REFERENCES
- Hand , C. W. , Allen , M. C. , Mcquay , H. J. , Moore , R. A. and Sear , J. W. 1987 . Analysis of Morphine and its Major Metabolites by Differential Radioimmunoassay . Ann. Clin. Biochem. , 24 : 153 – 160 .
- Quinn , k. , Shill , A. , Robertson , S. , Ness , C. , Galloway , D. B. and Leslie , S. T. 1988 . Determination of Morphine in Human-Plasma by Radioimmunoassay Utilizing a Preliminary Liquid Solid Extraction . J. Pharm. Biomed. Anal. , 6 : 15 – 22 .
- Schuberth , J. 1989 . Gas Chromatographic-Mass spectrometric determination of Morphine, Codeine and 6-Monoacetylmorphine in Blood Extracted by Solid-Phase . J. Chromatogr.-Biomed. Appl. , 490 : 444 – 449 .
- Chen , B. H. , Taylor , E. H. and Pappas , A. A. 1990 . Comparison of Derivatives for Determination of Codeine and Morphine by Gas chromatography/Mass Spectrometry . J. Anal. Toxic. , 14 : 12 – 17 .
- Tagliaro , F. , Campagnari , G. , Carli , G. , Cristofori , F. and Mango , M. 1988 . HPLC Determination of Morphine with Amperometric Detection at Low Potentials under Basic pH Conditions . Chromatographia , 26 : 163 – 167 .
- Abbott , R. W. , Gill , R. and Townshend , A. 1987 . Determination of Morphine in Body-Fluids by High-Performance Liquid-Chromatography with Chemiluminescence Detection . Analyst. , 112 : 397 – 406 .
- Abbott , R. W. , Gill , R. and Townshend , A. 1986 . Determination of Morphine by Flow-Injection Analysis with Chemiluminescence Detection . Analyst , 111 : 635 – 640 .
- Wintersteiger , R. 1982 . Determination of Morphine and Morphine-6-Nicotinate by an Insitu Reaction on the Chromatographic Plates with Dansyl Chloride . Analyst. , 107 : 459 – 461 .
- Tagliaro , F. , Frigerio , A. , Dorizzi , R. , Marigo , M. and Lubli , G. 1985 . Liquid-Chromatography with Pre-Column Dansyl Derivatization and Fluorimetric Detection Applied to the Assay of Morphine in Biological Samples . J.Chromatogr. , 330 : 323 – 331 .
- Wang , S. Y. , Poon , M. K. and Tham , S. Y. 1986 . Thin-Layer chromatographic and Column Liquid-Chromatographic Analyses of Morphine in Urine via Dabsylation . J.Chromatogr.-Biomed. Appl. , 381 : 331 – 341 .
- Wintersteiger , R. and Zeipper , U. 1982 . Fluorimetric Determination of Morphine and Diamorphine . Arch. Pharm. , 315 : 657 – 661 .
- Takemori , A. E. 1968 . An Ultrasensitive Method for the Determination of Morphine and its Application in Experiments in Vitro and Vivo . Biochem. Pharmacol. , 17 : 1627 – 1635 .
- Nelson , P. E. 1984 . High-Performance Liquid-Chromatography Detection of Morphine by Fluorescence After Post-column Derivatization . J. Chromatogr. , 298 : 59 – 65 .
- Nelson , P. E. , Nolan , S. L. and Bedford , K. R. 1982 . High-Performance Liquid-Chrpmatography Detection of Morphine by Fluorescence After Post-column Derivatization . J.Chromatogr. , 234 : 407 – 414 .
- Darwin , W. D. and Cone , E. J. 1980 . Fluorescence Properties of Pseudomorphine and Congeners: Structure-Activity Relationships . J. Pharm. Sci. , 69 : 253 – 257 .