References
- Pioda L AR, Simon W, Bosshard H R, Curtis H Ch. Determination of potassium ion concentration in serum using highly selective liquid-membrane electrode. Clin Chim Acta 1970; 29: 289–93
- Hirst A D, Stevens J F. Electrodes in clinical chemistry. Ann Clin Biochem 1985; 22: 460–88
- Uesch U, Amman D, Simon W. Ion-selective electrodes for clinical use. Clin Chem 1986; 32: 1448–59
- Byrne T P. Ion-selective electrodes in direct potentiometric clinical analysers. Selective Electrode Rev 1988; 10: 107–24
- Lewenstam A. Ion-selective electrodes in clinical chemistry. State of the art. Anal Proc 1991; 28: 106–9
- Lewenstam A, Maj-Zurawska M, Hulanicki A. Application of ion-selective electrodes in clinical analysis. Electroanalysis 1991; 3: 727–34
- Oggenfuss P, Morf W E, Oesch U, Ammann D, Pretsch E, Simon W. Neutral-carrier based ion-selective electrodes. Anal Chim Acta 1986; 180: 299–311
- Ammann D, Morf W E, Anker P, Meier P C, Pretsch E, Simon W. Neutral-carrier based ion-selective electrodes. Ion-Selective Electrode Rev 1983; 5: 3–92
- Cadogan A, Gao Z, Lewenstam A, Ivaska A. All-solid-state sodium-selective electrode based on calixarene ionophore in a polyvinyl chloride) membrane with a poly-pyrrole solid contact. Anal Chem 1992; 64: 2496–501
- Maj-Zurawska M, Sokalski T, Hulanicki A. Interpretation of the selectivity and detection limit of liquid ion-exchanger electrodes. Talanta 1988; 35: 281–85
- Lewenstam A, Erkola E, Lehmenkuhler A. Studies of quaternary ammonium ion interference on potasssium ion-selective electrodes. Fresenius J Anal Chem 1993; 346: 577–79
- Payne R B, Buckley B M, Rawson K M. Protein interference with ion-selective electrode measurement depends on reference electrode composition and design. Ann Clin Biochem 1991; 28: 68–72
- Payne R B. Effects of ionic strength on ionized calcium measured using reference electrode liquid junctions of varying design and composition. Ann Clin Biochem 1991; 28: 235–39
- Saris N E. Protein does not interfere with the ion-selective electrode determination of calcium, sodium or potassium ions. J Clin Chem Clin Biochem 1988; 26: 101–4
- Lewenstam A, Ost J. Time-dependent selectivity of ion-selective electrodes used in clinical analysis. Proceedings of the 13th International Symposium on Methodology and Clinical Applications of Blood Gases, pH, Electrolytes and Sensor Technology, K Kuwa. IFCC/WGSE-JSCC/CBGE, Hakone 1992; Volume 13: 147–56
- Lewenstam A, Hulanicki A. Selectivity coefficients of ion-selective electrodes. Selective Electrode Rev 1990; 12: 161–202, and 1991; 13: 129–131 (errata)
- Sandifer J R. Silver/silver chloride electrodes coated with cellulose acetate for the elimination of bromide and uric acid interferences. Anal Chem 1981; 53: 1164–70
- Trojanowicz M, Matuszewski W. Potentiometric flow-injection determination of chlorides. Anal Chim Acta 1983; 51: 77–84
- Lewenstam A, Saarinen K-S, Hulanicki A. Theoretical and practical aspects of ISE selectivity in clinical analysis. Methodology and clinical applications of ion-selective electrodes, A HJ Maas, B Buckley, H Marsoner, N-E L Saris, R Sprokholt. IFCC Workshop, Graz 1986; Volume 8: 151–158
- Wangsa J, Arnold M A. Selectivity properties of sodium glass membrane electrodes under non-steady-state conditions. Anal Chem 1987; 59: 1604–8
- Maj-Zurawska M, Lewenstam A. Fully automated potentiometric determination of ionized magnesium in blood serum. Anal Chim Acta 1990; 236: 331–35