273
Views
38
CrossRef citations to date
0
Altmetric
Research Article

Sealing effect of hydroxyapatite coating: A 12-month study in canines

, , , &
Pages 563-573 | Published online: 08 Jul 2009

  • Anthony P P, Gie G A, Howie C R, Ling R S. Localised endosteal bone tysis in relation to the femoral components of cemented total hip arthroplasties. J Bone Joint Surg (Br) 1990:72:971-9.
  • Baddeley A J. Gundersen H J, Cruz-Orive L M. Estimation of surface area from vertical sections. J Microsc 1986; 142:259-76.
  • Rechtold J E. Søballe K, Lewis J L, Gustilo R B. The roles of implant motion and particulate polyethylene debris in the formation of an aggressive periprosthetic membrane. In Proceedings of the 41st Annual Meeting Orthopaedic Research Society. Orlando, Florida 1995.
  • Bechtold J E. Søballe K, Wang J Y. Tsukayama D T, Lewis J L, Gustilo R B. Cytokine release: Effects of implant stability, previous implantation, and bone graft. In Proceedings of the 42nd Annual Meeting Orthopaedic Research Society, Atlanta. Georgia 1996.
  • Bechtold J E, Søballe K. Kubic V. Overgaard S, Lewis J L, Gustilo R B. Synergy between implant motion and particulate polyethylene in the formation of an aggressive periprosthetic membrane. In Proceedings of the 43rd Annual Meeting Orthopaedic Research Society. San Francisco. California 1997.
  • Bloebaum R D. Becks D. Dorr L. D, Savory C G. DuPont J A. Hofmann A A. Complications with hydroxyapatite particulate separation in total hip arthroplasty. Clin Orthop 1994:298: 19-26.
  • Bloebaum R D, Zou L, Bachus K N, Shea K G, Hofmann A A. Dunn H K. Analysis of particles in acetabular components from patients with osteolysis. Clin Orthop 1997: 338: 109-118.
  • Bobyn J D, Jacobs J J. Tanzer M. Urban R M, Arihindi R. Sumner D R. Turner T M. Brooks C E. The susceptibility of smooth implant surfaces to perümplant fibrosis and migration of polyethylene wear debris. Clin Orthop 1995:311: 21-39.
  • Bos I, Johannisson R. Lohrs U. Lindner B, Seydel U. Com parative investigations of regional lymph nodes and pseudocapsules after implantation of joint endoprostheses. Pathol Res Pract 1990; 186: 707-16.
  • Capello W N, D' Antonio J A. Manley M T. Feinberg J R. Hydroxyapatite in total hip arthroplasty. Clinical results and critical issues. Clin Orthop 1998; 355: 200-11.
  • Case C P. Langkamer V G. James C. Palmer M R. Kemp A J. Heap P F. Solomon L. Widespread dissemination of metal debris from implants. J Bone Joint Surg (Br) 1994: 76:701-12.
  • Case C P. Langkamer V G. Howell R T. Webb J. Standen G. Palmer M, Kemp A, Learmonth I D. Preliminary observations on possible premalignant changes in bone marrow adjacent to worn total hip arthroplasty implants. Clin Orthop (Suppl 329) 1996: 269-79
  • Crawford R W, Evans K. Ling R S. Murray D W. Fluid flow around model femoral components of differing surface finishes. Acta Orthop Scand 1999: 70 (6): 589-95.
  • D'Antonio J A. Capello W N, Manley M T. Remodeling of bone around hydroxyapalitc-coaled femoral stems. J Bone Joint Surg (Am) 1996: 78: 1226-34.
  • Geesink R. Hoefnagels N. Eight years' results of HA-coaled primary total hip replacement. Acta Orthop BeIg (Suppl 1) 1997: 63:72-5.
  • Gillespie W J. Henry D A. O'Connell D L, Kendrick S. Juszczak K. Mclnneny K, Derby L. Development of hematopoietic cancers after implantation of total joint replacement. Clin Orthop (Suppl 329) 1996: 290-6.
  • Gillespie W J. Frampton C M. Henderson R J. Ryan P M. The incidence of cancer following total hip replacement. J Bone Joint Surg (Br) 1998: 70: 539-42.
  • Gundersen H J. Bendtsen T F. Korbo L. Marcussen N, Mpller A, Nielsen K. Nyengaard J R. Pakkenberg B. Sø rensen F B. Veslerby A et al. Some new, simple and efficient stereological methods and their use in pathological research and diagnosis. APMlS 1988; 96: 379-94.
  • Hieks D G. Judkins A R, Sickel J Z, Rosier R N. Puzas J E. O'Keefe R J. Granular histiocytosis of pelvic lymph nodes following total hip arthroplasty. The presence of wear debris, cytokine production, and immunologicallyactivated macrophages. J Bone Joint Surg (Am) 1996: 78: 482-96.
  • Horowitz S M. Gonzales J B. Inflammatory response to implant particulars in a macrophagc/osteoblast coculture model. Calcif Tissue Int 1996; 59: 392-6.
  • Huwie D W, Vernon Roberts B, Oakeshott R, Manthey B. A rat model of resorption of bone at the cement-hone interface in the presence of polyethylene wear particles. J Bone Joint Surg (Am) 1988; 70: 257-63.
  • Kärrholm J. Malchau H. Snorrason H Herberts P. Rorabeck C H. Bourne R B, Laupacis A, Feeny D. Wong C. Tugwell P. Leslie K. Bullas R. Micromotion of femoral stems in total hip arthroplasty. J Bone Joint Surg (Am) 1994a;76: 156-64.
  • Kärrholm J. Borssen B, Löwenhielm G, Snorrason F. Does early micromotion of femoral stem prostheses matter'? 4-7-year stereoradiographic follow-up of 84 cemented poslhescs. J Bone Joint Surg (Br) 1994b; 76: 912-7.
  • Kraemer W J, Maistrelli G L, Fomasier V. Binnington A. Zhao J F. Migration of polyethylene wear debris in hip arthroplasties: a canine model. J Appl Biomatrr 1995: 6: 225-30.
  • Langkamer V G, Case C P, Heap P. Taylor A, Collins C. Pearse M. Solomon L. Systemic distribution of wear debris after hip replacement. A cause for concern? J Bone Joint Surg (Br) 1992:74:831-9.
  • McKellop H A, Campbell P, Park S H. Schmalzried T P. Grigoris P. Amstutz H C, Sarmiento A. The origin of submicron polyethylene wear debris in total hip arthroplasly. Clin Orthop 1995; 311: 3-20.
  • Mirra J M. Amstutz H C. Matos M. Gold R. The pathology of the joint tissues and its clinical relevance in prosthesis failure. Clin Orthop 1976: 117: 221-40.
  • Moilancn T. Stocks G W. Freeman M A. Scott G. Goodier W D. Evans S J. Hydroxyapatite coating of an acetabular prosthesis. Effect on stability. J Bone Joint Surg (Br) 1996: 78: 200-5.
  • Nivbrant B, Karlsson K. Kärrholm J. Cycokine levels in synovial fluid from hips with well-functioning or loose prostheses. J Bone Joint Surg (Br) 1999:81:163-6.
  • Overgaard S. Lmd M. Rahbek O. Btinger C, Söballc K. Improved fixation of porous-coated versus grit-blasted surface texture of hydroxyapatite-coated implants in dogs. Acta Orthop Scand 1997: 68: 337-43.
  • Overgaard S. Lind M, Josephsen K. Maunsbach A, Bünger C. Søballe K. Resorption of hydroxyapatite and fluorapatitc ceramic coatings on weight-bearing implants: A quantitative and morphological stxidy in dogs. J Biomed Maler Res 1998; 39, 141-52.
  • Overgaard S. Søballe K. Jørgen H, Gundersen G. Efficiency of systematic sampling in histomorphometric bone research illustrated by hydroxyapatite-coated implants: optimizing the stereological vertical-section design. J Orthop Res 2000: 18: 313-21.
  • Piolelti D P, Takei H. Kwon S Y, Wood D. Sung K L. The cylotoxic effect of titanium particles phagocytosed by osteoblasts. J Biomed Mater Res 1999: 46: 399-407.
  • Rahbek O, Overgaard S. Søballe K, Bünger C. Hydroxyapalile coating might prevent peri-implant particle migration: a pilot study in dogs. Acta Orthop Scand 1996: 67: 58-9.
  • Rahbek O, Overgaard S. Bendix K. Lind M, Bünger C. Søballe K. Scaling effect of hydroxyapalite coating on peri-implant particle migration. Accepted by J Bone Joint Surg (Br).
  • Salvati E A. Betts F. Doty S B. Particulate metallic debris in cemented total hip arthroplasty. Clin Orthop 1993: 8: 160-73.
  • Schmalzried T P, Jasty M, Harris W H. Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. J Bone Joim Surg (Am) 1992: 74: 849-63.
  • Shanbhag A S. Jacobs J J, Glant TT. Gilbert J L. Black J. Galante J O. Composition and morphology of wear debris in failed uncemented total hip replacement. J Bone Joint Surg (Br) 1994: 76: 60-7.
  • Søballe K. Hydroxyapatite ceramic coating for bone implant fixation. Mechanical and histological studies in dogs. Acta Orthop Scand (Suppl 255) 1993: 1 58.
  • Søballc K. Hansen F. S, Brockstedt Rasnussen M. Hjortdal V E. Juhl G I. Pedersen C M. Hvid I. Bünger C. Gap healing enhanced by hydroxyapatite coaling in dogs. Clin Orthop 1991:272:300-7.
  • Süballe K. Hansen E S. Rasmussen H B. Jørgensen P H. Billiger C. Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions. J Orthop Res 1992; 10: 285-99.
  • Søballe K, Hansen E S, Brockstedt Rasmussen H, Bünger C. Hydroxyapatite coating converts fibrous tissue to bone around loaded implants. J Bone Joint Surg (Be) 1993a:75: 270-8.
  • Søballe K, Toksvig Larsen S, Gelineck J. Fruensgaard S. Hansen E S. Ryd L, Lucht U, Bünger C. Migration of hydroxyapatite-coated femoral prostheses. A roentgen stereophotogrammetric study. J Bone Joint Surg (Br) 1993b; 75:681-7.
  • van der Vis Il M, Marti R K. Tigchelaar W, Schuller H M, van Noorden C J. Benign cellular responses in rays to different wear particles in intraarticular and intramedullary environment. J Bone Joint Surg (Br) 1997; 79: 837-43.
  • Visuri T. Koskenvuo M. Cancer risk after Mckee-Farrar total hip replacement. Orthopedics 1991; 14: 137-42.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.