158
Views
2
CrossRef citations to date
0
Altmetric
FLOW INJECTION ANALYSIS

Flow Injection Determination of Lactate Using Immobilized Lactate Dehydrogenase Enzyme with Tris(2,2′-Bipyridyl)Ruthenium(III) Chemiluminescence Detection

, , , &
Pages 654-664 | Received 28 Oct 2014, Accepted 01 Feb 2015, Published online: 22 Feb 2016

References

  • Avramescu, A., T. Noguer, M. Avramescu, and J.-L. Marty. 2002. Screen-printed biosensors for the control of wine quality based on lactate and acetaldehyde determination. Analytica Chimica Acta 458: 203–13. doi:10.1016/s0003-2670(01)01580-x
  • Ballesta-Claver, J., M. C. Valencia-Mirón, and L. F. Capitán-Vallvey. 2008. One-shot lactate chemiluminescent biosensor. Analytica Chimica Acta 629: 136–44. doi:10.1016/j.aca.2008.09.028
  • Beneke, R., R. M. Leithauser, and O. Ochentel. 2011. Blood lactate diagnostics in exercise testing and training. International Journal of Sports Physiology and Performance 6: 8–24.
  • Biagi, S., S. Ghimenti, M. Onor, and E. Bramanti. 2012. Simultaneous determination of lactate and pyruvate in human sweat using reversed-phase high-performance liquid chromatography: A noninvasive approach. Biomedical Chromatography 26: 1408–15. doi:10.1002/bmc.2713
  • Boehringer Mannheim, 1989. Enzymatic Bio-Analysis, Catalog No. 1112821.
  • Brandt, R. B., S. A. Siegel, M. G. Waters, and M. H. Bloch. 1980. Spectrophotometric assay for d-(−)-lactate in plasma. Analytical Biochemistry 102: 39–46. doi:10.1016/0003-2697(80)90314-0
  • Cayman Chemical Company. 2012. L-Lactate Assay Kit, item No. 700510, Ann Arbor, MI, USA.
  • Cevasco, G., A. M. Piatek, C. Scapolla, and S. Thea. 2011. A simple, sensitive and efficient assay for the determination of D- and L-lactic acid enantiomers in human plasma by high-performance liquid chromatography. Journal of Chromatography A 1218: 787–92. doi:10.1016/j.chroma.2010.12.041
  • De Baere S., V. Eeckhaut, M. Steppe, C. De Maesschalck, P. De Backer, F. Van Immerseel, and S. Croubels. 2013. Development of a HPLC–UV method for the quantitative determination of four short-chain fatty acids and lactic acid produced by intestinal bacteria during in vitro fermentation. Journal of Pharmaceutical and Biomedical Analysis 80: 107–15. doi:10.1016/j.jpba.2013.02.032
  • Dremel, B. A. A., W. Yang, and R. D. Schmid. 1990. On-line determination of lactic acid during kefir fermentation based on a fibre-optic lactic acid biosensor and flow-injection analysis. Analytica Chimica Acta 234: 107–12. doi:10.1016/s0003-2670(00)83544-8
  • Franco, E. J., H. Hofstetter, and O. Hofstetter. 2009. Determination of lactic acid enantiomers in human urine by high-performance immunoaffinity LC–MS. Journal of Pharmaceutical and Biomedical Analysis 49: 1088–91. doi:10.1016/j.jpba.2009.01.033
  • Gerardi, R. D., N. W. Barnett, and P. Jones. 1999. Two chemical approaches for the production of stable solutions of tris(2,2′-bipyridyl)ruthenium(III) for analytical chemiluminescence. Analytica Chimica Acta 388: 1–10. doi:10.1016/s0003-2670(99)00042-2
  • Gollnick, P. D., W. M. Bayly, and D. R. Hodgson. 1986. Exercise intensity, training, diet, and lactate concentration in muscle and blood. Medicine & Science in Sports & Exercise 18: 334–40. doi:10.1249/00005768-198606000-00015
  • Gomes, S. P., M. Odlozilıkov, M. G. Almeida, A. N. Araujo, C. M. C. M. Couto, M. Conceicao, and B. S. M. Montenegro. 2007. Application of lactate amperometric sol–gel biosensor to sequential injection determination of L-lactate. Journal of Pharmaceutical and Biomedical Analysis 43: 1376–81. doi:10.1016/j.jpba.2006.11.027
  • Haghighi, B., and S. Bozorgzadeh. 2011. Fabrication of a highly sensitive electrochemiluminescence lactate biosensor using ZnO nanoparticles decorated multiwalled carbon nanotubes. Talanta 85: 2189–93. doi:10.1016/j.talanta.2011.07.071
  • Hemmi, A., K. Yagiuda, N. Funazaki, S. Ito, Y. Asano, T. Imato, K. Hayashi, and I. Karube. 1995. Development of a chemiluminescence detector with photodiode detection for flow-injection analysis and its application to L-lactate analysis. Analytica Chimica Acta 316: 323–27. doi:10.1016/0003-2670(95)00371-6
  • Holzmann, M., S. Cnattingius, and L. Nordström. 2012. Lactate production as a response to intrapartum hypoxia in the growth-restricted fetus. BJOG: An International Journal of Obstetrics & Gynaecology 119: 1265–69. doi:10.1111/j.1471-0528.2012.03432.x
  • Huck, H., A. Schelter-Graf, and H.-L. Schmidt. 1984. Measurement and calculation of the calibration graphs for flow injection analysis using enzyme reactors with immobilized dehydrogenases and an amperometric NADH detector. Bioelectrochemistry and Bioenergetics 13: 199–209. doi:10.1016/0302-4598(84)85127-2
  • Jameison, F., R. I. Sanchez, L. Dong, J. K. Leland, D. Yost, and M. T. Martin. 1996. Electrochemiluminescence-based quantitation of classical clinical chemistry analytes. Analytical Chemistry 68: 1298–302. doi:10.1021/ac950990k
  • Koppenol, W. H., P. L. Bounds, and C. V. Dang. 2011. Otto Warburg’s contributions to current concepts of cancer metabolism. Nature Reviews Cancer 11: 325–37. doi:10.1038/nrc3038
  • Kost, G. J., T. H. Nguyen, and Z. Tang. 2000. Whole-blood glucose and lactate. Trilayer biosensors, drug interference, metabolism, and practice guidelines. Archives of Pathology & Laboratory Medicine 124: 1128–34.
  • Li, Y. S., and X. F. Gao. 2002. Flow injection analysis and application for chemistry analysis. Changchun, China: The Jilin People’s Publisher. ISBN 7–206-02728–8/R·37.
  • Lima, J. L. F. C., T. I. M. S. Lopes, and A. O. S. S. Rangel. 1998. Enzymatic determination of L(+) lactic and L(−) malic acids in wines by flow-injection spectrophotometry. Analytica Chimica Acta 366: 187–91. doi:10.1016/s0003-2670(98)00106-8
  • Lowry, O. H., N. J. Rosebrough, A. L. Farr, and R. J. Randall. 1951. Protein measurement with the Folin phenol reagent. The Journal of Biological Chemistry 193: 265–75.
  • Marquette, C. A., and L. J. Blum. 1999. Luminol electrochemiluminescence-based fibre optic biosensors for flow injection analysis of glucose and lactate in natural samples. Analytica Chimica Acta 381: 1–10. doi:10.1016/s0003-2670(98)00703-x
  • Martelli, P. B., B. F. Reis, A. N. Araujo, M. Conceicao, and B. S. M. Montenegro. 2001. A flow system with a conventional spectrophotometer for the chemiluminescent determination of lactic acid in yoghurt. Talanta 54: 879–85. doi:10.1016/s0039-9140(01)00360-5
  • Martin, A. F., and T. A. Nieman. 1997. Chemiluminescence biosensors using tris(2,2′bipyridyl)ruthenium(II) and dehydrogenases immobilized in cation exchange polymers. Biosensors and Bioelectronics 12: 479–89. doi:10.1016/s0956-5663(97)00004-3
  • Masoom, M., R. Robert, and L. Binaglia. 1990. Determination of phosphatidylcholine in a flow injection system using immobilized enzyme reactors. Analytical Biochemistry 187(1990): 240–45. doi:10.1016/0003-2697(90)90450-n
  • McGee, D., T. C. Jessee, M. H. Stone, and D. Blessing. 1992. Leg and hip endurance adaptations to three weight-training programs. The Journal of Strength and Conditioning Research 6: 92–95. doi:10.1519/00124278-199205000-00005
  • Palleschi, G., M. Mascini, L. Bernardi, and P. Zeppilli. 1990. Lactate and glucose electrochemical biosensors for the evaluation of the aerobic and anaerobic threshold in runners. Medical & Biological Engineering & Computing 28: B25–28. doi:10.1007/bf02442677
  • Pellegrini, D., M. Onor, I. Degano, and E. Bramanti. 2014. Development and validation of a novel derivatization method for the determination of lactate in urine and saliva by liquid chromatography with UV and fluorescence detection. Talanta 130: 280–87. doi:10.1016/j.talanta.2014.07.015
  • Pfeiffer, D., B. Mollor, N. Klimes, J. Szeponik, and S. Fischer. 1997. Amperometric lactate oxidase catheter for real-time lactate monitoring based on thin film technology. Biosensors and Bioelectronics 12: 539–50. doi:10.1016/s0956-5663(97)00014-6
  • Pilloton, R., T. N. Nwosu, and M. Mascini. 1988. Amperometric determination of lactic acid. Applications on milk samples. Analytical Letters 21: 727–40. doi:10.1080/00032718808070855
  • Rishi, L., M. Yaqoob, A. Nabi, and M. Masoom. 2005. Chromatographic removal of product in-line with immobilized enzyme bioreactor for the synthesis of NADH. Journal of the Chemical Society of Pakistan 27: 59–64.
  • Ruzicka, J., and H. Hansen. 1988. Flow injection analysis, 2nd ed. New York, lst: Wiley.
  • Shah, N. C., O. Lyandres, J. T. Walsh, Jr., M. R. Glucksberg, and R. P. Van Duyne. 2007. Lactate and sequential lactate−glucose sensing using surface-enhanced Raman spectroscopy. Analytical Chemistry 79: 6927–32. doi:10.1021/ac0704107
  • Shimomura, T., T. Sumiya, M. Ono, T. Ito, and T. Hanaoka. 2012. Amperometric L-lactate biosensor based on screen-printed carbon electrode containing cobalt phthalocyanine, coated with lactate oxidase-mesoporous silica conjugate layer. Analytica Chimica Acta 714: 114–20. doi:10.1016/j.aca.2011.11.053
  • Teunissen, M. J., S. A. E. Marras, H. J. M. Op den Camp, and G. D. Vogels. 1989. Improved method for simultaneous determination of alcohols, volatile fatty acids, lactic acid or 2,3 butanediol in biological samples. Journal of Microbiological Methods 10: 247–54. doi:10.1016/0167-7012(89)90012-2
  • Tsukatani, T., and K. Matsumoto. 2006. Flow-injection fluorometric quantification of pyruvate using co-immobilized pyruvate decarboxylase and aldehyde dehydrogenase reactor: Application to measurement of acetate, citrate and l-lactate. Talanta 69: 637–42. doi:10.1016/j.talanta.2005.10.034
  • Tumang, C. A., E. P. Borges, and B. F. Reis. 2001. Multicommutation flow system for spectrophotometric L(+)lactate determination in silage material using an enzymatic reaction. Analytica Chimica Acta 438: 59–65. doi:10.1016/s0003-2670(01)00827-3
  • Volpe, G., D. Moscone, D. Compagnone, and G. Palleachi. 1995. In vivo continuous monitoring of L-lactate coupling subcutaneous microdialysis and an electrochemical biocell. Sensors and Actuators B: Chemical 24: 138–42. doi:10.1016/0925-4005(95)85029-5
  • Wang, J., M. P. Chatrathi, and G. E. Collins. 2007. Simultaneous microchip enzymatic measurements of blood lactate and glucose. Analytica Chimica Acta 585: 11–16. doi:10.1016/j.aca.2006.12.001
  • Wang, X., N. Ishii, M. Ye, M. Munkhjargal, K. Miyajima, T. Arakawa, H. Saito, H. Kudo, H. Endo, and K. Mitsubayashi. 2013. Application of chemiluminescence involving flow injection analysis to determination of glucose, glutamic acid and lactic acid for food analysis. IEEE Sensors 1–4. doi:10.1109/icsens.2013.6688378. 2013 – Proceedings 6688378.
  • Yao, T., and T. Yano. 2004. On-line microdialysis assay of l-lactate and pyruvate in vitro and in vivo by a flow-injection system with a dual enzyme electrode. Talanta 63: 771–75. doi:10.1016/j.talanta.2003.11.033

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.