256
Views
3
CrossRef citations to date
0
Altmetric
Technical Material

Dosimetric effect of carbon fiber treatment couch in boron neutron capture therapy

, , , , &
Pages 541-548 | Received 15 Apr 2023, Accepted 25 Jun 2023, Published online: 17 Jul 2023

References

  • González SJ, Carando DG, Cruz GAS, et al. Voxel model in BNCT treatment planning: performance analysis and improvements. Phys Med Biol. 2005;50(3):441–458. doi: 10.1088/0031-9155/50/3/004
  • Li HS, Liu Y-W, Lee CY, et al. Verification of the accuracy of BNCT treatment planning system THORplan. Appl Radiat Isot. 2009;67(7–8):S122–S125. doi: 10.1016/j.apradiso.2009.03.029
  • Kumada H, Matsumura A, Sakurai H, et al. Project for the development of the linac based NCT facility in University of Tsukuba. Appl Radiat Isot. 2014;88:211–215. DOI:10.1016/j.apradiso.2014.02.018
  • Kumada H, Takada K, Aihara T, et al. Verification for dose estimation performance of a Monte-Carlo based treatment planning system in University of Tsukuba. Appl Radiat Isot. 2020;166:109222. DOI:10.1016/j.apradiso.2020.109222
  • Hu N, Tanaka H, Kakino R, et al. Evaluation of a treatment planning system developed for clinical boron neutron capture therapy and validation against an independent Monte Carlo dose calculation system. Radiat Oncol. 2021;16(1):243. doi: 10.1186/s13014-021-01968-2
  • Fraass B, Doppke K, Hunt M, et al. American association of physicists in medicine radiation therapy committee task group 53: quality assurance for clinical radiotherapy treatment planning. Med Phys. 1998;25(10):1773–1829. doi: 10.1118/1.598373
  • Olch AJ, Gerig L, Li H, et al. Dosimetric effects caused by couch tops and immobilization devices: report of AAPM task group 176. Med Phys. 2014;41(6Part1):061501. doi: 10.1118/1.4876299
  • Sheykhoo A, Abdollahi S, Hadizadeh Yazdi MH, et al. Effects of Siemens TT-D carbon fiber table top on beam attenuation, and build up region of 6 MV photon beam. Rep Pract Oncol Radiother. 2017;22(1):19–28. doi: 10.1016/j.rpor.2016.09.001
  • Tuğrul T. Absorption ratio of treatment couch and effect on surface and build-up region doses. Rep Pract Oncol Radiother. 2018;23(1):1–5. doi: 10.1016/j.rpor.2017.10.004
  • Sauerwein W, Wittig A, Moss R, et al. editors. Neutron capture therapy: principles and applications. Berlin, Heidelberg: Springer Berlin Heidelberg; 2012. 10.1007/978-3-642-31334-9
  • Zhang K, Xuemin W, Fang L, et al. Evaluation of Elekta carbon fiber treatment couch model. mod. oncol. 2021;29(10):1780–1784. doi:10.3969/j.issn.1672-4992.2021.10.029
  • Wang YQ, Du JL, Lin H, et al. An AB-BNCT epithermal neutron source using 7Li(p,n)7Be reaction. J Inst. 2023;18(3):03006. doi: 10.1088/1748-0221/18/03/P03006
  • Paganetti H, Jiang H, Parodi K, et al. Clinical implementation of full Monte Carlo dose calculation in proton beam therapy. Phys Med Biol. 2008;53(17):4825–4853. doi: 10.1088/0031-9155/53/17/023
  • Schneider W, Bortfeld T, Schlegel W. Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions. Phys Med Biol. 2000;45(2):459–478. doi: 10.1088/0031-9155/45/2/314
  • Sato T, Hashimoto S, Inaniwa T, et al. Implementation of simplified stochastic microdosimetric kinetic models into PHITS for application to radiation treatment planning. Int J Radiat Biol. 2021;97(10):1450–1460. doi: 10.1080/09553002.2021.1956003
  • Hu N, Tanaka H, Kakino R, et al. Improvement in the neutron beam collimation for application in boron neutron capture therapy of the head and neck region. Sci Rep. 2022;12(1):13778. doi: 10.1038/s41598-022-17974-7
  • Iwamoto O, Iwamoto N, Kunieda S, et al. Japanese evaluated nuclear data library version 5: JENDL-5. J Nucl Sci Technol. 2023;60(1):1–60. doi: 10.1080/00223131.2022.2141903
  • Kimura A, Nakamura S, Endo S, et al. Detector light response modeling for a thick continuous slab detector. J Nucl Sci Technol. 2008;45(7):634–638. doi: 10.1080/00223131.2022.2134224
  • Tian F, Zhao S, Geng C, et al. Use of a neural network-based prediction method to calculate the therapeutic dose in boron neutron capture therapy of patients with glioblastoma. Med Phys. 2023;50(5):3008–3018. [Internet]. [cited 2023 Mar 16];n/a.Available from: https://onlinelibrary.wiley.com/doi/abs/10.1002/mp.16215
  • Chetty IJ, Curran B, Cygler JE, et al. Report of the AAPM task group no. 105: issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning: AAPM task group report no. 105: Monte Carlo-based treatment planning. Med Phys. 2007;34(12):4818–4853.
  • Keall PJ, Siebers JV, Jeraj R, et al. The effect of dose calculation uncertainty on the evaluation of radiotherapy plans. Med Phys. 2000;27(3):478–484. doi: 10.1118/1.598916
  • Miften M, Olch A, Mihailidis D, et al. Tolerance limits and methodologies for IMRT measurement-based verification QA: recommendations of AAPM task group no. 218. Med Phys. 2018;45(4):e53–e83. doi: 10.1002/mp.12810
  • Yu H-T, Liu Y-W, Lin T-Y, et al. BNCT treatment planning of recurrent head-and-neck cancer using THORplan. Appl Radiat Isot. 2011;69(12):1907–1910. doi: 10.1016/j.apradiso.2011.02.041

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.