Three-dimensional versus two-dimensional ultrasound for fetal nasal bone evaluation in the second trimester

, , , , , & show all
Pages 1432-1437 | Received 28 May 2014, Accepted 12 Aug 2014, Published online: 10 Sep 2014
 

Abstract

Objectives: To compare two-dimensional with three-dimensional ultrasound evaluation of the fetal nasal bone in the second trimester.

Methods: A prospective, non-interventional study was conducted, in 55 singleton fetuses, between 18 and 24 weeks’ gestation. Fetal nasal bone length was measured in the midsagittal plane by two-dimensional imaging and in the midsagittal and coronal plane with three-dimensional ultrasound. All three measurements were compared with one another using one-way repeated samples-measures ANOVA and paired samples t-test.

Results: The average fetal nasal bone length (mean ± SD) as determined by the three methods was 7.01 ± 0.94 mm for the two-dimensional midsagittal, 6.96 ± 1.34 mm for the three-dimensional midsagittal, and 6.98 ± 1.32 mm for the three-dimensional coronal plane; comparisons between one another were not statistically significant. Unilateral hypoplasia and bifid shape of the fetal nasal bone were detected in 8.2% and 20.4% of cases, respectively, by three-dimensional ultrasound, whereas all cases evaded detection with two-dimensional ultrasound (p < 0.001 and p = 0.001, respectively).

Conclusions: Fetal nasal bone length measured with two-dimensional ultrasound does not differ significantly from three-dimensional measurements. However, three-dimensional ultrasound is superior in detecting unilateral nasal bone hypoplasia or absence and in assessing fetal nasal bone shape. Hence, fetal nasal bone examination in the second trimester should include three-dimensional ultrasound evaluation.

Acknowledgements

The authors would like to thank E. Vogiatzopoulou for assistance in data collection, Dr. C. Arnaoutoglou, Dr. A. Karavida and Dr. A. Zavlanos for second trimester nasal bone measurements, I. Dimitrakopoulos Uls Appl. Specialist GE Healthcare for technical consultation, and Professor A. S. Angelidis for statistical consultation.

Declaration of interest

The authors report no conflicts of interest. The authors alone are responsible for the content and writing of this article.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access
  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart
* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.