211
Views
3
CrossRef citations to date
0
Altmetric
Articles

Two-photon polymerization/micromolding of microscale barbs for medical applications

, , , , , & show all
Pages 387-398 | Received 23 May 2011, Accepted 23 Jan 2012, Published online: 10 Aug 2012

References

  • Peng HT, Shek PN. Novel wound sealants: biomaterials and applications. Expert Review Medical Devices. 2010;7:639–659.
  • Schmitt OH, Some interesting and useful biomimetic transforms. In: Proceedings of the 3rd International Biophysics Congress, Boston, MA; 1969: 297.
  • Vincent JFV. Selected natural materials in history. Journal of Bionic Engineering. 2005;2:161–176.
  • Hesselberg T. Biomimetics and the case of the remarkable ragworms. Naturwissenschaften. 2007;94:613–21.
  • de Mestral G. Separable fastening device, US Patent No. 3009235; 1961.
  • Russell AP, Johnson MK, Delannoy SM. Insights from studies of gecko-inspired adhesion and their impact on our understanding of the evolution of the gekkotan adhesive. Journal of Adhesion Science and Technology. 2007;21:1119–43.
  • Aksak B, Murphy MP, Sitti M. Adhesion of biologically inspired vertical and angled polymer microfiber arrays. Langmuir. 2007;23:3322–32.
  • Kim S, Sitti M, Xie T, Xiao X. Reversible dry adhesives with thermally controllable adhesion. Soft Matter. 2009;5:3689–93.
  • Lindsay JD, Chen FJ, Yu L, Efremova N. Nanofabricated gecko-like fasteners with adhesive hairs for disposable absorbent articles, US Patent No. 7811272; 2010.
  • Glass P, Chung HY, Washburn NR, Sitti M. Enhanced wet adhesion and shear of elastomeric micro-fiber arrays with mushroom tip geometry and a photopolymerized p(DMA-co-MEA) tip coating. Langmuir. 2010;26:17357–62.
  • Arul EP, Ghatak A. Bioinspired design of a hierarchically structured adhesive. Langmuir. 2009;25:611–7.
  • Majumder A, Sharma A, Ghatak A. A bioinspired wet/dry microfluidic adhesive for aqueous environments. Langmuir. 2010;26:521–5.
  • Arul EP, Ghatak A. Adhesives with patterned subsurface microstructures. Journal of Materials Science. 2011;46:832–8.
  • Roberts D. Velcro closure material in wound repair. Veterinary Medicine & Small Animal Clinician. 1967;62:747.
  • Krackow KA. A maneuver for improved positioning of a tourniquet in the obese patient. Clinical Orthopaedics Related Research. 1982;168:80–82.
  • Wittmann DH, Aprahamian C, Bergstein JM. Etappenlavage: advanced diffuse peritonitis managed by planned multiple laparotomies utilizing zippers, slide fastener, and Velcro analogue for temporary abdominal closure. World Journal of Surgery. 1990;14:218–26.
  • Wicher GC, Hadley DA, Oottamasathien SN, Wallis MC, de Vries CR, Snow BW, Cartwright PC. Padded velcro strap (modified mermaid) immobilization following newborn exstrophy closure. Journal of Urology. 2009;181:402.
  • Allieu Y, Romieu C. The use of Jenning's barb wire in tendon sutures absence of postoperative immobilization. Annales de Chirurgie. 1971;25:987–94.
  • Meyrueis JP, Poupée JC, Cameli M, Vialla JM, Boudry M. Steel wire with hook or ‘barb wire’. Its use in hand surgery. Journal of de Chirurgie. 1974;107:151–60.
  • Goutallier D, Delepine G, Benazet JP. Barb wire repair of recent ruptures of the anterior cruciate ligament. Nouvelle Presse Medicale. 1980;9:3267–629.
  • Merle M. Primary repair of the collateral cubital ligament of the metacarpophalangeal articulation of the thumb using Jenning's barb-wire. Annales de Chirurgie de la Main. 1987;6:170–2.
  • Parikh PM, Davison SP, Higgins JP. Barbed suture tenorrhaphy: an ex vivo biomechanical analysis. Plastic and Reconstructive Surgery. 2009;124:1551–8.
  • Han H, Weiss LE, Reed ML. Mating and piercing micromechanical structures for surface bonding applications, In: Proceedings of the IEEE Micro Electro Mechanical Systems: An Investigation of Micro Structures, Sensors, Actuators, Machines and Robots, Salt Lake City, UT; 1991: 253–8.
  • Han H, Weiss LE, Reed ML. Micromechanical velcro. Journal of Microelectromechanical Systems. 1992;1:37–43.
  • Xie L, Brownridge SD, Ozdoganlar OB, Weiss LE. The viability of micromilling for manufacturing mechanical attachment components for medical applications. Transactions of the North American Manufacturing Research Institution of SME. 2006;34:445–52.
  • Byun S, Lim JM, Paik SJ, Lee A, Koo KI, Park S, Park J, Choi BD, Seo JM, Kim KA, Chung H, Song SY, Jeon D, Cho D. Barbed micro-spikes for micro-scale biopsy, Journal of Micromechanics and Microengineering. 2005;15:1279–84.
  • Kim G, Park S, Koo KI, Choi HI, Jung MJ, Song SY, Bang SM, Cho D. Nickel micro-spike for micro-scale biopsy using LiGA process. In: Synchrotron Radiation Instrumentation: ninth International Conference on Synchrotron Radiation Instrumentation, Daegu, Korea; 2007;879:1499–502.
  • Filiz S, Xie L, Weiss LE, Ozdoganlar OB. Micromilling of microbarbs for medical implants. International Journal of Machine Tools & Manufacture. 2008;48:459–72.
  • Reed ML, Hand H, Weiss LE. Silicon micro-velcro. Advanced Materials. 1992;4:48–51.
  • LaFratta CN, Li L, Fourkas JT. Soft-lithographic replication of 3D microstructures with closed loops. Proceedings of the National Academy of Sciences of the USA. 2006;103:8589–94.
  • Lim TW, Park SH, Yang DY, Pham TA, Lee DH, Kim DP, Chang SI, Yoon JB. Fabrication of three-dimensional SiC-based ceramic micropatterns using a sequential micromolding-and-pyrolysis process. Microelectronic Engineering. 2006;83:2475–81.
  • Mukai K, Yoshimura T, Maruo S. Micromolding of three-dimensional metal structures by electroless plating of photopolymerized resin. Japanese Journal of Applied Physics Part 1. 2007;46:2761–3.
  • Sun SF, Li ZZ, Wang PP, Huang WH. Fabrication of micro gear with new technologies. In: Proceedings of the 2009 IEEE International Conference on Mechatronics and Automation, Changchum, China; 2009: 1427–32.
  • Gittard SD, Ovsianikov A, Monteiro-Riviere NA, Lusk J, Morel P, Minghetti P, Lenardi C, Chichkov BN, Narayan RJ. Fabrication of polymer microneedles using a two-photon polymerization and micromolding process. Journal of Diabetes Science and Technology. 2009;3:304–11.
  • Gittard SD, Narayan RJ, Jin C, Ovsianikov A, Chichkov BN, Monteiro-Riviere NA, Stafslien S, Chisholm B. Pulsed laser deposition of antimicrobial silver coating on ormocer microneedles. Biofabrication. 2009;1:041001.
  • Gittard SD, Miller PR, Boehm RD, Ovsianikov A, Chichkov BN, Heiser J, Gordon J, Monteiro-Riviere NA, Narayan RJ. Multiphoton microscopy of transdermal quantum dot delivery using two photon polymerization-fabricated polymer microneedles. Faraday Discussions. 2011;149:171–185.
  • Meyer W, Schwarz R, Neurand K. The skin of domestic mammals as a model for the human skin, with special reference to the domestic pig. Current Problems in Dermatology. 1978;7:39–52.
  • Monteiro-Riviere NA, Riviere JE. The pig as a model for cutaneous pharmacology and toxicology and research. In: Tumbleson ME, Schook LB, editors. Advances in Swine in Biomedical Research. New York, NY: Plenum; 1996. p. 425–58.
  • Monteiro-Riviere NA. Ultrastructural evaluation of the porcine integument. In: Tumbleson ME, editor. Swine in Biomedical Research. New York, NY: Plenum; 1986. p. 641–55.
  • Monteiro-Riviere NA. Integument. In: Pond WG, Mersmann HJ, editors. The Biology of the Domestic Pig. Ithaca, NY: Cornell University Press; 2001. p. 625–52.
  • envisionTEC e-shell 300 series: technical data. Available from: http://www.envisiontec.com/fileadmin/pdf/MatSheet_eShell300_en_s.pdf (June 1, 2012).
  • General discussion, Faraday Discussions. 2011;149: 227–45.
  • Ingle NP, King MW, Zikry MA. Finite element analysis of barbed sutures in skin and tendon tissues. Journal of Biomechanics. 2010;43:879–86.
  • Tiainen J, Knutitila K, Veiranto M, Suokas E, Tormala P, Kaarela O, Lansman S, Ashammakhi N. Pull-out strength of multifunctional bioabsorbable ciprofloxacin-releasing polylactide-polyglycolide 80/20 tacks: an experimental study allograft cranial bone. Journal of Craniofacial Surgery. 2009;20:58–61.
  • Kneller JR, Wu CC, Watkins S, Nadeem A, Reed M, Weiss L, Feldman MD. Microfabricated device for arterial wall and atherosclerotic plaque penetration, In: Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Chicago, IL; 1997: 2277–80.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.