeline CTG Masterclasses. Organisers of some of these Masterclasses have received sponsorships from Philips, Neoventa, Euroking, Huntleigh, K2 and other industry to support these Masterclasses. However, E.C. does not have any financial or managerial interests in any pharmaceutical or medical device industry. EC was one of the three-member guideline development group which revised the international FIGO Guidelines on CTG in 2015.

Disclosure statement

The author reports that he has no conflicts of interest to declare.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access
  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart
* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.