References
- Jellum E., Andersen A., Lund‐Larsen P., Theodorsen L., Orjasaeter H. The JANUS serum bank. Sci Total Environ 1993; 139–40: 527–35
- Gislefoss R., Jellum E. The Janus serum bank and biomarkers of cancer. Norw J Epidemiol 2006; 16: 53–7
- Jellum E., Andersen A., Lund‐Larsen P., Theodorsen L., Orjasaeter H. Experiences of the Janus Serum Bank in Norway. Environ Health Perspect 1995; 103(Suppl 3)85–8
- Boyanton B. L., Jr., Blick K. E. Stability studies of twenty‐four analytes in human plasma and serum. Clin Chem 2002; 48: 2242–7
- Donnelly J. G., Soldin S. J., Nealon D. A., Hicks J. M. Stability of twenty‐five analytes in human serum at 22 degrees C, 4 degrees C, and −20 degrees C. Pediatr Pathol Lab Med 1995; 15: 869–74
- Heins M., Heil W., Withold W. Storage of serum or whole blood samples? Effects of time and temperature on 22 serum analytes. Eur J Clin Chem Clin Biochem 1995; 33: 231–8
- Wilson S. S., Guillan R. A., Hocker E. V. Studies of the stability of 18 chemical constituents of human serum. Clin Chem 1972; 18: 1498–503
- Solberg H. E. Establishment and use of reference values. Tietz Textbook of Clinical Chemistry and Molecular diagnostics, C. A Burtis, E. R Ashwood, D. E Bruns. Elsevier Saunders, St. Louis, Miss. 2006; 437
- Kenny D., Solberg H. E. RefVal for windows – migrating to the Windows environment with the help of Visual Basic. Clin Chim Acta 1993; 222: 19–21
- Zhou Q., Li S., Li X., Wang W., Wang Z. Detection of outliers and establishment of targets in external quality assessment programs. Clin Chim Acta 2006; 372: 94–7
- Ricos C., Alvarez V., Cava F., Garcia‐Lario J. V., Hernandez A., Jimenez C. V., et al. Current databases on biological variation: pros, cons and progress. Scand J Clin Lab Invest 1999; 59: 491–500
- Sonntag O. Haemolysis as an interference factor in clinical chemistry. J Clin Chem Clin Biochem 1986; 24: 127–39
- Urdal P., Bolann B., Marstein S., Rustad P., Steensland H., Asberg A. [Updated reference intervals for clinical chemical components]. Tidsskr Nor Laegeforen 2004; 124: 1515–17
- Ono T., Kitaguchi K., Takehara M., Shiiba M., Hayami K. Serum‐constituents analyses: effect of duration and temperature of storage of clotted blood. Clin Chem 1981; 27: 35–8
- Rehak N. N., Chiang B. T. Storage of whole blood: effect of temperature on the measured concentration of analytes in serum. Clin Chem 1988; 34: 2111–14
- Kratz A., Lewandrowski K. B. Case records of the Massachusetts General Hospital. Weekly clinicopathological exercises. Normal reference laboratory values. N Engl J Med 1998; 339: 1063–72
- Laessig R. H., Indriksons A. A., Hassemer D. J., Paskey T. A., Schwartz T. H. Changes in serum chemical values as a result of prolonged contact with the clot. Am J Clin Pathol 1976; 66: 598–604
- Guder W. G. NSWHZB. Collection of specimen samples: from the patient to the laboratory ‘The impact of preanalytical variables on the quality of laboratory results’. GIT VERLAG GMBH, DarmstadtGermany 2001; 36
- Berg B., Estborn B., Tryding N. Stability of serum and blood constituents during mail transport. Scand J Clin Lab Invest 1981; 41: 425–30
- Clark S., Youngman L. D., Palmer A., Parish S., Peto R., Collins R. Stability of plasma analytes after delayed separation of whole blood: implications for epidemiological studies. Int J Epidemiol 2003; 32: 125–30
- Alberts B., Johnson A., Lewis J., Raff M., Roberts K., Walter P. Membrane transport. Molecular biology of the cell, S Gibbs. Garland Science, New York 2002; 616