Care solution effects on contact lens in vivo wettability

, PhD, , PhD, , PhD, , PhD & , DSc FCOptom FAAO
Pages 623-632 | Received 16 Apr 2016, Accepted 11 Nov 2016, Published online: 15 Apr 2021
 

Abstract

Background

The aim of the study was to evaluate the effect of care solutions on contact lens in vivo wettability using Doane's interferometric technique.

Methods

Thirteen subjects (aged 26.6 ± 6.3-years) participated for contact lens wettability evaluation after soaking in five care solutions namely Opti‐Free EverMoist (now called puremoist), Opti‐Free Express (Alcon), COMPLETE (AMO), ReNu and Biotrue (Bausch & Lomb). A new pair of lenses was soaked in the solutions for eight hours (prior to wear) or taken directly from pack solutions (as control) and worn by the subjects. The total number of pairs of lenses tested was 13 by six (78 lenses; 13 pairs of lenses wetted in five care solutions plus the pack solution). Doane's interferometer was used to capture images of the pre‐lens film on a single type of contact lens, Acuvue Oasys (Johnson & Johnson). The lens in vivo wettability was evaluated after 15 minutes and eight hours of wear by each subject. Four parameters: onset latency, drying duration, maximum speed and peak latency were used to assess the lens wettability.

Results

After eight hours, the solutions showing significant reduction in contact lens wettability were the following. For onset latency: Pack solution, Biotrue Opti‐Free EverMoist and Express; for drying duration: pack solution, ReNu and Opti‐Free EverMoist; for peak latency; pack solution, Biotrue and Opti‐Free EverMoist. Regarding the maximum speed, lenses soaked in Pack solution, ReNu and Opti‐Free EverMoist showed a significant increase (worsening). The comparative study showed that there were significant differences among the performance of the care solutions.

Conclusion

This novel thin film interferometric technique was able to measure, objectively, contact lens in vivo wettability, following the use of care solutions. COMPLETE was the only solution that showed no significant change in the lens wettability (with the all parameters) between the initial and the end of day.

ACKNOWLEDGEMENT

The authors extend their appreciation to the college of Applied Medical Sciences Research Centre and Deanship of Scientific Research at King Saud University for its funding for this research.

Additional information

Funding

Applied Medical Sciences Research Centre
Deanship of Scientific Research at King Saud University

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Purchase Issue

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 84.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.