65
Views
0
CrossRef citations to date
0
Altmetric
Research Article

Anchor-balloon Technique to Facilitate Stent Delivery Via the Guideliner Catheter in Percutaneous Coronary Intervention

, , , , , , , , , , & show all
Pages 291-299 | Received 25 Sep 2017, Accepted 22 May 2018, Published online: 21 Jun 2018

References

  • Ikari Y , MasudaN, MatsukageTet al. Backup force of guiding catheters for the right coronary artery in transfemoral and transradial interventions . J. Invasive Cardiol.21 ( 11 ), 570 – 574 ( 2009 ).
  • Abdelaal E , Brousseau-ProvencherC, MontminySet al. Risk score, causes, and clinical impact of failure of transradial approach for percutaneous coronary interventions . JACC Cardiovasc. Interv.6 ( 11 ), 1129 – 1137 ( 2013 ).
  • Jafary FH . When one won’t do it, use two-double “buddy” wiring to facilitate stent advancement across a highly calcified artery . Catheter. Cardiovasc. Interv.67 ( 5 ), 721 – 723 ( 2006 ).
  • Fujita S , TamaiH, KyoEet al. New technique for superior guiding catheter support during advancement of a balloon in coronary angioplasty: the anchor technique . Catheter. Cardiovasc. Interv.59 ( 4 ), 482 – 488 ( 2003 ).
  • Sharma D , ShahA, OstenMet al. Efficacy and safety of the GuideLiner mother-in-child guide catheter extension in percutaneous coronary intervention . J. Interv. Cardiol.30 ( 1 ), 46 – 55 ( 2017 ).
  • Burzotta F , TraniC, MazzariMAet al. Use of a second buddy wire during percutaneous coronary interventions: a simple solution for some challenging situations . J. Invasive Cardiol.17 ( 3 ), 171 – 174 ( 2005 ).
  • Mamas MA , Fath-OrdoubadiF, FraserDG . Distal stent delivery with GuideLiner catheter: first in man experience . Catheter. Cardiovasc. Interv.76 ( 1 ), 102 – 111 ( 2010 ).
  • Kumar S , GorogDA, SeccoGG, Di MarioC, KukrejaN . The GuideLiner “child” catheter for percutaneous coronary intervention-early clinical experience . J. Invasive Cardiol.22 ( 10 ), 495 – 498 ( 2010 ).
  • Wiper A , MamasM, El-OmarM . Use of the GuideLiner catheter in facilitating coronary and graft intervention . Cardiovasc. Revasc. Med.12 ( 68 ), 5 – 7 ( 2011 ).
  • Michael TT , BrilakisES . Challenges associated with use of the GuideLiner catheter in percutaneous coronary interventions . J. Invasive Cardiol.24 ( 7 ), 370 – 371 ( 2012 ).
  • Murphy JC , SpenceMS . Guideliner catheter--friend or foe?Catheter. Cardiovasc. Interv.80 ( 3 ), 447 – 450 ( 2012 ).
  • Nesto RW , SassowerMA . PTCA of “shepherd’s crook” right coronary arteries with a new shape of guiding catheter . Cathet. Cardiovasc. Diagn.29 ( 1 ), 70 – 73 ( 1993 ).
  • Alkhalil M , SmythA, WalshSJet al. Did the use of the GuideLiner V2(TM) guide catheter extension increase complications? A review of the incidence of complications related to the use of the V2 catheter, the influence of right brachiocephalic arterial anatomy and the redesign of the V3(TM) GuideLiner and clinical outcomes . Open Heart3 ( 1 ), e000331 ( 2016 ).
  • Gossman DE , TuzcuEM, SimpfendorferC, BeckGJ . Percutaneous transluminal angioplasty for shepherd’s crook right coronary artery stenosis . Cathet. Cardiovasc. Diagn.15 ( 3 ), 189 – 191 ( 1988 ).
  • Ramsdale DR , BellamyCM, GrechED, AggarwalRK, MyskowMW . Early experience of directional coronary atherectomy: clinical results, complications and histopathological findings . Int. J. Cardiol.43 ( 2 ), 127 – 137 ( 1994 ).
  • Shriki JE , ShinbaneJS, RashidMA . Identifying, characterizing, and classifying congenital anomalies of the coronary arteries . Radiographics32 ( 3 ), 453 – 468 ( 2012 ).
  • De Man FH , TandjungK, HartmannM . Usefulness and safety of the GuideLiner catheter to enhance intubation and support of guide catheters: insights from the Twente GuideLiner registry . EuroIntervention8 ( 3 ), 336 – 344 ( 2012 ).
  • Eddin MJ , ArmstrongEJ, JavedU, RogersJH . Transradial interventions with the GuideLiner catheter: role of proximal vessel angulation . Cardiovasc. Revasc. Med.14 ( 5 ), 275 – 279 ( 2013 ).
  • Li SS , ChengCW . Coronary angioplasty on an impassable calcified stenosis using a buddy balloon technique . Catheter. Cardiovasc. Interv.62 ( 1 ), 35 – 37 ( 2004 ).
  • Di Mario C , RamasamiN . Techniques to enhance guide catheter support . Catheter. Cardiovasc. Interv.72 ( 4 ), 505 – 512 ( 2008 ).
  • Elbarouni B , MoussaM, KassM, TolevaO, VoM, RavandiA . GuideLiner balloon assisted tracking (GBAT): a new addition to the interventional toolbox . Case Rep. Cardiol.2016, 6715630 ( 2016 ).
  • Patel T , ShahS, PancholyS, RaoS, BertrandOF, KwanT . Balloon-assisted tracking: a must-know technique to overcome difficult anatomy during transradial approach . Catheter. Cardiovasc. Interv.83 ( 2 ), 211 – 220 ( 2014 ).
  • Deora S , ShahS, PatelT . Balloon-assisted deep intubation of guide catheter for direct thromboaspiration in acute myocardial infarction—a technical report . Int. J. Cardiol.168 ( 1 ), 545 – 547 ( 2013 ).
  • Boukhris M , AzzarelliS, TomaselloSD, ElhadjZI, MarzàF, GalassiAR . The GuideLiner catheter: a useful tool in the armamentarium of the interventional cardiologist . J. Tehran Heart Cent.10 ( 4 ), 208 – 214 ( 2015 ).
  • Kassimis G , RainaT . GuideLiner extension catheter-facilitated side-strut stenting technique for the treatment of right coronary artery ostial in-stent restenosis . Cardiovasc. Revasc. Med.19 ( 1 Pt B ), 133 – 136 ( 2017 ).
  • Luna M , PapayannisA, HolperEM, BanerjeeS, BrilakisES . Transfemoral use of the GuideLiner catheter in complex coronary and bypass graft interventions . Catheter. Cardiovasc. Interv.80 ( 3 ), 437 – 446 ( 2012 ).
  • Kovacic JC , SharmaAB, RoySet al. GuideLiner mother-and-child guide catheter extension: a simple adjunctive tool in PCI for balloon uncrossable chronic total occlusions . J. Interv. Cardiol.26 ( 4 ), 343 – 350 ( 2013 ).
  • Chang YC , FangHY, ChenTH, WuCJ . Left main coronary artery bidirectional dissection caused by ejection of guideliner catheter from the guiding catheter . Catheter. Cardiovasc. Interv.82 ( 3 ), E215 – E220 ( 2013 ).
  • Dauvergne C , ArayaM, UriarteP, NovoaO, NovoaL, MaluendaG . ‘Mother-in-child’ thrombectomy technique: a novel and effective approach to decrease intracoronary thrombus burden in acute myocardial infarction . Cardiovasc. Revasc. Med.14 ( 3 ), 14 – 17 ( 2013 ).
  • Pershad A , SeinV, LauferN . GuideLiner catheter facilitated PCI – a novel device with multiple applications . J. Invasive Cardiol.23 ( 11 ), 254 – 259 ( 2011 ).
  • Bergmann MW . Vascular solutions . Novel Use of the GuideLiner Catheter in Accessing a Tortuous Renal Artery for Renal Denervation ( 2010 ). www.aquilantinterventional.com/assets/aquilantinterventional/Products/papers/871020/ML2280_rev_A_GuideLiner_Case_Report-Dr._Bergmann.pdf .
  • Petrossian G . Vascular solutions . Successful Use of the GuideLiner Catheter to Treat Sequential Distal Carotid Artery Stenosis ( 2010 ). www.aquilantinterventional.com/assets/aquilantinterventional/Products/papers/871020/ML2326_rev_A_GuideLiner_Case_Report-Dr._Petrossian.pdf .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.