583
Views
71
CrossRef citations to date
0
Altmetric
Research Article

HA particles can be released from well-fixed HA-coated stems

, &
Pages 298-306 | Published online: 08 Jul 2009

REFERENCES

  • Agins H J, Alcock N W, Bansal M, Salvati E A, Wilson P D Jr, Pellicci P M, Bullough P G. Metallic wear in failed titanium-alloy total hip replacements. A histological and quantitative analysis. J Bone Joint Surg (Am) 1988; 70 (3): 347–56.
  • Amstutz H C, Nasser S, More R C, Kabo J M. The anthro-pometric total hip femoral prosthesis. Preliminary clinical and roentgenographic findings of exact-fit cementless application. Clin Orthop 1989; 242: 104–19.
  • Bauer T W, Geesink R C, Zimmerman R, McMahon J T. Hydroxyapatite-coated femoral stems. Histological analysis of components retrieved at autopsy. J Bone Joint Surg (Am) 1991; 73 (10): 1439–52.
  • Bauer T W, Stulberg B N, Ming J, Geesink R G. Unce-mented acetabular components. Histologic analysis of retrieved hydroxyapatite-coated and porous implants. J Arthroplasty 1993; 8 (2): 167–77.
  • Bloebaum R D, Beeks D, Don L D, Savory C G, DuPont J A, Hofmann AA. Complications with hydroxyapatite par-ticulate separation in total hip arthroplasty. Clin Orthop 1994; 298: 19–26.
  • Bloebaum R D, Zou L, Bachus K N, Shea K G, Hofmann A A, Dunn H K. Analysis of particles in acetabular com-ponents from patients with osteolysis. Clin Orthop 1997; 338: 109–18.
  • Buma P. Gardeniers J W. Tissue reactions around a hydroxy-apatite-coated hip prosthesis. Case report of a retrieved specimen. J Arthroplasty 1995; 10 (3): 389–95.
  • Coathup M J, Blunn G W, Flynn N, Williams C, Thomas N P. A comparison of bone remodelling around hydroxyapa - tite-coated, porous-coated and grit-blasted hip replace-ments retrieved at post-mortem. J Bone Joint Surg (Br) 2001; 83 (1): 118–23.
  • Collier J P, Surprenant VA, Mayor M B, Wrona M, Jensen R E, Surprenant H P. Loss of hydroxyapatite coating on retrieved, total hip components. J Arthroplasty 1993; 8 (4): 389–93.
  • de Groot K, Geesink R, Klein C P, Serekian P. Plasma-sprayed coatings of hydroxylapatite. J Biomed Mater Res 1987; 21(12): 1375–81.
  • DeLee J G, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 1976; 121: 20–32.
  • Donath K. Preparation of histologic sections by the cutting-grinding technique for hard tissue and other material not suitable to be sectioned by routine methods. Equipment and methodical performance. EXACT-Kulzer-Publica-tion, Norderstedt 1993.
  • Ducheyne P. Cuckler J M. Bioactive ceramic prosthetic coat-ings. Clin Orthop 1992; 276: 102–14.
  • Furlong R J, Osborn J F. Fixation of hip prostheses by hydroxyapatite ceramic coatings. J Bone Joint Surg (Br) 1991; 73: 741–5.
  • Geesink R G, Hoefnagels N H. Six-year results of hydroxy-apatite-coated total hip replacement. J Bone Joint Surg (Br) 1995; 77 (4): 534–47.
  • Geesink R G, de Groot K, Klein C P. Chemical implant fixa-tion using hydroxyl-apatite coatings. The development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates. Clin Orthop 1987; 225: 147–70.
  • Gruen T A, McNeice G M, Amstutz H C. "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 1979; 141: 17–27.
  • Hardinge K. The direct lateral approach to the hip. J Bone Joint Surg (Br) 1982; 64 (1): 17–9.
  • Hardy D C, Frayssinet P, Guilhem A, Lafontaine M A, Delince P E. Bonding of hydroxyapatite-coated femoral prostheses. Histopathology of specimens from four cases. J Bone Joint Surg (Br) 1991; 73: 732–40.
  • Hardy D C, Frayssinet P, Bonel G, Authom T, Le Naelou S A, Delince P E. Two-year outcome of hydroxyapatite - coated prostheses. Two femoral prostheses retrieved at autopsy. Acta Orthop Scand 1994; 65 (3): 253–7.
  • Johnston R C, Fitzgerald R H J, Harris W H, Poss R, Muller M E, Sledge C B. Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results. J Bone Joint Surg (Am) 1990; 72(2): 161–8.
  • Kadoya Y, Kobayashi A, Ohashi H. Wear and osteolysis in total joint replacements. Acta Orthop Scand (Suppl 278) 1998; 69: 1–16.
  • Kärrholm J, Malchau H, Snorrason F, Herberts P. Micro-motion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated and porous-coated stems with roentgen stereophotogram - metric analysis. J Bone Joint Surg (Am) 1994; 76 (11): 1692–1705.
  • Lausmaa J, Carlsson L, Möller K, Rolckum M. Analysis of abnormal wear in UHMWPE acetabular cups. Proc. 14th European Conference on Biomaterials, Hague, 1998.
  • Lemons J E. Hydroxyapatite coatings. Clin Orthop 1988; 235: 220–3.
  • Lintner F, Bohm G, Huber M, Scholz R. Histology of tissue adjacent to an HAC-coated femoral prosthesis. A case report. J Bone Joint Surg (Br) 1994; 76 (5): 824–30.
  • McNally S A, Shepperd J A, Mann C V, Walczak J P. The results at nine to twelve years of the use of a hydroxyapa-tite-coated femoral stem. J Bone Joint Surg (Br) 2000; 82(3): 378–82.
  • Moilanen T, Stocks G W, Freeman M A, Scott G, Goodier W D, Evans S J. Hydroxyapatite coating of an acetabular prosthesis. Effect on stability. J Bone Joint Surg (Br) 1996; 78 (2): 200–5.
  • Morscher E W. Hydroxyapatite coating of prostheses. J Bone Joint Surg (Br) 1991; 73 (5): 705–6.
  • Morscher E W, Hefti A, Aebi U. Severe osteolysis after third-body wear due to hydroxyapatite particles from acetabular cup coating. J Bone Joint Surg (Br) 1998; 80 (2): 267–72.
  • Overgaard S, Lind M, Rahbek 0, Biinger C, Soballe K. Improved fixation of porous-coated versus grit-blasted surface texture of hydroxyapatite-coated implants in dogs. Acta Orthop Scand 1997; 68 (4): 337–43.
  • Overgaard S, Lind M, Glerup H, Biinger C, Soballe K. Porous-coated versus grit-blasted surface texture of hydroxyapatite-coated implants during controlled micro-motion. Mechanical and histomorphometric results. J Arthroplasty 1998; 13 (4): 449–58.
  • Rolckum M, Reigstad A. Polyethylene wear with an entirely HA-coated total hip replacement. 79 hips followed for 5 years. Acta Orthop Scand 1998; 69 (3): 253–8.
  • Rolckum M, Reigstad A. Total hip replacement with an entirely hydroxyapatite-coated prosthesis. 5 years' follow-up of 94 consecutive hips. J Arthroplasty 1999; 14 (6): 689–700.
  • ROlckum M, Brandt M, Bye K, Hetland K R, Waage S, Reigstad A. Polyethylene wear, osteolysis and acetabular loosening with an HA-coated hip prosthesis. A follow-up of 94 consecutive arthroplasties. J Bone Joint Surg (Br) 1999; 81(4): 582–9.
  • Schmalzried T P, Jasty M, Harris W H. Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. J Bone Joint Surg (Br) 1992; 74 (6): 849–63.
  • Soballe K, Hansen E S, Brockstedt-Rasmussen H, Hjortdal V E, Juhl G I, Hvid I, Biinger C. Gap healing enhanced by hydroxyapatite coating in dogs. Clin Orthop 1991; 272: 300–7.
  • Soballe K, Hansen E S, Brockstedt-Rasmussen H, Biinger C. Hydroxyapatite coating converts fibrous tissue to bone around loaded implants. J Bone Joint Surg (Br) 1993; 75 (2): 270–8.
  • Thanner J, Kärrholm J, Herberts P, Malchau H. Porous cups with and without hydroxylapatite-tricalcium phosphate coating: 23 matched pairs evaluated with radiostereom - etry. J Arthroplasty 1999; 14 (3): 266–71.
  • Tonino A J, Rahmy A I. The hydroxyapatite-ABG hip system: 5- to 7-year results from an international mul-ticentre study. The International ABG Study Group. J Arthroplasty 2000; 15 (3): 274–82.
  • Tonino A J, Therin M, Doyle C. Hydroxyapatite-coated femoral stems. Histology and histomorphometry around five components retrieved at post mortem. J Bone Joint Surg (Br) 1999; 81(1): 148–54.
  • Wang B C, Lee TM, Chang E, Yang C Y. The shear strength and the failure mode of plasma-sprayed hydroxyapatite coating to bone: the effect of coating thickness. J Biomed Mater Res 1993; 27: 1315–27.
  • Zicat B, Engh C A, Gokcen E. Patterns of osteolysis around total hip components inserted with and without cement. J Bone Joint Surg (Am) 1995; 77 (3): 432–9.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.