Method comparison between Alinity hq and Sysmex XT-4000i in an emergency laboratory

, ORCID Icon, &
Pages 31-37 | Received 21 Jul 2022, Accepted 29 Dec 2022, Published online: 09 Jan 2023

References

  • Clinical and Laboratory Standards Institute. Measurement procedure comparison and bias estimation using patient samples. Approved guideline. 3rd ed. Wayne (PA): Clinical and Laboratory Standards Institute; 2013.
  • Schober P, Boer C, Schwarte LA. Correlation coefficients. Anesth Analg. 2018;126(5):1763–1768.
  • Pum J. A practical guide to validation and verification of analytical methods in the clinical laboratory. Adv Clin Chem. 2019;90:215–281.
  • Bilić-Zulle L. Comparison of methods: passing and bablok regression. Biochem Med (Zagreb). 2011;21(1):49–52.
  • Altman DG, Bland JM. Measurement in medicine: the analysis of method comparison studies. Statistician. 1983;32(3):307–317.
  • Giavarina D. Understanding bland altman analysis. Biochem Med. 2015;25(2):141–151.
  • Fraser CG. Reference change values. Clin Chem Lab Med. 2011;50(5):807–812.
  • Technical information. Sysmex XT-4000i instructions for use. 2009.
  • Principles of operation. Abbott alinity h‐series operations manual. Santa Clara (CA): Abbott Laboratories; 2019. pp. 270–285.
  • International Standardization Organization. ISO 15189:2012(en) medical laboratories - Requirements for quality and competence. 3rd ed. Geneva, Swizerland.
  • RCV calculator available at EFLM Biological Variation Database. 2021. https://biologicalvariation.eu/
  • Statland BE. Clinical decision levels for laboratory tests. 2nd ed. Oradell (NJ): Medical Economics Books; 1987.
  • Woo KS, Jeong IH, An GD, et al. Performance evaluation of new abbott alinity hq hematology analyzer. Int J Lab Hematol. 2019;41(5):657–663.
  • Briggs C, Culp N, Davis B, International Council for Standardization in Haematology, Writing Group, et al. ICSH guidelines for the evaluation of blood cell analysers including those used for differential leucocyte and reticulocyte counting. Int J Lab Hematol. 2014;36(6):613–627.
  • Bruegel M, George TI, Feng B, et al. Multicenter evaluation of the cobas m 511 integrated hematology analyzer. Int J Lab Hematol. 2018;40(6):672–682.
  • Lifson MA, Wakui M, Arai T, et al. Alinity hq platelet results are equivalent with the international reference method in thrombocytopenic samples. Int J Lab Hematol. 2021;43(6):1357–1362.
  • Van Stralen KJ, Dekker FW, Zoccali C, et al. l. Measuring agreement, more complicated Than it seems. Nephron Clin Pract. 2012;120(3):c162–c167.
  • Ozarda Y, Sikaris K, Streichert T, IFCC Committee on Reference intervals and Decision Limits (C-RIDL), et al. Distinguishing reference intervals and clinical decision limits - A review by the IFCC committee on reference intervals and decision limits. Crit Rev Clin Lab Sci. 2018;55(6):420–431.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.