292
Views
0
CrossRef citations to date
0
Altmetric
Research Article

Validation of N95 respirator models for pressure drop and particle capture efficiency

, , &
Pages 390-400 | Published online: 13 Jul 2023
 

Abstract

Despite efforts to apply administrative and engineering controls to minimize worker exposure to aerosols, filtering facepiece respirators (FFRs) continue to be an important form of personal protective equipment in hard-to-control settings such as healthcare, agriculture, and construction. Optimizing the performance of FFRs can be advanced with the use of mathematical models that incorporate the forces that act on particles during filtration as well as those filter characteristics that influence filter pressure drop. However, a thorough investigation of these forces and characteristics using measurements of currently available FFRs has not been undertaken. Filter characteristics such as fiber diameter and filter depth were measured from samples taken from six currently-available N95 FFRs from three manufacturers. A filtration model was developed that included diffusion, inertial and electrostatic forces to estimate the filtration of an aerosol with a Boltzmann charge distribution. The diameter of the filter fibers was modeled as either a single “effective” diameter or as a lognormal distribution of diameters. Both modeling schemes produced an efficiency curve that simulated efficiency measurements made over a range of particle diameters (0.01 − 0.3 µm) with the use of a scanning mobility particle sizer in the region where efficiency is at a minimum. However, the method using a distribution of fiber diameters produced a better fit for particles > 0.1 µm. The coefficients associated with a simple form of the diffusion equation constituting a power law incorporating the Peclet number were adjusted to enhance model accuracy. Likewise, the fiber charge of the electret fibers was also adjusted to maximize model fit but remained within levels reported by others. A filter pressure drop model was also developed. Results demonstrated the need for a pressure drop model applicable to N95s relative to existing models developed with the use of fibers with larger diameters than those used in current N95 FFRs. A set of N95 FFR characteristics are provided that can be used to develop models of typical N95 FFR filter performance and pressure drop in future studies.

Data availability

All data created as part of this research is available upon request from the corresponding author. All filter efficiency models produced as a result of this study, in either Excel or MATLAB, are available upon request of the corresponding author.

Additional information

Funding

This research was supported by the University of Iowa Environmental Health Sciences Research Center (NIH P30 ES005605), and by the Heartland Center for Occupational Health and Safety, a NIOSH/CDC Education and Research Center (T42OH008491).

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 148.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.