REFERENCES
- Jansen RTP, Blaton V, Burnett D, Queralto JM, Huisman W. Quality and accreditation systems in clinical biochemistry in the European Union. Eur J Clin Chem Clin Biochem 1995; 33: 393–8.
- Dybkaer R. Quality assurance, accreditation, and certification: needs and possibilities. Clin Chem 1994; 40: 1416–20.
- Lasky FD. Achieving accuracy for routine clinical chemistry methods by using patient specimen correlations to assign calibrator values: a means of managing matrix effects. Arch Pathol Lab Med 1993; 117: 412–9.
- Eckfeldt JH, Copeland KR. Accuracy verification and identification of matrix effects. The College of American Pathologists' protocol. Arch Pathol Lab Med 1993; 117: 381–6.
- Lawson NS, Williams TL, Long T. Matrix effects and accuracy assessment. Identifying matrix-sensitive methods from real-time proficiency test-ing data. Arch Pathol Lab Med 1993; 117:401–11.
- Miller WG. How useful are reference materials [editorial]? Clin Chem 1996; 42: 1733–4.
- Thienpont LM, v. Nuwenborg JE, Stöckl D. Ion Chromatogarphy as potential reference method-ology for the determination of total calcium and magnesium in serum. Analyt Chem 1994; 66: 2404–8.
- Thienpont LM, v. Nuwenborg JE, Reinauer H, Stöckl D. Validation of candidate reference methods based on ion chromatography for deter-mination of total sodium, potassium, calcium and magnesium in serum through comparison with flame atomic emission and absorption spectrom-etry. Clin Biochem 1996; 29: 501–8.
- Stöckl D, Reinauer H. Candidate reference methods for determining target values for choles-terol, creatinine, uric acid, and glucose in external quality assessment and internal accuracy control. I Method setup. Clin Chem 1993, Vol 39, No.6: 993–1000.
- Thienpont LM, de Leenheer AP, Stöckl D, Reinauer H. Candidate reference methods for determining target values for cholesterol, creati-nine, uric acid, and glucose in external quality assessment and internal accuracy control. II Method transfer. Clin Chem 1993; 39: 1001–6.
- Stöckl D, Reinauer H, Appel W, von Klein-Wiesenberg A. Diskussionsvorschlag fr em n ein-heitliches Referenzmethodenkonzept auf der Grundlage der `Richtlinien der Bundesärrz-tekammer zur Qualitätssicherung in medizin-schen Laboratorien'. Lab Med 1991; 15: 336–9.
- Stöckl D, Reinauer H. Development of criteria for the evaluation of reference method values. Scand J Clin Lab Invest 1993; 53 Suppl 212: 16–8.
- Tonks DB. A study of accuracy and precision of clinical chemistry determinations in 170 Canadian laboratories. Clin Chem 1963; 9: 217–33.
- Richtlinjen der Bundesärztekammer zur Quali-tätssicherung in medizinischen Laboratorien. Dtsch Ärztebl 1988; 85: A699–712.
- Koch DD, Oryall JJ, Quam EF, Feldbruegge DH, Dowd DE, Barry PL, Westgard JO. Selection of medically useful quality-control procedures for individual tests done in a multitest analytical system. Clin Chem 1990; 36: 230–3.
- Department of Health and Human Services. Medicare, Medicais and CLIA programs; regula-tions implementing the Clinical Laboratory Improvement Amendments of 1988 (CLIA). Fed Regist, Feb 28, 1922; 57: 7002–186.
- Fraser CG, Hyltoft Petersen P, Ric6s C, Haeckel R. Proposed quality specifications for the impre-cision and inaccuracy of analytical systems for clinical chemistry. Eur J Clin Chem Clin Bio-chem 1992; 30: 311–7.
- Ric& C, Baadenhuijsen H, Libeer J-C, Hyltoft Petersen P, Stöckl D, Thienpont LM, Fraser CG. External quality assessment: currently used crite-ria for future harmonization. Eur J Clin Chem Clin Biochem 1996; 34: 159–65.
- Analytical quality goals. Report. Labquality 1995.
- Stöckl D, Libeer J-C, Reinauer H, Thienpont LM, De Leenheer AP. Accuracy-based assessment of proficiency testing results with serum from single donations: possibilities and limitations. Clin Chem 1996; 42: 469–70.