310
Views
6
CrossRef citations to date
0
Altmetric
Original Articles

A Review of Correlations for Outside Boiling of Ammonia on Single Tube and Bundles

, , , &

References

  • B. Bolaji and Z. Huan, “Ozone depletion and global warming: Case for the use of natural refrigerant–a review,” Renew Sustainable Energy Rev., vol. 18, no. C, pp. 49–54, 2013. ( article)
  • M. Ohadi, S. Li, R. Radermacher, and S. Dessiatoun, “Critical review of available correlations for two-phase flow heat transfer of ammonia,” Int. J. Refrig., vol. 19, no. 4, pp. 272–284, 1996. ( article)
  • G. Lorentzen, “Ammonia: an excellent alternative,” Int. J. Refrig., vol. 11, no. 4, pp. 248–252, 1988. ( article)
  • W. Stoecker, “Comparison of ammonia with other refrigerants for district cooling plant chillers,” ASHRAE Trans., vol. 100, no. 1, pp. 1126–1135, 1994. ( article)
  • R. Cole, “Ammonia as a refrigerant in light of the CFC phase-out,” ASHRAE J., vol. 32, no. 12, pp. 28–32, 1990. ( article)
  • S. M. Miner, “Ammonia as a refrigerant of choice,” ASHRAE J., vol. 32, no. 12, pp. 43–44, 1990. ( article)
  • R. S. Ohling, “Ammonia; The new/old refrigerant,” ASHRAE J., vol. 32, no. 12, pp. 34–42, 1990. ( article)
  • P. C. Koelet, and T. B. Gray, Industrial Refrigeration: Principles, Design and Applications, vol. 78, London, UK: Macmillan, 1992. ( Book)
  • K. Starner, “Heat exchangers for ammonia water chillers: Design considerations and research needs,” Proc. ASHRAE/NIST Refrigerants Conference, Atlanta, GA, pp. 85–89, August 1993. ( proceedings)
  • G. Lorentzen, “The use of natural refrigerants: a complete solution to the CFC/HCFC predicament,” Int. J. Refrig., vol. 18, no. 3, pp. 190–197, 1995. ( article)
  • Z. Ayub, “Industrial refrigeration and ammonia enhanced heat transfer,” J. Enhanc. Heat Transfer, vol. 13, no. 2, pp. 157–173, 2006. ( article)
  • Z. H. Ayub, “Natural Refrigerants: Present and future trend toward “Green” solution,” Heat Transfer Eng., vol. 28, no. 7, pp. 605–607, 2007. ( article)
  • Z. Ayub, “Current and future prospects of enhanced heat transfer in ammonia systems,” Int. J. Refrig., vol. 31, no. 4, pp. 652–657, 2008. ( article)
  • X. Zeng, M.-C. Chyu, and Z. H. Ayub, “Evaporation heat transfer performance of nozzle-sprayed ammonia on a horizontal tube,” ASHRAE Trans., vol. 101, no. 1, pp. 136–149, 1995. ( article)
  • X. Zeng, M.-C. Chyu, and Z. H. Ayub, “Performance of nozzle-sprayed ammonia evaporator with square-pitch plain-tube bundle,” ASHRAE Trans., vol. 103, no. 2, pp. 68–81, 1997. ( article)
  • X. Zeng, M. Chyu, and Z. H. Ayub, “Ammonia spray evaporation heat transfer performance of single low-fin and corrugated tubes/Discussion,” ASHRAE Trans., vol. 104, no. 1, pp. 185–196, 1998. ( article)
  • X. Zeng, M.-C. Chyu, and Z. Ayub, “Experimental investigation on ammonia spray evaporator with triangular-pitch plain-tube bundle, Part II: evaporator performance,” Int. J. Heat Mass Transfer, vol. 44, no. 11, pp. 2081–2092, 2001. ( article)
  • T. J. Rabas, and H. Mitchell, “Internally enhanced carbon steel tubes for ammonia chillers,” Heat Transfer Eng., vol. 21, no. 5, pp. 3–16, 2000. ( article)
  • Z. H. Ayub, “Ammonia refrigeration heat transfer enhancement,” Heat Transfer Eng., vol. 25, no. 5, pp. 4–5, 2004. ( article)
  • Z. Ayub, M.-C. Chyu, and A. Ayub, “Case study: Limited charge shell and tube ammonia spray evaporator with enhanced tubes,” Appl. Therm. Eng., vol. 26, no. 11, pp. 1334–1338, 2006. ( article)
  • Z. H. Ayub, M.-C. Chyu, and A. H. Ayub, “Different types of carbon steel enhanced tubes in ammonia flooded evaporator,” Heat Transfer Eng., vol. 27, no. 5, pp. 39–44, 2006. ( article)
  • S. Kotthoff, and D. Gorenflo, “Pool boiling heat transfer to hydrocarbons and ammonia: A state-of-the-art review,” Int. J. Refrig., vol. 31, no. 4, pp. 573–602, 2008. ( article)
  • K. Spindler, “Overview and discussion on pool boiling heat transfer data and correlations of ammonia,” Int. J. Refrig., vol. 33, no. 7, pp. 1292–1306, 2010. ( article)
  • I. Mostinski, “Application of the rule of corresponding states for calculation of heat transfer and critical heat flux,” Teploenergetika, vol. 4, no. 4, pp. 66–71, 1963. ( article)
  • K. Stephan, and P. Preusser, “Heat transfer and critical heat flux in pool boiling of binary and ternary mixtures,” Ger. Chem. Eng., vol. 2, no. 3, pp. 161–169, 1979. ( article)
  • D. Gorenflo, Pool boiling, VDI Heat Atlas (English version), VDI-Verlag GmbH, Dusseldorf, Germany, Springer, 1993. ( chapter in a book)
  • R. Ciconkov, and Z. H. Ayub, “New technologies in ammonia refrigerating and air-conditioning systems,” Heat Transfer Eng., vol. 30, no. 4, pp. 324–329, 2009. ( article)
  • G. Ribatski, and J. R. Thome, “Two-phase flow and heat transfer across horizontal tube bundles‐A review,” Heat Transfer Eng., vol. 28, no. 6, pp. 508–524, 2007. ( article)
  • M. Cooper, “Heat flow rates in saturated nucleate pool boiling-a wide-ranging examination using reduced properties,” Adv. Heat Transfer, vol. 16, pp. 157–239, 1984. ( article)
  • J. C. Chen, “Correlation for boiling heat transfer to saturated fluids in convective flow,” Ind. Eng. Chem. Process Des. Dev., vol. 5, no. 3, pp. 322–329, 1966. ( article)
  • K. Stephan and M. Abdelsalam, “Heat-transfer correlations for natural convection boiling,” Int. J. Heat Mass Transfer, vol. 23, no. 1, pp. 73–87, 1980. ( article)
  • D. Gorenflo, “State of the art in pool boiling heat transfer of new refrigerants,” Int. J. Refrig., vol. 24, no. 1, pp. 6–14, 2001. ( article)
  • M. M. Shah, “A general correlation for heat transfer during saturated boiling with flow across tube bundles,” HVAC&R Res., vol. 13, no. 5, pp. 749–768, 2007. ( article)
  • I. Consley, “Heat transfer in ammonia shell and tube brine coolers as affected by operating conditions,” J. ASRE, vol. 35, no. 6, pp. 409–416, 1938. ( article)
  • A. Kuprianova, “Heat transfer with pool boiling of ammonia on horizontal tubes,” Kholodiln. Tekh, vol. 47, no. 11, pp. 40–44, 1970. ( article)
  • H. Arima, M. Monde, and Y. Mitsutake, “Heat transfer in pool boiling of ammonia/water mixture,” Heat Mass Transfer, vol. 39, no. 7, pp. 535–543, 2003. ( article)
  • M. Shah, “Heat transfer and pressure drop in ammonia evaporators,” ASHRAE Trans., vol. 80, no. 2, pp. 238–254, 1974. ( article)
  • A. Malek, and R. Colin, “Ebullition de l'ammoniac en tube long, transfert de chaleur et ertes de charges en tubes vertical et horizontal,” Centre technique des. Industries Mecanniques, Senlis France, CETIM-14-011, pp. 1–65, 1983. ( Report)
  • J. Zheng, G. Jin, M.-C. Chyu, and Z. Ayub, “Flooded boiling of ammonia with miscible oil outside a horizontal plain tube,” HVAC&R Res., vol. 7, no. 2, pp. 185–204, 2001. ( article)
  • J. Fernández-Seara, Á. Á. Pardiñas, and R. Diz, “Heat transfer enhancement of ammonia pool boiling with an integral-fin tube,” Int. J. Refrig., vol. 69, pp. 175–185, 2016. ( article)
  • G. Danilova, V. Dyundin, A. Borishanskaya, A. Soloviyov, Y. A. Vol'nykh, and A. Kozyrev, “Effect of surface conditions on boiling heat transfer of refrigerants in shell-and-tube evaporators,” Heat Transfer-Soviet Res.;(USA), vol. 22, no. 1, pp. 56–65, 1990. ( article)
  • J. Fernández-Seara, Á. A. Pardiñas, and R. Diz, “Experimental heat transfer coefficients of pool boiling and spray evaporation of ammonia on a horizontal plain tube,” Int. J. Refrig., vol. 67, pp. 259–270, 2016. ( article)
  • G. Koster, “Energy savings in ammonia refrigeration plant by using oil scrubbers,” Aust. Refrig., Air Cond. Heating, vol. 40, pp. 28–32, 1986. ( article)
  • M. Shah, “Visual observations in an ammonia evaporator,” ASHRAE Trans., vol. 81, no. 1, pp. 295–306, 1975. ( article)
  • J. Chaddock, and G. Buzzard, “Effect of oil on heat transfer and pressure drop in refrigerant evaporators-Phase II: R-717”, Duke University Department of Mechanical Engineering and Materials Science, Durham, NC, ASHRAE RP 224-2, 1983. ( Report)
  • N. Hewitt, and J. McMullan, “The replacement of cfcs in refrigeration equipment by environmentally benign alternatives,” Appl. Therm. Eng., vol. 17, no. 8–10, pp. 955–972, 1997. ( article)
  • J. Zheng, G. Jin, M.-C. Chyu, and Z. Ayub, “Boiling of ammonia/lubricant mixture on a horizontal tube in a flooded evaporator with inlet vapor quality,” Exp. Therm. Fluid Sci., vol. 30, no. 3, pp. 223–231, 2006. ( article)
  • J. Zheng, M.-C. Chyu, and Z. Ayub, “Boiling of ammonia/lubricant mixture on a horizontal enhanced tube in a flooded evaporator with inlet vapor quality,” Int. J. Refrig., vol. 31, no. 4, pp. 564–572, 2008. ( article)
  • G. Danilova, V. Dyundin, and A. Soloviyov, “Heat transfer in boiling of R 717 and R 22 refrigerants on multirow tube bundles,” Heat Transfer Res., vol. 24, no. 7, pp. 889–893, 1992. ( article)
  • X. Zeng, M.-C. Chyu, and Z. Ayub, “Experimental investigation on ammonia spray evaporator with triangular-pitch plain-tube bundle, Part I: tube bundle effect,” Int. J. Heat Mass Transfer, vol. 44, no. 12, pp. 2299–2310, 2001. ( article)
  • M.-C. Chyu, J. Zheng, and Z. Ayub, “Bundle effect of ammonia/lubricant mixture boiling on a horizontal bundle with enhanced tubing and inlet quality,” Int. J. Refrig., vol. 32, no. 8, pp. 1876–1885, 2009. ( article)

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.