References
- Kousa P, Järvinen TL, Vihavainen M, et al. The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction. Part I: femoral site. Am J Sports Med. 2003;31:174–181.
- Brand J Jr, Weiler A, Caborn DN, et al. Graft fixation in cruciate ligament reconstruction. Am J Sports Med. 2000;28:761–774.
- Bedi A, Kawamura S, Ying L, et al. Differences in Tendon graft healing between the intra-articular and extra-articular ends of a bone tunnel. Hss J. 2009;5:51–57.
- Giorgio N, Moretti L, Pignataro P, et al. Correlation between fixation systems elasticity and bone tunnel widening after ACL reconstruction. Muscles Ligaments Tendons J. 2016;6:467–472.
- Mae T, Kuroda S, Matsumoto N, et al. Migration of endobutton after anatomic double-bundle. Arthroscopy. 2011;27:1528–1535.
- Uchida R, Mae T, Matsumoto N, et al. The effect of cortical button location on its postoperative. Knee Surg Sports Traumatol. 2014;22:1047–1054.
- Sonnery-Cottet B, Rezende FC, Martins Neto A, et al. Arthroscopically confirmed femoral button deployment. Arthrosc Tech. 2014;2014(3):309–312.
- Perumal R, Gunasekaran C, Jacob M, et al. Alternate method of arthroscopically confirming femoral button deployment for knee anterior cruciate ligament graft suspensory cortical fixation. Arthrosc Tech. 2018;7:1295–1298.
- Patel SD, Boxley PJ, Kang RW. Arthroscopic anterior cruciate ligament femoral tunnel visualization for button fixation. Arthrosc Tech. 2017;6:585–589.
- Nag HL, Gupta H. Seating of tightRope RT button under direct arthroscopic visualization in anterior cruciate ligament reconstruction to prevent potential complications. Arthrosc Tech. 2012;1:83–85.
- Ohnishi Y, Chang A, Utsunomiya H, et al. Arthroscopic technique to reduce suture button migration during anterior cruciate ligament reconstruction procedure. Arthrosc Tech. 2017;6:1927–1931.
- Lubowitz JH, Ahmad CS, Anderson K. All-inside anterior cruciate ligament graft-link technique: second-generation, no-incision anterior cruciate ligament reconstruction. Arthroscopy. 2011;27:717–727.
- Toftoy AC, Rud CT, Deden AA, et al. Femoral cortical button malposition rates in anterior cruciate ligament reconstruction: a retrospective review. Orthopedics. 2019;42:56–60.
- Irrgang JJ, Anderson AF, Boland AL, et al. Development and validation of the international knee documentation committee subjective knee form. Am J Sports Med. 2001;29:600–613.
- Lysholm J, Gillquist J. Evaluation of knee ligament surgeryresults with special emphasis on use of a scoring scale. Am J Sports Med. 1982;10:150–154.
- Daniel DM, Stone ML, Sachs R, et al. Instrumented measurement of anterior knee laxity in patients with acute anterior cruciate ligament disruption. Am J Sports Med. 1895;13:401–407.
- Boyle MJ, Vovos TJ, Walker CG, et al. Does adjustable-loop femoral cortical suspension loosen after anterior cruciate ligament reconstruction? A retrospective comparative study. Knee. 2015;22:304–308.
- Simonian PT, Behr CT, Stechschulte DJ Jr, et al. Potential pitfall of the endoButton. Arthroscopy. 1998;14:66–69.
- Muneta T, Yagishita K, Kurihara Y, et al. Intra-articular detachment of the endobutton more than 18 months after anterior cruciate ligament reconstruction. Arthroscopy. 1999;15:775–778.
- Yanmis I, Tunay S, Oguz E, et al. Dropping of an endoButton into the knee joint 2 years after anterior cruciate ligament repair using proximal fixation. Arthroscopy. 2004;20:641–643.