REFERENCES
- Severinghaus JW. Historical development of oxyge-nation monitoring. In: Payne JP, Severinghaus JW, editors. Pulse oximetry. Springer-Verlag, 1986; 12.
- Hunt TK. A new method of determining tissue oxygen tension. Lancet 1964; 2: 1370–1.
- Niinikoski J, Hunt TK. Measurement of wound oxygen with implanted Silastic tube. Surgery 1972; 71: 22–6.
- Hjortdal VE, Timmenga EJ, KjOlseth D, Henriksen TB, Hansen ES, Djurhuus JC, et al. Continuous direct tissue oxygen tension measurement. Ann Chir Gyn 1991; 80: 8–13.
- Vrouenraets BC, Kroon BBR, van de Merve SA, Klaase JM, Broekmeyer-Reurink MP, van Slooten GW, et al. Physiological implications of hyperbaric oxygen tension in isolated limb per-fusion using melphalan: a pilot study. Eur Surg Res 1996; 28: 235–44.
- Gottrup F, Firmin R, Chang N, Goodson III WH, Hunt TK. Continuous direct tissue oxygen ten-sion measurement by a new method using an implantable Siliastic tonometer and oxygen pol-arography. Am J Surg 1983; 146: 399–403.
- Gottrup F, Gellett S, Kirkegaard L, Stender Hansen E, Johannsen G. Continuous monitoring of tissue oxygen tension during hyperoxia and hypoxia: relation of subcutaneous, transcutane-ous, and conjunctival oxygen tension to hemody-namic variables. Crit Care Med 1988; 12: 1229–34.
- Fatt I. Polarographic oxygen sensors. Its theory of operation and its application in biology, medicine and technology. Cleveland: C.R.C. Press, 1976
- Venkatesh B, Clutton Brock TH, Hendry SP. A multiparameter sensor for continuous intra-arterial blood gas monitoring: a prospective evaluation. Crit Care Med 1994; 22: 588-94. Comments: Crit Care Med 1995; 23: 788–9.
- Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 8: 307–10.
- Scherjon SA, Kok JH, Oosting H, Zondervan HA. Intra-observer and inter-observer reliability of the pulsatility index calculated from pulsed Doppler flow velocity waveforms in three fetal vessels. Br J Obstet Gynaecol 1993; 100: 134–8.
- Jönsson K, Jensen JA, Goodson III WE, West JM, Hunt TK. Assessment of perfusion in postopera-tive patients using tissue oxygen measurements. Br J Surg 1987; 74: 263–7.
- Hartmann M, Montgomery A, Jönsson K, Haglund U. Tissue oxygenation in hemorrhagic shock measured as transcutaneous oxygen tension, subcutaneous oxygen tension and gastro-intestinal intramucosal pH in pigs. Crit Care Med 1991; 19: 205–10.
- Drucker W, Pearce F, Glass-Heidenreich L, Hopf H, Powell C, Ochsner MG, et al. Subcutaneous tissue oxygen pressure: a reliable index of peri-pheral perfusion in humans after injury. J Trauma 1996; 40 Suppl: 116–22.
- Brantigan JW, Ziegler EC, Hynes KM, Miyazawa TY, Smith AM. Tissue gases during hypovolemic shock. J Appl Physiol 1974; 37: 117–22.
- Keeler C, McLane C, Covey M, Smith N, Holm K. A review of infection control practices related to intravascular pressure monitoring devices. Heart & Lung 1987; 16: 201–6.
- Chang N, Goodson WH, Gottrup F, Hunt TK. Direct measurement of wound and tissue oxygen tension in postoperative patients. Ann Surg 1983; 197: 470–8.
- Larsen PN, Moesgaard F, Gottrup F, Helledie N. Characterization of the silicone tonometer using a membrane-covered transcutaneous electrode. Scand J Clin Lab Invest 1989; 49: 513–9.
- Hjortdal V, Henriksen TB, Kjølseth D, Hansen ES, Djurhuus JC, Gottrup F. Tissue oxygen tension in myocutaneous flaps. Eur J Surg 1991; 157: 307–11.
- Gottrup F, Firmin R, Rabkin J, Halliday BJ, Hunt T. Directly measured tissue oxygen tension and arterial oxygen tension assess tissue per-fusion. Crit Care Med 1987; 15: 1030–6.
- Hartmann M, Rosberg B, Jönsson K. The influ-ence of different levels of PEEP on peripheral tissue perfusion measured by subcutaneous and transcutaneous oxygen tension. Int Care Med 1992; 18: 474–8.
- Hjortdal V, Awwad AM, Gottrup F, Kirkegaard L, Gellett S. Tissue oxygen tension measurement for monitoring musculocutaneous and cutaneous flaps. Scand J Plast Reconstr Hand Surg 1990; 24: 27–30.
- Sheffield CW, Sessler DI, Hunt TK, Scheuenstuhl H. Mild hypothermia during halothane-induced anesthesia decreases resistance to Staphylococcus aureus dermal infection in guinea pigs. Wound Rep Reg 1994; 2: 48–56.
- Sheffield CW, Sessler DI, Hunt TK. Mild hypo-thermia during isoflurane anesthesia decreases resistance to E. coli dermal infection in guinea pigs. Acta Anaesthesiol Scand 1994; 38: 201–5.
- Salo M. Hypothermia and infection [Editorial]. Acta Anaesthesiol Scand 1994; 38: 199–200.
- Rabkin JM, Hunt TK. Local heat increases blood flow and oxygen tension in wounds. Arch Surg 1987; 122: 221–5.