178
Views
23
CrossRef citations to date
0
Altmetric
FLOW AND SEQUENTIAL INJECTION—GENERAL APPROACHES

Direct Solid-Phase Optical Measurements in Flow Systems: A Review

, &
Pages 528-559 | Received 13 Mar 2010, Accepted 05 May 2010, Published online: 18 Feb 2011

REFERENCES

  • Alava-Moreno , F. , M. Diaz-Garcia , and A. Sanz-Medel . 1993 . Room-temperature phosphorescence optosensor for tetracyclines . Anal. Chim. Acta 281 : 637 – 644 .
  • Albero , M. I. , J. A. Ortuño , M. S. García , C. Sanchez-Pedreño , and R. Expósito . 2002 . Determination of zinc (II) in pharmaceuticals based on a flow-through bulk optode . J. Pharm. Biomed. Anal. 29 : 779 – 786 .
  • Alcudia-León , M. C. , R. Lucena , S. Cárdenas , and M. Valcárcel . 2008 . Characterization of an attenuated total reflection-based sensor for integrated solid-phase extraction and infrared detection . Anal. Chem. 80 : 1146 – 1151 .
  • Amini , M. K. , T. Momeni-Isfahani , J. H. Khorasania , and M. Pourhossein . 2004 . Development of an optical chemical sensor based on 2-(5-bromo-2-pyridylazo)-5-(diethylamino)phenol in Nafion® for determination of nickel ion . Talanta 63 : 713 – 720 .
  • Armenta , S. , S. Garrigues , and M. de la Guardia . 2005 . Solid-phase FT-Raman determination of caffeine in energy drinks . Anal. Chim. Acta 547 : 197 – 203 .
  • Armenta , S. , and B. Lendl . 2009 . Flow through FTIR sensor based on solid phase spectroscopy (SPS) on conventional octadecyl (C18) silica . Vib. Spectrosc. 51 : 60 – 64 .
  • Ayora-Cañada , M. J. , M. I. Pascual-Reguera , and A. Molina-Díaz . 1998 . Continuous flow-through solid phase spectrophotometric determination of trace amounts of zinc . Anal. Chim. Acta 375 : 71 – 80 .
  • Ayora-Cañada , M. J. , M. I. Pascual Reguera , and A. Molina-Díaz . 1999 . An integrated reaction-retention and spectrophotometric detection flow system for the determination of nickel . Fresenius J. Anal. Chem. 363 : 59 – 63 .
  • Ayora-Cañada , M. J. , M. I. Pascual-Reguera , and A. Molina-Díaz . 2000 . Determination of vanadium by solid phase spectrophotometry in a continuous flow system . Intern. J. Environ. Anal. Chem. 76 : 319 – 330 .
  • Ayora-Cañada , M. J. , M. I. Pascual Reguera , A. Molina-Díaz , and L. F. Capitán-Vallvey . 1999 . Solid-phase UV spectroscopic multisensor for the simultaneous determination of caffeine, dimenhydrinate and acetaminophen by using partial least squares multicalibration . Talanta 49 : 691 – 701 .
  • Baliza , P. X. , S. L. C. Ferreira , and L. S. G. Teixeira . 2009 . Application of pyridylazo and thiazolylazo reagents in flow injection preconcentration systems for determination of metals . Talanta 79 : 2 – 9 .
  • Calatayud , J. M. 1996. Flow Injection Analysis of Pharmaceuticals: Automation in the Laboratory . Taylor and Francis : London.
  • Capitan-Vallvey , L. F. , M. C. Valencia , and G. Miron . 1994 . Flow-injection method for the determination of tin in fruit juices using solid-phase spectrophotometry . Anal. Chim. Acta 289 : 365 – 370 .
  • Cassella , R. J. , L. S. G. Teixeira , S. Garrigues , A. C. S. Costa , R. E. Santelli , and M. de la Guardia . 2000 . Determination of sulfide in waters by flow-injection solid phase spectrophotometry . Analyst 125 : 1835 – 1838 .
  • Chen , J. , and J. Bai . 2008 . Chemiluminescence flow sensor with immobilized reagent for the determination of pyrogallol based on potassium hexacyanoferrate(III) oxidation . Spectrochim. Acta A 71 : 989 – 992 .
  • Coo , L. D. , and I. S. Martinez . 2004 . Nafion®-based optical sensor for the determination of selenium in water samples . Talanta 64 : 1317 – 1322 .
  • Domínguez-Vidal , A. , J. F. Garcia-Reyes , P. Ortega-Barrales , and A. Molina-Diaz . 2002a . UV spectrophotometric flow-through multiparameter sensor for the simultaneous determination of acetaminophen, acetylsalicylic acid, and caffeine . Anal. Lett. 35 : 2433 – 2447 .
  • Domínguez-Vidal , A. , P. Ortega-Barrales , and A. Molina-Diaz . 2002b . Fast flow-injection fluorimetric determination of amiloride by using a solid sensing zone . Talanta 56 : 1005 – 1013 .
  • Domínguez-Vidal , A. , P. Ortega-Barrales , and A. Molina-Díaz . 2007 . Environmental water samples analysis of pesticides by means of chemometrics combined with fluorimetric multioptosensing . J. Fluoresc. 17 : 271 – 277 .
  • Fang , Y. , S. Yan , B. Ning , N. Liu , Z. Gao , and F. Chao . 2009 . Flow injection chemiluminescence sensor using molecularly imprinted polymers as recognition element for determination of maleic hydrazide . Biosens. Bioeletron. 24 : 2323 – 2327 .
  • Fernández de Córdova , M. L. , P. Ortega-Barrales , G. Rodríguez-Torné , and A. Molina-Díaz . 2003 . A flow injection sensor for simultaneous determination of sulfamethoxazole and trimethoprim by using Sephadex SP C-25 for continuous on-line separation and solid phase UV transduction . J. Pharm. Biomed. Anal. 31 : 669 – 677 .
  • Ferreira , S. L. C. , N. M. L. Araujo , A. B. Santos , A. F. Dantas , and A. C. S. Costa . 1995 . Spectrophotometric determination of zinc in copper-base alloys with TAN . Microchim. Acta 118 : 123 – 129 .
  • Ferrer , L. , G. Armas , M. Miró , J. M. Estela , and V. Cerdà . 2005a . Flow-through optical fiber sensor for automatic sulfide determination in waters by multisyringe flow injection analysis using solid-phase reflectometry . Analyst 130 : 644 – 651 .
  • Ferrer , L. , G. Armas , M. Miró , J. M. Estela , and V. Cerdà . 2005b . Interfacing in-line gas-diffusion separation with optrode sorptive preconcentration exploiting multisyringe flow injection analysis . Talanta 68 : 343 – 350 .
  • Ferrer , L. , J. M. Estela , and V. Cerdà . 2006 . A smart multisyringe flow injection system for analysis of sample batches with high variability in sulfide concentration . Anal. Chim. Acta 573–574: 391–398 .
  • Flores , J. L. , A. M. Diaz , and M. L. Fernández de Córdova . 2007 . Development of a photochemically induced fluorescence-based optosensor for the determination of imidacloprid in peppers and environmental waters . Talanta 72 : 991 – 997 .
  • Flores , J. L. , M. L. Fernández de Córdova , and A. Molina-Díaz . 2007 . Flow-through optosensor combined with photochemically induced fluorescence for simultaneous determination of binary mixtures of sulfonamides in pharmaceuticals, milk and urine . Anal. Chim. Acta 600 : 164 – 171 .
  • Frenzel , W. , and S. Krekler . 1995 . Spectrophotometric determination of total phenolics by solvent extraction and sorbent extraction optosensing using flow injection methodology . Anal. Chim. Acta 310 : 437 – 446 .
  • García , S. , I. Albero , J. A. Ortuño , and C. Sanchez-Pedreño . 2003. Flow-through bulk optode for the spectrophotometric determination of perchlorate. Microchim. Acta 143: 59–63.
  • García-Reyes , J. F. , B. Gilbert-López , and A. Molina-Díaz . 2009 . Flow-through solid-phase spectroscopy: A contribution to green analytical chemistry . Spectrosc. Lett. 42 : 383 – 393 .
  • Garcia-Reyes , J. F. , E. J. Llorent-Martínez , P. Ortega-Barrales , and A. Molina-Díaz . 2004 . Multiwavelength fluorescence based optosensor for simultaneous determination of fuberidazole, carbaryl and benomyl . Talanta 64 : 742 – 749 .
  • Garcia-Reyes , J. F. , E. J. Llorent-Martínez , P. Ortega-Barrales , and A. Molina-Díaz . 2006 . Determination of thiabendazole residues in citrus fruits using a multicommutated fluorescence-based optosensor . Anal. Chim. Acta 557 : 95 – 100 .
  • García-Reyes , J. F. , P. Ortega Barrales , and A. Molina Díaz . 2003 . Gel-surface enhanced fluorescence sensing system coupled to a continuous-flow assembly for simultaneous monitoring of benomyl and carbendazim . Anal. Chim. Acta 493 : 35 – 45 .
  • Garcia-Reyes , J. F. , P. Ortega-Barrales , and A. Molina-Díaz . 2004 . Development of a single fluorescence-based optosensor for rapid simultaneous determination of fungicides benomyl and thiabendazole in waters and commercial formulations . J. Agric. Food Chem. 52 : 2197 – 2202 .
  • Garrigues , S. , M. T. Vidal , M. Gallignani , and M. de la Guardia . 1994 . On-line preconcentration and flow analysis-Fourier transform infrared determination of carbaryl . Analyst 119 : 659 – 664 .
  • Ge , S. , M. Yan , X. Cheng , C. Zhang , J. Yu , P. Zhao , and W. Gao . 2010 . On-line molecular imprinted solid-phase extraction flow-injection fluorescence sensor for determination of florfenicol in animal tissues . J. Pharm. Biomed. Anal. 52 : 615 – 619 .
  • Haberkorn , M. , P. Hinsmann , and B. Lendl . 2002 . A mid-IR flow-through sensor for direct monitoring of enzyme catalysed reactions. Case study: Measurement of carbohydrates in beer . Analyst 127 : 109 – 113 .
  • Jerónimo , P. , A. Araujo , M. Montenegro , C. Pasquini , and I. Raimundo . 2004 . Direct determination of copper in urine using a sol-gel optical sensor coupled to a multicommutated flow system . Anal. Bioanal. Chem. 380 : 108 – 114 .
  • Lazaro F. , M. D. Luque de Castro , and M. Valcárcel . 1989 . Integrated retention/spectrophotometric detection in flow-injection analysis. Determination of iron in water and wine . Anal. Chim. Acta 219 : 231 – 238 .
  • Lendl , B. , and R. Schindler . 1999 . Flow-through sensors enhancing sensitivity and selectivity of FTIR spectroscopy in aqueous media . Vibrat. Spectrosc. 19 : 1 – 10 .
  • Llorent-Martínez , E. J. , A. Domínguez-Vidal , P. Ortega-Barrales , M. de la Guardia , and A. Molina-Diaz . 2005 . Implementation of multicommutation principle with flow-through multioptosensors . Anal. Chim. Acta 545 : 113 – 118 .
  • Llorent-Martínez , E. J. , J. F. García-Reyes , P. Ortega-Barrales , and A. Molina-Díaz . 2005 . Terbium-sensitized luminescence optosensor for the determination of norfloxacin in biological fluids . Anal. Chim. Acta 532 : 159 – 164 .
  • Llorent-Martínez , E. J. , P. Ortega-Barrales , M. L. Fernández de Córdova , and A. Ruiz-Medina . 2009 . Development of an automated chemiluminescence flow-through sensor for the determination of 5-aminosalicylicacid in pharmaceuticals: A comparative study between sequential and multicommutated flow techniques . Anal. Bioanal. Chem. 394 : 845 – 853 .
  • Llorent-Martínez , E. J. , P. Ortega-Barrales , and A. Molina-Diaz . 2006 . Multi-commutated flow-through multi-optosensing: A tool for environmental analysis . Spectrosc. Lett. 39 : 619 – 629 .
  • Llorent-Martínez , E. J. , P. Ortega-Barrales , and A. Molina-Diaz . 2008 . Sequential injection multi-optosensor based on a dual-luminescence system using two sensing zones: Application to multivitamin determination . Microchim. Acta 162 : 199 – 204 .
  • Lopez-Flores , J. , M. L. Fernández de Córdova , and A. Molina-Diaz . 2005. Implementation of flow-through solid phase spectroscopic transduction with photochemically induced fluorescence: Determination of thiamine. Anal. Chim. Acta 535: 161–168.
  • Luque de Castro , M. D. 1992 . Solid-phase reactors in flow injection analysis . Trends Anal. Chem. 11 : 149 – 155 .
  • Mar , J. L. G. , L. L. Martínez , P. L. L. Alba , J. E. C. Durán , and V. C. Martín . 2006 . Optical fiber reflectance sensor coupled to a multisyringe flow injection system for preconcentration and determination of 1-naphthylamine in water samples . Anal. Chim. Acta 573–574: 406–412 .
  • Matsuoka , S. , and K. Yoshimura . 2010 . Recent trends in solid phase spectrometry: 2003–2009. A Review . Anal. Chim. Acta 664 : 1 – 18 .
  • Miró , M. , W. Frenzel , J. M. Estela , and V. Cerda . 2001 . A novel flow-through disk-based solid-phase extraction diffuse reflectance optrode. Application to preconcentration and determination of trace levels of nitrite . Analyst 126 : 1740 – 1746 .
  • Molina-Díaz , A. , A. Ruiz-Medina , and M. L. Fernández de Córdova . 2002 . The potential of flow-through optosensors in pharmaceutical analysis . J. Pharm. Biomed. Anal. 28 : 399 – 419 .
  • Ortega-Barrales , P. , M. J. Ayora-Cañada , A. Molina-Diaz , S. Garrigues , and M. de la Guardia . 1999 . Solid phase Fourier transform near infrared spectroscopy . Analyst 124 : 579 – 582 .
  • Ortega-Barrales , P. , A. Ruiz-Medina , M. L. Fernández de Córdova , and A. Molina-Díaz . 2002 . A flow-through solid-phase spectroscopic sensing device implemented with FIA solution measurements in the same flow cell: Determination of binary mixtures of thiamine with ascorbic acid or acetylsalicylic acid . Anal. Bioanal. Chem. 373 : 227 – 232 .
  • Piccirilli , G. , and G. Escandar . 2009 . Flow injection analysis with on-line nylon powder extraction for room-temperature phosphorescence determination of thiabendazole . Anal. Chim. Acta 646 : 90 – 96 .
  • Pons , C. , R. Forteza , and V. Cerdà . 2004 . Expert multi-syringe flow-injection system for the determination and speciation analysis of iron using chelating disks in water samples . Anal. Chim. Acta 524 : 79 – 88 .
  • Pons , C. , R. Forteza , and V. Cerdà . 2005a . Optical fibre reflectance sensor for the determination and speciation analysis of iron in fresh and seawater samples coupled to a multisyringe flow injection system . Anal. Chim. Acta 528 : 197 – 203 .
  • Pons , C. , R. Forteza , and V. Cerdà . 2005b . The use of anion-exchange disks in an optrode coupled to a multi-syringe flow-injection system for the determination and speciation analysis of iron in natural water samples . Talanta 66 : 210 – 217 .
  • Portela , J. G. , A. C. S. Costa , and L. S. G. Teixeira . 2004 . Determination of Vitamin B6 in pharmaceutical formulations by flow injection-solid phase spectrophotometry . J. Pharm. Biomed. Anal. 34 : 543 – 549 .
  • Reis , B. F. , F. R. P. Rocha , L. S. G. Teixeira , A. C. S. Costa , and M. Korn . 2000 . Construction of a flow cell for measurements by solid-phase spectrophotometry . Quim. Nova 23 : 116 – 118 .
  • Rocha , F. R. P. , and L. S. G. Teixeira . 2004 . Strategies to increase sensitivity in UV-VIS spectrophotometry . Quim. Nova 27 : 807 – 812 .
  • Rocha , F. R. P. , L. S. G. Teixeira , and J. A. Nóbrega . 2009 . Green strategies in trace analysis: A glimpse of simple alternatives for sample pretreatment and analyte determination . Spectrosc. Lett. 42 : 418 – 429 .
  • Ruedas-Rama , M. J. , M. López-Sanchez , A. Ruiz-Medina , A. Molina-Díaz , and M. J. Ayora-Cañada . 2005 . Flow-through sensor with Fourier transform Raman detection for determination of sulfonamides . Analyst 130 : 1617 – 1623 .
  • Ruedas-Rama , M. J. , A. Ruiz-Medina , and A. Molina-Díaz . 2003 . Bead injection spectroscopic flow-through renewable surface sensors with commercial flow cells as an alternative to reusable flow-through sensors . Anal. Chim. Acta 482 : 209 – 217 .
  • Ruiz-Medina , A. , M. L. Fernández de Córdova , M. J. Ayora-Cañada , M. I. Pascual-Reguera , and A. Molina-Díaz . 2000. A flow-through solid phase UV spectrophotometric biparameter sensor for the sequential determination of ascorbic acid and paracetamol. Anal. Chim. Acta 404: 131–139.
  • Ruiz-Medina , A. , M. L. Fernández de Córdova , and A. Molina-Díaz . 1999 . Flow injection-solid phase spectrofluorimetric determination of pyridoxine in presence of group B-vitamins . Fresenius J. Anal. Chem. 363 : 265 – 269 .
  • Ruiz-Medina , A. , M. L. Fernández de Córdova , and A. Molina-Díaz . 2001 . A flow-through optosensing device with fluorimetric transduction for rapid and sensitive determination of dipyridamole in pharmaceuticals and human plasma . Eur. J. Pharm. Sci. 13 : 385 – 391 .
  • Ruiz-Medina , A. , P. Ortega-Barrales , M. L. Fernández de Córdova , and A. Molina-Díaz . 2002 . Use of a continuous flow solid-phase spectroscopic sensor using two sensing zones: determination of thiamine and ascorbic acid . J. AOAC Intern. 85 : 369 – 374 .
  • Ruzicka , J. , and L. Scampavia . 1999 . From flow injection to bead injection . Anal. Chem. 71 : 257A – 263A .
  • Salinas-Castillo , A. , J. Fernandez-Sanchez , A. Segura-Carretero , and A. Fernandez-Gutierrez . 2004 . A facile flow-through phosphorimetric sensing device for simultaneous determination of naptalam and its metabolite 1-naphthylamine . Anal. Chim. Acta 522 : 19 – 24 .
  • Salinas-Castillo , A. , J. Fernandez-Sanchez , A. Segura-Carretero , and A. Fernandez-Gutierrez . 2005 . Solid-surface phosphorescence characterization of polycyclic aromatic hydrocarbons and selective determination of benzo(a)pyrene in water samples . Anal. Chim. Acta 550 : 53 – 60 .
  • Sanches-Pedreño , C. , J. A. Ortuño , M. I. Albero , M. S. Garcia , and J. C. G. de lãs Bayonas . 2000 . A new procedure for the construction of flow-through optodes. Application to determination of copper (II) . Fresenius J. Anal. Chem. 366 : 811 – 815 .
  • Skoog , D. A. , F. J. Holler , and D. M. West . 1994 . Analytical Chemistry: An Introduction . Philadelphia and London : Saunders College Pub .
  • Sotomayor , P. T. , I. M. Raimundo Jr ., G. Oliveira Neto , and W. A. Oliveira . 1998 . Evaluation of fibre optical chemical sensors for flow analysis systems . Sens. Actuators B 51 : 382 – 390 .
  • Teixeira , L. S. G. , A. C. S. Costa , J. C. R. Assis , S. L. C. Ferreira , and M. Korn . 2001 . Solid phase spectrophotometry for the determination of cobalt in pharmaceutical preparations . Mikrochim. Acta 137 : 29 – 33 .
  • Teixeira , L. S. G. , A. C. S. Costa , S. Garrigues , and M. de la Guardia . 2002 . Flow-injection solid phase partial least-squares spectrophotometric simultaneous determination of iron, nickel and zinc . J. Braz. Chem. Soc. 13 : 54 – 59 .
  • Teixeira , L. S. G. , and F. R. P. Rocha . 2007 . A green analytical procedure for sensitive and selective determination of iron in water samples by flow-injection solid-phase spectrophotometry . Talanta 71 : 1507 – 1511 .
  • Teixeira , L. S. G. , F. R. P. Rocha , M. Korn , B. F. Reis , S. L. C. Ferreira , and A. C. S. Costa . 1999 . Flow-injection solid-phase spectrophotometry for the determination of zinc in pharmaceutical preparations . Anal. Chim. Acta 383 : 309 – 315 .
  • Teixeira , L. S. G. , F. R. P. Rocha , M. Korn , B. F. Reis , S. L. C. Ferreira , and A. C. S. Costa . 2000 . Nickel and zinc determination by flow-injection solid-phase spectrophotometry exploiting different sorption rates . Talanta 51 : 1027 – 1033 .
  • Valero-Navarro , A. , P. Damiani , J. Fernandez-Sanchez , A. Segura-Carretero , and A. Fernandez-Gutierrez . 2009 . Chemometric-assisted MIP-optosensing system for the simultaneous determination of monoamine naphthalenes in drinking waters . Talanta 78 : 57 – 65 .
  • Valero-Navarro , A. , A. Salinas-Castillo , J. Fernandez-Sanchez , A. Segura-Carretero , R. Mallavia , and A. Fernandez-Gutierrez . 2009 . The development of a MIP-optosensor for the detection of monoamine naphthalenes in drinking water . Biosens. Bioelectron. 24 : 2305 – 2311 .
  • Xavier , M. P. , B. Vallejo , M. D. Marazuela , M. C. Moreno-Bondi , F. Baldini , and A. Falai . 2000. Fiber optic monitoring of carbamate pesticides using porous glass with covalently bound chloropheno red. Biosens. Bioelectron. 14: 895–905.
  • Xiong , Y. , H. Zhou , Z. Zhang , D. He , and C. He . 2006 . Determination of hydralazine with flow injection chemiluminescence sensor using molecularly imprinted polymer as recognition element . J. Pharm. Biomed. Anal. 41 : 694 – 700 .
  • Xiong , Y. , H. Zhou , Z. Zhang , D. He , and C. He . 2007 . Flow-injection chemiluminescence sensor for determination of isoniazid in urine sample based on molecularly imprinted polymer . Spectrochimica Acta Part A 66 : 341 – 346 .
  • Yoshimura , K. 1987 . Implementation of ion-exchanger absorptiometric detection in flow-analysis systems . Anal. Chem. 59 : 2922 – 2924 .
  • Yoshimura , K. 1988 . Application of ion-exchanger phase absorptiometry to flow analysis. Determination of trace amounts of chromium(V1) in water . Analyst 113 : 471 – 472 .
  • Yoshimura , K. , S. Matsuoka , and H. Waki . 1989 . Determination of molybdenum (VI) in natural water and rock by ion-exchange absorptiometry combined with flow analysis . Anal. Chim. Acta 225 : 313 – 321 .
  • Yoshimura , K. , H. Waki , and S. Ohashi . 1976 . Ion-exchanger colorimetry. 1. micro-determination of chromium, iron, copper and cobalt in water . Talanta 23 : 449 – 454 .
  • Zhang , Z. , S. Zhang , and X. Zhang , 2005 . Recent developments and applications of chemiluminescence sensors . Anal. Chim. Acta 541 : 37 – 47 .
  • Zhou , H. , Z. Zhang , D. He , and Y. Xiong . 2005 . Flow through chemiluminescence sensor using molecularly imprinted polymer as recognition elements for detection of salbutamol . Sens. Actuators, B 107 : 798 – 804 .
  • Zhu , H. L. , H. W. Chen , and Y. L. Zhou . 2003 . Determination of thiamine in pharmaceutical preparations by sequential injection renewable surface solid-phase spectrofluorometry . Anal. Sci. 19 : 289 – 294 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.