Abstract
Aim: The GuideLiner (GL) is a widely used catheter primarily in complex percutaneous coronary intervention (PCI). Deep seating of the GL and distal stent placement may be facilitated by the anchor-balloon technique (ABT). Methods: We aimed to prospectively analyze procedural details, technical success, complications and in-hospital outcome in patients who underwent PCI using the GL catheter and the ABT. Results: A total of 118 patients underwent PCI with the aid of the GL and ABT. Procedure success rate was 95% (112/118) and only seven patients (5.9%) encountered complications. ABT was indicated and successfully used in 29 patients (25%). Conclusion: GL and ABT successfully aided stent delivery in unfavorable and heavily calcified lesions which otherwise may have been considered unsuitable for PCI.
Financial & competing interests disclosure
The authors have no relevant affiliations or financial involvement with any organization or entity with a financial interest in or financial conflict with the subject matter or materials discussed in the manuscript. This includes employment, consultancies, honoraria, stock ownership or options, expert testimony, grants or patents received or pending, or royalties.
No writing assistance was utilized in the production of this manuscript.
Ethical conduct of research
The authors state that they have obtained appropriate institutional review board approval or have followed the principles outlined in the Declaration of Helsinki for all human or animal experimental investigations. In addition, for investigations involving human subjects, informed consent has been obtained from the participants involved.