References
- “Information Portal for the Fukushima Daiichi Accident Analysis and Decommissioning Activities”; https://fdada.info/en/home2/ (current as of Dec. 9, 2019).
- G. KATATA et al., “Detailed Source Term Estimation of the Atmospheric Release for the Fukushima Daiichi Nuclear Power Station Accident by Coupling Simulations of an Atmospheric Dispersion Model with an Improved Deposition Scheme and Oceanic Dispersion Model,” Atmos. Chem. Phys., 15, 1029 (2015); https://doi.org/10.5194/acp-15-1029-2015.
- M. SOGALLA et al., “What the ‘Peaks’ in Local Dose Rate Measured During the Fukushima Accident Tell About Deposition,” Eurosafe, Air Concentration and Release of Radioactivity (2016); https://www.eurosafeforum.org/sites/default/files/Eurosafe2016/Seminar4/4.02_Sogalla_Eurosafe%202016_Seminar%20RP_161104.pdf (current as of Dec. 9, 2019).
- M. PELLEGRINI et al., “Confirmation of Severe Accident Code Modeling in Light of the Findings at Fukushima Daiichi NPPs,” Nucl. Eng. Des., 354, 110217 (Dec. 1, 2019); https://doi.org/10.1016/j.nucengdes.2019.110217.
- L. E. HERRANZ et al., “Overview and Outcomes of the OECD/NEA Benchmark Study of the Accident at the Fukushima Daiichi NPS (BSAF)—Results of Severe Accident Analyses for Unit 1,” presented at NURETH-18, Portland, Oregon, August 18–22, 2019.
- M. SONNENKALB et al., “Overview and Outcomes of the OECD/NEA Benchmark Study of the Accident at the Fukushima Daiichi NPS (BSAF)—Results of Severe Accident Analyses for Unit 2,” presented at NURETH-18, Portland, Oregon, August 18–22, 2019.
- T. LIND et al., “Overview and Outcomes of the OECD/NEA Benchmark Study of the Accident at the Fukushima Daiichi NPS (BSAF)—Results of Severe Accident Analyses for Unit 3,” presented at NURETH-18, Portland, Oregon, August 18–22, 2019.
- M. PELLEGRINI et al., “Benchmark Study of the Accident at the Fukushima Daiichi Nuclear Power Plant (BSAF Project) Phase I Summary Report”; http://www.oecd-nea.org/nsd/docs/2015/csni-r2015-18.pdf (current as of Dec. 9, 2019).
- “Evaluation of the Situation of Cores and Containment Vessels of Fukushima Daiichi Nuclear Power Station Units 1 to 3 and Examination into Unsolved Issues in the Accident Progression,” Progress Report No. 5, Attachment 3-5, “The Cause of RCIC Shutdown in Unit 3,” Tokyo Electric Power Company, Inc.; http://www.tepco.co.jp/en/press/corp-com/release/betu14_e/images/140806e0124.pdf (current as of Dec. 25, 2017).
- “Evaluation of the Situation of Cores and Containment Vessels of Fukushima Daiichi Nuclear Power Station Units 1 to 3 and Examination into Unsolved Issues in the Accident Progression,” Progress Report No. 5, Attachment 3-10, “Evaluation of the Fraction of Unit-3 Vent Gas that Flowed into Unit-4 Reactor Building,” Tokyo Electric Power Company, Inc.; https://www4.tepco.co.jp/en/press/corp-com/release/betu17_e/images/171225e0242.pdf (current as of Dec. 25, 2017).