1,735
Views
36
CrossRef citations to date
0
Altmetric
Physical Activity, Health and Exercise

Accuracy of the wearable activity tracker Garmin Forerunner 235 for the assessment of heart rate during rest and activity

ORCID Icon, , , & ORCID Icon
Pages 895-901 | Accepted 08 Oct 2018, Published online: 17 Oct 2018

References

  • Alzahrani, A., Hu, S., Azorin-Peris, V., Barrett, L., Esliger, D., Hayes, M., … Kuoch, S. (2015). A multi-channel opto-electronic sensor to accurately monitor heart rate against motion artefact during exercise. Sensors, 15(10), 25681–25702.
  • de Rezende Barbosa, M. P. D. C., Silva, N. T. D., de Azevedo, F. M., Pastre, C. M., & Vanderlei, L. C. M. (2016). Comparison of background: SpringGreen polar ® RS800G3 ™ heart rate monitor with background: SpringGreen polar ® S810i ™ and electrocardiogram to obtain the series of RR intervals and analysis of heart rate variability at rest. Clinical Physiology and Functional Imaging, 36(2), 112–117.
  • Engström, E., Ottosson, E., Wohlfart, B., Grundström, N., & Wisén, A. (2012). Comparison of heart rate measured by Polar RS400 and ECG, validity and repeatability. Advances in Physiotherapy, 14(3), 115–122.
  • Fallow, A. B., Tarumi, T., & Tanaka, H. (2013). Influence of skin type and wavelength on light wave reflectance. Journal of Clinical Monitoring and Computing, 27, 313–317.
  • Forsberg, P., Analyseinstitut, I., Idræts-Forbund, D., & Forbund, D. A. (2012). Motionsløbere i Danmark : Portræt af danske motionsløbere. Idrættens Analyseinstitut. Retrieved from http://www.idan.dk/vidensbank/downloads/motionsloeb-i-danmark-portraet-af-de-danske-motionsloebere/b6326ae1-9d2c-4744-b5bf-9ff800a868fd
  • Gillinov, S., Etiwy, M., Wang, R., Blackburn, G., Phelan, D., Gillinov, A. M., … Desai, M. Y. (2017). Variable accuracy of wearable heart rate monitors during aerobic exercise. Medicine and Science in Sports and Exercise, 49(8), 1697–1703.
  • Lee, J. M., Kim, Y., & Welk, G. J. (2014). Validity of consumer-based physical activity monitors. Medicine and Science in Sports and Exercise, 46(9), 1840–1848.
  • Malisoux, L., Nielsen, R. O., Urhausen, A., & Theisen, D. (2015). A step towards understanding the mechanisms of running-related injuries. Journal of Science and Medicine in Sport, 18(5), 523–528.
  • Mukaka, M. M. (2012). Statistics corner: A guide to appropriate use of correlation coefficient in medical research. Malawi Medical Journal, 24(3), 69–71.
  • Nunan, D., Gay, D., Jakovljevic, D. G., Hodges, L. D., Sandercock, G. R. H., & Brodie, D. A. (2009). Validity and reliability of short-term heart-rate variability from the Polar S810. Medicine and Science in Sports and Exercise, 41(1), 243–250.
  • Parak, J., & Korhonen, I. (2014). Evaluation of wearable consumer heart rate monitors based on photopletysmography. Conference Proceedings : … Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Chicago: Annual Conference, 2014 (August 2014), 3670–3673. doi:10.1109/EMBC.2014.6944419
  • Shcherbina, A., Mattsson, C., Waggott, D., Salisbury, H., Christle, J., Hastie, T., … Ashley, E. (2017). Accuracy in Wrist-Worn, sensor-based measurements of heart rate and energy expenditure in a diverse cohort. Journal of Personalized Medicine, 7(2), 3.
  • Spierer, D. K., Rossen, Z., Litman, L. L., & Fuji, K. (2015). Validation of photoplethysmography as a method to detect heart rate during rest and exercise. Journal of Medical Engineering & Technology, 39, 264–271.
  • Stahl, S. E., An, H.-S., Dinkel, D. M., Noble, J. M., & Lee, J.-M. (2016). How accurate are the wrist-based heart rate monitors during walking and running activities? Are they accurate enough? BMJ Open Sport & Exercise Medicine, 2(1), e000106.
  • Vasconcellos, F. V. A., Seabra, A., Cunha, F. A., Montenegro, R. A., Bouskela, E., & Farinatti, P. (2015). Heart rate variability assessment with fingertip photoplethysmography and poler RS800cx as compared with electrocardiography in obese adolescents. Blood Pressure Monitoring, 20, 351–360.
  • Wallen, M. P., Gomersall, S. R., Keating, S. E., Wisløff, U., & Coombes, J. S. (2016). Accuracy of heart rate watches: Implications for weight management. PLoS ONE, 11(5), 1–9.
  • Weippert, M., Kumar, M., Kreuzfeld, S., Arndt, D., Rieger, A., & Stoll, R. (2010). Comparison of three mobile devices for measuring R-R intervals and heart rate variability: Polar S810i, Suunto t6 and an ambulatory ECG system. European Journal of Applied Physiology, 109(4), 779–786.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.