32
Views
16
CrossRef citations to date
0
Altmetric
Original Articles

Load frequency self-tuning regulator for interconnected power systems with unknown deterministic load disturbances

&
Pages 1555-1568 | Received 17 Feb 1988, Published online: 01 Apr 2008

References

  • Bohn , E. V. and Miniesy , S. M. 1972 . Optimum load-frequency sampled-data control with randomly varying system disturbances. I.E.E.E . Transactions on Power Apparatus and Systems , 91 : 1916 – 1922 .
  • Cheng , S. J. , Malik , O. P. and Hope , G. S. 1986 . Self-tuning stabiliser for a multimachine power system . Proceedings of the Institution of Electrical Engineers , 133 : 176 – 185 .
  • Clarke , D. W. , Phil , D. and James , R. H. 1971 . Design of digital controllers for randomly disturbed systems . Proceedings of the Institution of Electrical Engineers , 118 : 1503 – 1506 .
  • Elgerd , O. I. 1983 . Electric Energy System Theory: an Introduction , New York : McGraw-Hill .
  • Elgerd , O. I. and Fosha , C. E. 1970 . Optimum megawatt-frequency control of multiarea electric energy systems. I.E.E.E . Transactions on Power Apparatus and Systems , 89 : 556 – 562 .
  • Fosha , C. E. and Elgerd , O. I. 1970 . The megawatt-frequency control problem: a new approach via optimal control theory. I.E.E.E . Transactions on Power Apparatus and Systems , 89 : 563 – 577 .
  • Glover , J. D. and Schweppe , P. C. 1972 . Advanced load frequency control. I.E.E.E . Transactions on Power Apparatus and Systems , 91 : 2095 – 2103 .
  • Hsu , Y. Y. and Chan , W. C. 1984 . Optimal variable structure controller for the load-frequency control of interconnected hydrothermal power systems . International Journal of Elec- trical Power and Energy Systems , 6 : 221 – 229 .
  • Kanniah , J. , Tripathy , S. C. , Malik , O. P. and Hope , G. S. 1984 . Microprocessor-based adaptive load-frequency control . Proceedings of the Institution of Electrical Engineers , 131 : 121 – 128 .
  • Kothari , M. L. , Satsangi , P. S. and Nanda , J. 1981 . Sampled-data automatic generation control of interconnected reheat thermal systems considering generation rate con- straints. I.E.E.E . Transactions on Power Apparatus and Systems , 100 : 2334 – 2342 .
  • Landau , I. D. and Tomizuka , M. 1981 . Theory and Practice of Adaptive Control Systems , Tokyo : Ohmu sha .
  • Nanda , J. and Kaul , B. L. 1978 . Automatic generation control of an interconnected power system . Proceedings of the Institution of Electrical Engineers , 125 : 385 – 390 .
  • Sheirah , M. A. and Fattah , M. M. 1984 . Improved load-frequency self-tuning regulator . International Journal of Control , 39 : 143 – 158 .
  • Tripathy , S. C. , Bhatti , T. S. , Jha , C. S. , Malik , O. P. and Hope , G. S. 1984 . Sampled data automatic generation control analysis with reheat steam turbines and governor dead- band effects. I.E.E.E . Transactions on Power Apparatus and Systems , 103 : 1045 – 1051 .
  • Yamashita , K. and Taniguchi , T. 1986 . Optimal observer design for load-frequency control . International Journal of Electrical Power and Energy Systems , 8 : 93 – 100 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.