46
Views
8
CrossRef citations to date
0
Altmetric
Otoneurology

Comparison of the Implantability of Electronic Hearing Devices in a Virtual Reality Planning Environment and in Human Temporal Bones

, , , , &
Pages 1039-1045 | Received 21 Jan 2004, Accepted 29 Jan 2004, Published online: 08 Jul 2009

References

  • Dormer KT, Gan RZ. Biomaterials for implantable middle ear hearing devices. Otolaryngol Clin North Am 2001; 34: 289–97.
  • Jaffee IS. Implantable middle ear hearing devices: Food and Drug Administration review process. Otolaryngol Clin North Am 2001; 34: 515–7.
  • Hiittenbrink KB. Current status and critical reflections on implantable hearing aids. Am J Otol 1999; 20: 409–15.
  • Kasic JF, Fredrickson JM. The Otologics MET ossicular stimulator. Otolaryngol Clin North Am 2001; 34: 501–13.
  • Yanagihara N, Sato H, Hinohira Y, Gyo K, Hon i K. Long-term results using a piezoelectric semi-implantable middle ear hearing device: the Rion Device E-type. Otolaryngol Clin North Am 2001; 34: 389–400.
  • Luetje CM, Brackman D, Balkany TJ, Maw J, Baker RS, Kelsall D, et al. Phase III clinical trial results with the Vibrant Soundbridge implantable middle ear hearing device: a prospective controlled multicenter study. Oto-laryngol Head Neck Surg 2002; 126: 97–107.
  • Hough JV, Dyer RK Jr, Matthews P, Wood MW. Semi-implantable electromagnetic middle ear hearing device for moderate to severe sensorineural hearing loss. Otolaryngol Clin North Am 2001; 34: 401–16.
  • Zenner HP, Leysieffer H. Total implantation of the Implex TICA hearing amplifier implant for high-frequency sensorineural hearing loss. Otolaryngol Clin North Am 2001; 34: 417–46.
  • Roland PS, Shoup AG, Shea MC, Richey HS, Jones DB. Verification of improved patient outcomes with a partially implantable hearing aid, the SOUNDTEC direct hearing system. Laryngoscope 2001; 111: 1682–6.
  • Hough JV, Dyer RK Jr, Matthews P, Wood MW Early clinical results: SOUNDTEC implantable hearing device phase II study. Laryngoscope 2001; 111: 1–8.
  • Fraysse B, Lavieille JP, Schmerber S, Enee V, Truy E, Vincent C, et al. A multicenter study of the Vibrant Soundbridge middle ear implant: early clinical results and experience. Otol Neurootol 2001; 22: 952–61.
  • Maassen MM, Lehner R, Leysieffer H, Baumann I, Zenner HP. Total implantation of the active hearing implant TICA for middle ear disease: a temporal bone study. Ann Otol Rhinol Laryngol 2001; 110: 912–6.
  • Maniglia AJ, Murray G, Arnold JE, Ko WH. Bioelec-tronic microphone options for a totally implantable hearing device for partial and total hearing loss. Otolaryngol Clin North Am 2001; 34: 469–83.
  • Snik AF, Cremers CW. Vibrant semi-implantable hear-ing device with digital sound processing: effective gain and speech perception. Arch Otolaryngol Head Neck Surg 2001; 127: 1433–7.
  • Ko WH, Zhu WL, Kane M, Maniglia AJ. Engineering principles applied to implantable otologic devices. Oto-laryngol Clin North Am 2001; 34: 299–314.
  • Snik AF, Mylanus EA, Cremers CW, Dillier N, Fisch U, Gnadeberg D, et al. Multicenter audiometric results with the Vibrant Soundbridge, a semi-implantable hear-ing device for sensorineural hearing impairment. Oto-laryngol Clin North Am 2001; 34: 373–88.
  • Hiittenbrink KB, Zahnert TH, Bornitz M, Hofmann G. Biomechanical aspects in implantable microphones and hearing aids and development of a concept with a hydroacoustical transmission. Acta Otolaryngol 2001; 121: 185–9.
  • Fisch U, Cremers CW, Lenarz T, Weber B, Babighian G, Uziel AS, et al. Clinical experience with the Vibrant Soundbridge implant device. Otol Neurootol 2001; 22: 962–72.
  • Maher N, Becker NH, Laszig R. Quantifizierung relevanter MessgröBen des Felsenbeins im Computerto-mogramm vor Cochlear-Implant-Operation. Laryngor-hinootologie 1995; 74: 337–42.
  • Arriaga M, Curtin H, Takahashi H, Hirsch BE, Kamerer DB. Staging proposal for external auditory meatus carcinoma based on preoperative clinical exam-ination and computed tomography finding. Ann Otol Rhinol Laryngol 1990; 99: 714–21.
  • Gunlock MG, Gentry LR. Anatomy of the temporal bone. Neuroimaging Clin North Am 1998; 8: 195–209.
  • Reisser C, Schubert O, Forsting M, Sartor K. Anatomy of the temporal bone: detailed three-dimensional display based on image data from high-resolution helical CT—a preliminary report. Am J Otol 1996; 17: 473–9.
  • Maassen MM, Lüdtke R, Dammann F, Zenner HP. Value of Schuller conventional röntgen diagnosis and computerized tomography of the temporal bone in preoperative diagnosis of the Tübingen implantable cochlear amplifier. HNO 1998; 46: 220–7.
  • Lehner R, Brugger H, Maassen MM, Zenner HP. A totally implantable drug delivery system (TI-DDS) for local therapy of the middle and inner ear. Ear Nose Throat J 1997; 8: 567–70.
  • Dammann F, Bode A, Schwaderer E, Schaich M, Heuschmid M, Maassen M. Computer-aided surgical planning for implantation of hearing aids based on CT data in a VR environment. RadioGraphics 2001; 21: 183–90.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.