REFERENCES
- Aldous , K. M. , R. M. Dagnall , and T. S. West . 1970 . The flame-spectroscopic determination of sulphur and phosphorus in organic and aqueous matrices by using a simple filter photometer . Analyst 95 : 417 – 424 .
- Brinkman , U. A. T. , R. B. Geerdink , and A. D. Kok . 1984 . Normal- and reversed-phase liquid chromatography with on-line electron-capture detection . J. Chromatogr. A. 291 : 195 – 201 .
- Fujii , T. 1996a . Surface ionization organic mass spectrometry: Applications in gas chromatography . Eur. Mass Spectrom. 2 : 263 – 271 .
- Fujii , T. 1996b . Surface ionization organic mass spectrometry: Mechanism . Eur. Mass Spectrom. 2 : 91 – 114 .
- Fujii , T. , and H. Arimoto . 1985 . New sensitive and selective detector for gas chromatography: Surface ionization detector with a hot platinum emitter . Anal. Chem. 57 : 2625 – 2628 .
- Fujii , T. , and H. Arimoto . 1993 . Surface ionization detector . In Detectors for Capillary Chromatography , eds. H. H. Hill and D. G. McMinn . New York : Wiley Interscience , pp. 169 – 191 .
- Fujii , T. , H. Jimba , and H. Arimoto . 1990 . Mass spectrometric studies on the response mechanism of surface ionization detectors for gas chromatography . Anal. Chem. 62 : 107 – 111 .
- Karnicky , J. F. , L. T. Zitelli , and S. Van der Wal . 1987 . Ultrasonic micronebulizer inferface for high-performance liquid chromatography with flame photometric detector . Anal. Chem. 59 : 327 – 333 .
- Kientz , C. E. , A. Verweij , G. de Jong , and U. A. T. Brinkman . 1992. Flame-based thermionic detection coupled on-line with microcolumn liquid chromatography: I. Optimization of the system. J. Chromatogr. 626: 59–69.
- Krejci , M. , K. Tesarik , and M. Pajurek . 1981 . Flow characteristics and technology of capillary columns with inner diameters less than 15 µm in liquid chromatography . J. Chromatogr. A. 218 : 167 – 178 .
- Lacourse , W. R. , and C. O. Dasenbrock . 1998 . Assay for cephapirin and ampicillin in raw milk by high-performance liquid chromatography–integrated pulsed amperometric detection . Anal. Chem. 70 : 37 – 52 .
- Maris , F. A. , R. J. Van Delft , R. W. Frei , R. B. Geerdink , and U. A. T. Brinkman . 1986 . On-line thermionic detection for narrow-bore reversed-phase liquid chromatography . Anal. Chem. 58 : 1634 – 1638 .
- McGuffin , V. L. , and M. Novotny . 1981 . Flame emission detection in microcolumn liquid chromatography . Anal. Chem. 53 : 946 – 951 .
- McGuffin , V. L. , and M. Novotny . 1983 . Thermionic detection in microcolumn liquid chromatography . Anal. Chem. 55 : 2296 – 2302 .
- Neverova , I. , and J. E. Van Eyk . 2005 . Role of chromatographic techniques in proteomic analysis . J. Chromatogr. B. 815 : 51 – 63 .
- Sherma , J. 1995 . Pesticides . Anal. Chem. 67 : 1R – 20R .
- Tinke , A. P. , R. A. M. van der Hoeven , W. M. A. Niessen , U. R. Tjaden , and J. van der Greef . 1993 . Electrospray mass spectrometry of neutral and acidic oligosaccharides: Methylated cyclodextrins and identification of unknowns derived from fruit material . J. Chromatogr. 647 : 63 – 72 .