References
- Anselmia, A., P. Tittarelli, and D. A. Katskov. 2002. Determination of trace elements in automotive fuels by filter furnace atomic absorption spectrometry. Spectrochimica Acta Part B: Atomic Spectroscopy 57:403–11. doi:10.1016/S0584-8547(01)00392-5.
- Apostoli, P. 1992. Criteria for the definition of reference values for toxic metals. Science of the Total Environment 120:23–37. doi:10.1016/0048-9697(92)90214-D.
- Bianchi, S. R., Amaral, C. D. B., Silva, C. S., and Nogueira, A. R. A. 2017. Determination of selenium in bovine semen by ICP-MS using formic acid for sample preparation. Journal of the Brazilian Chemical Society 28:2357–64. doi:10.21577/0103-5053.20170089.
- Byrne, J. P., Chakrabarti, C. L., Gregoire, D. C., Lamoureux, M., and Ly, T. 1992. Mechanisms of chloride interferences in atomic-absorption spectrometry using a graphite-furnace atomizer investigated by electrothermal vaporization inductively coupled plasma mass-spectrometry. 1. Effect of magnesium-chloride matrix and ascorbic-acid chemical modifier on manganese. Journal of Analytical Atomic Spectrometry 7:371–81. doi:10.1039/Ja9920700371.
- Bulska, E., and K. Pyrzyńska. 1997. Comparison of chemical modifiers for the determination of selenium by electrothermal atomic-absorption spectrometry. Spectrochimica Acta Part B: Atomic Spectroscopy 52:1283–91. doi:10.1016/S0584-8547(97)00050-5.
- Canário, C., P. Ngobeni, D. A. Katskov, and Y. Thomassen. 2004. Transverse heated filter atomizer: Atomic absorption spectrometric determination of Pb and Cd in whole blood. Journal of Analytical Atomic Spectrometry 19:1468–73. doi:10.1039/B409022E.
- Christensen, J. M. 1995. Human exposure to toxic metals: Factors influencing interpretation of biomonitoring results. Science of The Total Environment 166:89–135. doi:10.1016/0048-9697(95)04478-J.
- Damin, I. C. F., M. B. Dessuy, T. S. Castilhos, M. M. Silva, M. G. R. Vale, B. Welz, and D. A. Katskov. 2009. Comparison of direct sampling and emulsion analysis using a filter furnace for the determination of lead in crude oil by graphite furnace atomic absorption spectrometry. Spectrochimica Acta Part B: Atomic Spectroscopy 64:530–36. doi:10.1016/j.sab.2009.03.002.
- Dessuy, M. B., M. G. R. Vale, A. S. Souza, S. L. C. Ferreira, B. Welz, and D. A. Katskov. 2008. Method development for the determination of lead in wine using electrothermal atomic absorption spectrometry comparing platform and filter furnace atomizers and different chemical modifiers. Talanta 74:1321–29. doi:10.1016/j.talanta.2007.08.048.
- Dědina, J., and D. L. Tsalev. 1995. Hydride generation atomic absorption spectrometry, 544. Baffins Lane, Chichester, West Sussex, England: Wiley.
- Grinshtein, I. L., Y. A. Vilpan, A. V. Saraev, and L. A. Vasilieva. 2001. Direct atomic absorption determination of cadmium and lead in strongly interfering matrices by double vaporization with a two-step electrothermal atomizer. Spectrochimica Acta Part B: Atomic Spectroscopy 56:261–74. doi:10.1016/S0584-8547(00)00306-2.
- Gucer, S., and H. Massmann. 1983. Untergrundstörungen durch organische Lösungsmittel in der Atomabsorptionsspektrometrie mit Graphitöfen. Spectrochimica Acta Part B: Atomic Spectroscopy 38:573–80. doi:10.1016/0584-8547(83)80033-0.
- Iyengar, V., and J. Woittiez. 1988. Trace elements in human clinical specimens: Evaluation of literature date to identify reference values. Clinical Chemistry 34:474–81.
- Izgi, B., S. Gucer, and R. Jaćimović. 2006. Determination of selenium in garlic (Allium sativum) and onion (Allium cepa) by electro thermal atomic absorption spectrometry. Food Chemistry 99:630–37. doi:10.1016/j.foodchem.2005.08.033.
- Kristiansen, J., J. M. Christensen, B. S. Iversen, and E. Sabbioni. 1997. Toxic trace element reference levels in blood and urine: Influence of gender and lifestyle factors. Science of the Total Environment 204:147–60. doi:10.1016/S0048-9697(97)00155-1.
- Lyon, T. D. B, G. S. Fell, R. C. Hutton, and A. N. Eaton. 1988. Evaluation of inductively coupled argon plasma mass spectrometry (ICP-MS) for simultaneous multi-element trace analysis in clinical chemistry. Journal of Analytical Atomic Spectrometry 3:265–71. doi:10.1039/JA9880300265.
- Ngobeni, P., C. Canário, D. A. Katskov, and Y. Thomassen. 2003. Transverse heated filter atomizer: atomic absorption determination of Pb and Cd in urine. Journal of Analytical Atomic Spectrometry 18:762–68. doi:10.1039/B301170D.
- Rayman, M. 2017. Selenium intake and status in health & disease. Free Radical Biology and Medicine 112:5–5, Supplement: 1, Meeting Abstract: P6. doi:10.1016/j.freeradbiomed.2017.10.353.
- Styris, D. L., L. J. Prell, D. A. Redfield, J. A. Holcombe, D. A. Bass, and V. Majidi. 1991. Mechanisms of selenium vaporization with palladium modifiers using electrothermal atomization and mass spectrometric detection. Analytical Chemistry 63:508–17. doi:10.1021/ac00005a024.
- Volynsky, A. B. 2000. Mechanisms of action of platinum group modifiers in electrothermal atomic absorption spectrometry. Spectrochimica Acta Part B: Atomic Spectroscopy 55 (2):103–50. doi:10.1016/S0584-8547(99)00175-5.
- Walker, A. W. 1992. The trace element analysis. Guildford: Royal Surrey Country and St. Luke’s Hospital.