References
- Ge PS, Raju GS. Rupture and perforation of the esophagus. The Esophagus. 6th ed. Oxford (UK): Wiley Blackwell; 2021. Chapter 45, p.769–788.
- Muhammad H, Umar S, Ahmad S, et al. A comparison of single bite and double bite biopsy techniques in gastrointestinal endoscopy: a scoping review. J Gastroenterol Res. 2022;6:229–233.
- Frimberger E, Becker P, Roesch T, et al. 7121 Double bite biopsy – a method to save biopsy time in endoscopy. Gastrointest Endosc. 2000;51(4):AB272.
- Padda S, Shah I, Ramirez FC. Adequacy of mucosal sampling with the “two-bite” forceps technique: a prospective, randomized, blinded study. Gastrointest Endosc. 2003;57(2):170–173.
- Rizzo J, Bernstein D, Gress F. A performance, safety and cost comparison of reusable and disposable endoscopic biopsy forceps: a prospective, randomized trial. Gastrointest Endosc. 2000;51(3):257–261.
- Zaidman JS, Frederick WG, Furth EE, et al. Comparison of pelican single-use multibite biopsy forceps and traditional double-bite forceps: evaluation in a porcine model. Gastrointest Endosc. 2006;64(4):582–588.
- Fantin AC, Neuweiler J, Binek JS, et al. Diagnostic quality of biopsy specimens: comparison between a conventional biopsy forceps and multibite forceps. Gastrointest Endosc. 2001;54(5):600–604.
- Hookey LC, Hurlbut DJ, Day AG, et al. One bite or two? A prospective trial comparing colonoscopy biopsy technique in patients with chronic ulcerative colitis. Can J Gastroenterol. 2007;21(3):164–168.
- Latorre M, Lagana SM, Freedberg DE, et al. Endoscopic biopsy technique in the diagnosis of celiac disease: one bite or two? Gastrointest Endosc. 2015;81(5):1228–1233.
- Pappas A, Tan WK, Waldock W, et al. Single-bite versus double-bite technique for mapping biopsies during endoscopic surveillance for hereditary diffuse gastric cancer: a single-center, randomized trial. Endoscopy. 2021;53(3):246–253.
- Dupont WD, Plummer WD. Power and sample size calculations: a review and computer program. Control Clin Trials. 1990;11(2):116–128.
- Chu KM, Yuen ST, Wong WM, et al. A prospective comparison of performance of biopsy forceps used in single passage with multiple bites during upper endoscopy. Endoscopy. 2003;35(4):338–342.
- Edery EG, Scase T, Kisielewicz C, et al. Comparison of standard single-bite with multiple-bite biopsy forceps for collection of gastrointestinal biopsies in dogs: a prospective study. Vet Rec. 2018;183(20):624.
- Cartwright JA, Hill TL, Smith S, et al. Evaluating quality and adequacy of gastrointestinal samples collected using reusable or disposable forceps. J Vet Intern Med. 2016;30(4):1002–1007.
- Goutal-Landry CM, Mansell J, Ryan KA, et al. Effect of endoscopic forceps on quality of duodenal mucosal biopsy in healthy dogs. J Vet Intern Med. 2013;27(3):456–461.
- Ruiz GC, Reyes‐Gomez E, Hall EJ, et al. Comparison of 3 handling techniques for endoscopically obtained gastric and duodenal biopsy specimens: a prospective study in dogs and cats. J Vet Intern Med. 2016;30(4):1014–1021.