1,474
Views
65
CrossRef citations to date
0
Altmetric
Original Articles

Biosensors and Biofuel Cells

&
Pages 89-120 | Published online: 15 Apr 2013

References

  • Ahn , B.K. , Wolfson , S.K. and Yao , SJ. 1975 . An enzyme electrode for the determination of L-glutamic acid . Bioetectrochemistry and Bioenergetics , 2 : 142 – 153 .
  • Albery , W.J. , Eddowes , M.J.. , Hill , H.A.O. and Hillman , A.R. 1981 . Mechanism of the reduction and oxidation of cytochrome c at a modified gold electrode . Journal of the American Chemical Society , 103 : 3904 – 3910 .
  • Albisser , A.M. and Spencer , W.J. 1982 . Electronics and the diabetic . IEEE Transactions on Biomedical Engineering , 29 : 239 – 247 .
  • Arnold , M.A. and Rechnitz , G.A. 1981 . Selectivity enhancement of a tissue-based adenosine sensing membrane electrode . Analytical Chemistry , 53 : 575 – 578 .
  • Aston , W.J. , Scott , L.D. , Higgins , I.J. , Turner , A.P.F. and Hill , H.A.O. September 1983 . “ Enzyme based methanol sensor ” . In Proceedings, Bioelectrochemistry and Bioenergetics Symposium September , Nottingham 4–9, (in press)
  • Austin , L.G. Fuel Cells, a Review of Government-Sponsored Research, 1950-1964 , NASA SP 120 .
  • Bailey , D.L. and Riley , M. 1975 . Performance characteristics of gas-sensing membrane probes . Analyst , 100 : 145 – 156 .
  • Baum , G. and Ward , F.B. 1971 . General enzyme studies with a substrate selective electrode . Analytical Biochemistry , 42 : 487 – 493 .
  • Beghi , G. , ed. 1981 . Hydrogen: Energy Vector of the Future , London : Graham and Trotman Ltd .
  • Berman , H.J. 1974 . “ Ion selective microelectrodes: Their potential in the study of living matter ” . In Ion Selective Electrodes , Edited by: Berman , H.J. and Herbert , N.C. 3 – 11 . New York : Plenum Press .
  • Brown , K.T. and Flaming , D.G. 1974 . Beveling of fine micropipette electrodes by rapid precision method . Science , 185 : 693 – 695 .
  • Carr , P.W. and Bowers , L.D. 1980 . Immobilised Enzymes in Analytical and Clinical Chemistry , New York : John Wiley .
  • Cenek , M. 1968 . Biochemical fuel cells . translated from Chemiche Listy , 62 : 927 – 974 . US Air Force AD 694072. August 1969.
  • Chotani , G. and Constantinides , A. 1982 . On line glucose analyser for fermentation studies . Biotechnology and Bioengineering , 24 : 2743 – 2745 .
  • Chua , K.S. and Tan , I.K. 1978 . Plasma glucose measurements with the Yellow Springs Glucose Analyser . Clinical Chemistry , 24 : 150 – 352 .
  • Clark , L.C. and Lyons , C. 1962 . Electrode systems for continuous monitoring in cardiovascular surgery . Annals of the New York Academy of Sciences , 102 : 29 – 45 .
  • Cohen , B. 1931 . The bacterial cell as an electrical half cell . Journal of Bacteriology , 21 : 18 – 19 .
  • Cserfalvi , T. and Guilbault , G.G. 1976 . An enzyme electrode based on immobilized arylsulfatase for the selective assay of sulphate ion . Analytica chimica acta , 84 : 259 – 270 .
  • Daggitt , G.E.G. 1982 . “ Fuel Cells ” . In Science and Engineering Research Council , Oxon : Didcot .
  • Dantelsson , B. , Winquist , F. , Mosbach , K. and Lundstrom , I. 1983 . “ Enzyme transistors ” . In Biotech 83: Proceedings of the International Conference on the Commercial Applications and Implications of Biotechnology Online Publications , 629 – 688 . London : Northwood .
  • Davis , G. , Hill , H.A.O. , Aston , W.J. , Turner , A.P.F. and Higgins , I.J. 1983 . Bio-electrochemicai fuel cell and sensor based on a quinoprotein . Enzyme and Microbial Technology , 5 : 383 – 388 .
  • Davis , J.B. and YaRBOROUgh , H.F. 1962 . Preliminary experiments on a microbial fuel cell . Science , 137 : 615 – 616 .
  • Davis , J.B. and Yarborough , H.F. 1967 . : 848 US Patent 3331
  • Paolaniono , DI. , Arnold , C.L. and Rechnitz , M.A.G.A. 1981 . Serine-selective membrane probe based on immobilised anaerobic bacteria and a potentiometric ammonia gas sensor . Analytica chimica acta , 128 : 121 – 127 .
  • Disalvo , E.A. , Videla , H.A. and Arvia , A.J. 1979 . Kinetic model of a depolarisation-type bioelectrochemical fuel cell . Bioelectrochemisiry and Bioenergetics , 6 : 493 – 508 .
  • Divies , C. 1975 . Remarques sur l’oxidation de 1’ethanol par une ‘electrode microbienne’ de Acinetobacter xylinium . Annals of Microbiology , 126A : 175 – 186 .
  • Drake , R.F. 1968 . Implantable Fuel Cell for an Artificial Heart , US Government PB 177695
  • Durland , P. , David , A. and Thomas , D. 1978 . An enzyme electrode for acetylcholine . Biochimica el biophysica acta , 527 : 277 – 281 .
  • Egorov , A.M. , Recharshky , M.V. and Berezin , I.V. 1981 . Coal-derived liquid fuels provide hydrogen for fuel cell power vehicle propulsion . Chemical Institute , 5 : 20 – 26 .
  • Enfors , S.O. 1981 . Oxygen stabilised enzyme electrode for D-glucose analysis in fermentation broths . Enzyme and Microbial Technology , 3 : 29 – 32 .
  • Farrance , I. and Aldons , J. 1981 . Paracetamol interference with YS1 glucose analyser . Clinical Chemistry , 27 : 782 – 783 .
  • Freiser , H. , ed. 1980 . Ion Selective Electrodes in Analytical Chemistry , Vol. 1 and 2 , New York : Plenum Press .
  • Fricke , G.M. 1980 . Ion selective electrodes . Analytical Chemistry , 52 : 259R – 275R .
  • Fukamachi , K. and Ishirashi , N. 1978 . Chlorpheniramine sensitive electrode . Bunseki Kagaku , 27 : 152 – 155 .
  • Gamman , K. 1977 . Biosensors based on ion-selective electrodes . Analytical Chemistry , 287 : 1 – 9 .
  • Goiha , T. , Hobai , S. and Rozenberg , L. 1978 . Liquid membrane ion selective electrodes for some alkaloids . Farmaco (Bucharest) , 26 : 141 – 147 .
  • Greenfield , P.F. , Krittrell , J.R. and Laurence , R.L. 1975 . Inactivation of immobilised glucose oxidase by hydrogen peroxide . Analytical Chemistry , 1 : 109 – 124 .
  • Guilbault , G.G. 1980 . Enzyme electrode probes . Enzyme and Microbial Technology , 2 : 258 – 264 .
  • Guilbault , G.G. 1982 . Ion selective electrodes applied to enzyme systems . Ion Selective Electrode Reviews , 4 : 187 – 231 .
  • Guilbault , G.G. and Hrabenkova , E. 1970 . An electrode for the determination of amino acids . Analytical Chemistry , 42 : 1779 – 1783 .
  • Guilbault , G.G. and Hrabenkova , E. 1971 . New enzyme electrode probes for D-amino acids and asparagine . Analytica chimica acta , 56 : 285 – 290 .
  • Guilbault , G.G. and Montalvo , J.G. 1970 . An enzyme electrode of the substrate urea . Journal of the American Chemical Society , 92 : 2533 – 2538 .
  • Guilbault , G.G. and Nagy , G. 1973a . Improved urea electrode . Analytical Chemistry , 45 : 417 – 419 .
  • Guilbault , G.G. and Nagy , G. 1973b . Enzyme electrodes for the determination of L-phenylalanine . Analytical Letters , 6 : 301 – 312 .
  • Guilbault , G.G. and Shu , F.R. 1972 . Enzyme electrodes based on the use of a carbon dioxide sensor, urea and L-tyrosine electrodes . Analytical Chemistry , 44 : 2161 – 2166 .
  • Guilbault , G.G. and Tarp , M. 1974 . A specific enzyme electrode for urea . Analytica chimica acta , 73 : 355 – 365 .
  • Hansen , E.H. and Růzuičha , J. 1974 . Enzymatic analysis by means of the air gap electrode, determination of urea in blood . Analytica chimica acta , 72 : 353 – 364 .
  • Herman , H.B. and Rechnitz , G.A. 1975 . Preparation and properties of a carbonate ion selective membrane electrode . Analytica chimica acta , 76 : 155 – 164 .
  • Higgins , I.J. and Hill , H.A.O. 1978 . British Patent 33388/78
  • Higgins, I.J. and Hill, H.A.O. (1979). Microbial generation and interconversions of energy sources. In Proceedings, Society for General Microbiology Symposium on Microbial Technology (AT. Buil, D.C. Ellwood and C Ratiedge, Eds), volume 29, pp. 359–377. Society for General Microbiology, UK.
  • Higgins , I.J. , Best , D.J. and Hammond , R.C. 1980 . New findings in methane-utilising bacteria highlighting their importance in the biosphere and commercial potential . Nature , 286 : 561 – 564 .
  • Higgins , I.J. , Hill , H.A.O. and Plotkin , E.V. 1983 . Sensor for components of a liquid mixture , European Patent Application 0078636.
  • Higgins , I.J. , Hammond , R.C. , Plotkin , E.V. , Hill , H.A.O. , Uosaki , K. , Eddowes , M.J. and Cass , A.E.G. 1980 . “ Electroenzymology and biofuel cells ” . In Hydrocarbons in Biotechnology , Edited by: Harrison , D.E.F. , Higgins , IJ. and Watkinson , R. 181 – 193 . London : Heyden .
  • Hikuma , M. , Fcubo , T. , Yasuda , T. , Karube , I. and Suzuki , S. 1980 . Ammonia electrode with immobilised nitrifying bacteria . Analytical Chemistry , 52 : 1020 – 1024 .
  • Hill , H.A.O. , Walton , W.J. and Higgsns , I.J. 1981 . Electrochemical reduction of dioxygen using a terminal oxidase . FEBS Letters , 126 : 282 – 284 .
  • Hogue , E.R. and Landgraf , W.C. 1981 . Naproxinate ion specific electrode: development and use . Analytical Letters , 14 : 1757 – 1766 .
  • Huff , J.R. and Orth , J.C. 1960 . The USACOM-MERC fuel cell. Electric power generation Program . Advances in Chemistry Series , 90 : 315 – 327 .
  • Hunger , H.F. and Perry , J. 1966 . US Patent 3 , 284 : 239
  • Ionescu , M. , Cilianu , S. , Bunacin , A.A. and Cossofret , V.V. 1981 . Determination of sulpha drugs with ion selective membrane electrodes . Talanta , 28 : 383 – 387 .
  • Janata , J. and Huber , R.J. 1980 . “ Chemically sensitive field effect transistors ” . In Selective Electrodes in Analytical Chemistry , Edited by: Freiser , H. 107 – 174 . New York : Plenum .
  • Jensen , M.A. and Rechnitz , G.A. 1978 . Bacterial membrane electrode for L-cysteine . Analytica chimica acta , 101 : 125 – 130 .
  • Karube , I. , Okada , T. and Suzuki , S. 1982 . A methane gas sensor based on methane oxidising bacteria . Analytica chimica acta , 135 : 61 – 67 .
  • Karube , I. , Matsunaga , T. , Mitsuda , S. and Suzuki , S. 1977 . Microbial Electrode BOD Sensor . Biotechnology and Bioengineering , 19 : 1535 – 1547 .
  • Karube , L , Matsunaga , T. , Teraoka , N. and Suzuki , S. 1980 . Microbioassay of phenylalanine in blood sera with a lactate electrode . Analytica chimica acta , 119 : 271 – 276 .
  • Karube , I. , Sogabe , S. , Matsunaga , T. and Suzuki , S. 1983 . Sulfite ion sensor with use of immobilised organelle . European Journal of Applied Biotechnology , 17 : 216 – 220 .
  • Katz , S.A. and Cowans , J.A. 3965 . Direct potentiometric study of the urea, urease system . Biochimica et biophysica acta , 107 : 605 – 608 .
  • Katz , S.A. and Rechnitz , G.A. 1963 . Direct potentiometric determination of urea after urease hydrolysis . Analytische Chemie , 196 : 248 – 257 .
  • Kobos , R.K. 1980 . “ Potentiometric enzyme methods ” . In Ion-Selective Electrodes in Analytical Chemistry , Edited by: Freiser , H. 1 – 84 . New York : Plenum .
  • Kobos , R.K. and Pyon , H.Y. 1981 . Application of microbial cells as multistep catalysts in potentiometric biosensing electrodes . Biotechnology and Bioengineering , 23 : 627 – 633 .
  • Kobos , R.K. and Ramsay , T.A. 1980 . Enzyme electrode system for oxalate determination utilising oxalate decarboxylase immobilised on a carbon dioxide sensor . Analytica chimica acta , 121 : 111 – 118 .
  • Kobos , R.K. and Rechnitz , G.A. 1977 . Regenerable bacterial membrane electrode for L-aspartate . Analytical Letters , 10 : 757 – 758 .
  • Kobos , R.K. , Rice , D.J. and Flourney , D.S. 1979 . Bacterial membrane electrode for the determination of nitrate . Analytical Chemistry , 57 : 1122 – 1125 .
  • Koryta , J. 1975 . Ion Selective Electrodes , Cambridge University Press .
  • Kuriyama , S. and Rechnitz , G.A. 1981 . Plant tissue based bioselective membrane electrode for glutamate . Analytica chimica acta , 131 : 91 – 96 .
  • Lidh , M. , Lindgren , K. , Carlstrom , A. and Mousson , P. 1982 . Electrochemical interferences with the YSI glucose analyser . Clinical Chemistry , 28 : 726
  • Llenado , R.A. and Rechnitz , G.A. 1973 . Ion electrode based autoanalysis system for enzymes . Analytical Chemistry , 45 : 2165
  • Lobel , E. and Rishpon , J. 1981 . Enzyme electrode for the determination of glucose . Analytical Chemistry , 53 : 51 – 53 .
  • Lowe , C.R. , Goldfinch , M.J. and Lias , R.T. 1983 . “ Some novel biomedical biosensors ” . In Biotech 83: Proceedings of the International Conference on the Commercial Applications of Biotechnology , 633 – 641 . London : Online Publications Northwood .
  • McAuliffe , C.A. 1980 . Hydrogen and Energy , London : Macmillan Press Ltd .
  • McGown , L.B. and Bockris , J.O.M. 1980 . How to Obtain Abundant Clean Energy , New York : Plenum Press .
  • McNeil , R.J. 1969 . The development of a bioeiectrochemical fuel cell for utilisation in space flight . Proceedings of South Dakota Academy of Science , 48 : 174 – 187 .
  • Malmstadt , H.V. and Pardue , H.L. 1961 . Quantitative analysis by an automatic potentiometric reaction rate method. Specific enzymatic determination of glucose . Analytical Chemistry , 33 : 1040 – 1047 .
  • Mascini , M. and Giardini , R. 1980 . Potentiometric determination of proteins with an ammonia sensor . Analylica chimica acta , 114 : 329 – 334 .
  • Matsumoto , K. , Yamata , K. and Osajima , Y. 1981 . Ascorbate electrode for determination of L-ascorbic acid in food . Analytical Chemistry , 53 : 1974 – 1979 .
  • Matsumoto , K. , Seijo , H. , Karube , I. and Suzuki , S. 1980 . Amperometric determination of choline with use of immobilised choline oxidase . Biotechnology and Bio-engineering , 22 : 1071 – 1086 .
  • Matsunaga , T. , Karube , I. and Suzuki , S. 1980 . A specific microbial sensor for formic acid . European Journal of Applied Microbiology and Biotechnology , 10 : 235 – 243 .
  • Mfir , P.L. , Ammann , D. , Mort , W.E. and Simon , W. 1980 . “ Liquid membrane ion selective electrodes and their biomedical applications ” . In Medical and Biological Applications of Electrochemical Devices , Edited by: Koryter , J. 13 – 91 . New York : John Wiley and Sons .
  • Mizuguchi , J. , Suzuki , S. and Takahashi , F. 1966 . Biochemical reaction cell . Bulletin of the Tokyo Institute of Technology , 78 : 27 – 33 .
  • Montalvo , J.G. and Guilbault , G.G. 1969 . Sensitised carbon selective electrode . Analytical Chemistry , 41 : 1897 – 1899 .
  • Moody , J. and Thomas , J.D.R. 1975 . The analytical role of ion selective and gas sensing electrodes in enzymology . Analyst , 100 : 609 – 619 .
  • Mosbach , K. 1983 . “ New biosensor devices ” . In Biotech 83: Proceedings of the International Conference on the Commercial Applications and Implications of Biotechnology , 665 – 678 . London : Online Publications. Northwood .
  • Nagy , G. , Rice , M.E. and Adams , R.N. 1982 . A new type of enzyme electrode: the ascorbic acid eliminator electrode . Life Sciences , 31 : 2611 – 2616 .
  • Nakamura , S. , Hayashi , S. and Koya , K. 1976 . Effect of periodic oxidation on the structure and properties of glucose oxidase . Biochimica et biophysica acta , 445 : 294 – 308 .
  • Nanjo , M. and Guilbault , G.G. 1974 . Enzyme electrode for L-amino acids and glucose . Analytica chimica acta , 73 : 367 – 373 .
  • Nanjo , M. , von Strop , L.M. and Guilbault , G.G. 1973 . Enzyme electrode for glucose, based on an iodine membrane sensor . Analytica chimica acta , 66 : 443 – 455 .
  • Negoiu , D. , Ionescu , M.S. and Cosofret , V.V. 1981 . Determination of novocaine in pharmaceutical preparation with novocaine selective membrane electrodes . Talanta , 28 : 377 – 381 .
  • Newman , D.P. 1976 . US Patent, No. 3979274
  • Okada , T. , Karube , I. and Suzuki , S. 1981 . Microbial sensor system which uses Methylomonas sp. for the determination of methane . European Journal of Applied Microbiology and Biotechnology , 12 : 102 – 106 .
  • Oswald , W. 1984 . Die Wissenschaftliche Elektrochemie der Gergenwart und die Technische der Zukunft, 2 . Elektrochemie , 1 : 122 – 125 .
  • Pan , R.L. , Bhardwaj , R. and Gross , E.L. 1983 . Photochemical energy conversion by a thiazine photosynthetic-photoelectrochemical cell . Journal of Chemical Technology and Biotechnology , 33A : 39 – 48 .
  • Papariello , G.J. , Mukherji , A.K. and Shearer , C.M. 1973 . A penicillin selective enzyme electrode . Analytical Chemistry , 45 : 790 – 792 .
  • Pardue , H.L. 1963 . Automatic amperometric measurement of reaction rates: Enzymatic determination of glucose in serum, plasma and whole blood . Analytical Chemistry , 35 : 1240 – 1243 .
  • Pazur , J.H. , Kleppe , K. and Cepure , A. 1965 . A glycoprotein structure for glucose oxidase from Aspergillus niger . Archives of Biochemistry and Biophysics , 11 ( 35 ) : 3 – 357 .
  • Plotkin , E.V. , Higgins , I.J. and Hill , H.A.O. 1981 . Methanol dehydrogenase bio-electrochemical cell and alcohol detector . Biotechnology Letters , 3 : 187 – 192 .
  • Potter , M.C. 1911 . Electrochemical effects accompanying the decomposition of organic compounds . Proceedings of the University of Durham Philosophical Society , 4 : 260 – 274 .
  • Rechnitz , G.A. 1967 . Ion Selective Electrodes . Chemical and Engineering News June 12th , : 146 – 158 .
  • Rechnitz , G.A. , Kobos , R.K. , Riechel , S.J. and Gebauer , C.R. 1977 . A bioselective membrane electrode prepared with living bacterial cells . Analytica chimica acta , 945 : 357 – 365 .
  • Riechel , T.L. and Rechnitz , G.A. 1978 . Hybrid bacterial and enzyme sensor with NAD response . Journal of Membrane Science , 4 : 243 – 250 .
  • Roller , S.D. , Bennetto , H.P. , Delaney , G.M. , Mason , J.R. , Stirling , J.L. , Thurston , C.F. and White , D.R. Jr . 1983 . “ A biofuel cell for utilisation of lactose wastes ” . In Biotech 83: Proceedings of the International Conference on the Commercial Applications and Implications of Biotechnology , London : Online Publications North-wood .
  • Ross , J.W. , Riseman , J.M. and Krueger , J.A. 1974 . Potentiometric gas sensing electrodes . Pure and Applied Chemistry (IUPAC) , 36 : 473 – 487 .
  • Rossette , J.L. , Froment , B. and Thomas , D. 1979 . Glucose oxidase electrode measurements of glucose in samples exhibiting high variability in oxygen content . Clinica chimica acta , 95 : 249 – 253 .
  • Rourback , G.M. , Scott , W.R. and Canfield , J.H. 1962 . “ Biochemical fuel cells ” . In Proceedings of the American Power Sources Conference, Fort Monmouth, New Jersey May 1962 , volume 16 , 18 – 21 . Fort Monmouth, New Jersey : Committee of the American Power Sources Conference .
  • Satoh , I. , Karube , I. and Suzuki , S. 1976 . Enzyme electrode for sucrose . Biotechnology and Bioengineering , 18 : 269 – 272 .
  • Schenic , J.O. , Miller , E. and Adams , R.N. 1982 . Electrochemical assay for brain ascorbate with ascorbate oxidase . Analytical Chemistry , 54 : 1452 – 1454 .
  • Scott , W.R. and Cohn , E.M. 1962 . Proceedings of the Biochemical Fuel Cell Session, Santa Monica Pic-Bat 209/5 , 9 Philadelphia : Power Information Center .
  • Severinghaus , J.W. 1968 . Measurement of blood glucose, 02 and C02 . Annals of the New York Academy of Sciences , 148 : 115 – 132 .
  • Shichiri , M. , Kawamori , R. , Yamaski , Y. , Hakai , N. and Abe , H. 1982 . Wearable artificial endocrine pancreas with needle type glucose sensor . Lancet , ii : 1129 – 1131 .
  • Sisler , F.D. 1962 . Electrical energy from microbiological processes . Journal of the Washington Academy of Sciences , 52 : 181 – 187 .
  • Sittampalam , G. and Wilson , G.S. 1982 . Amperometric determination of glucose at parts per million levels with immobilised glucose oxidase . Journal of Chemical Education , 59 : 70 – 73 .
  • Suzuki , S. , Karube , I. and Matsunaga , T. 1979 . “ Application of a biochemical fuel cell to wastewaters ” . In Biotechnology in Energy Production and Conservation. Biotechnology and Bioengineering Symposium , volume 8 , 501 – 511 . New York : John Wiley and Sons Inc. .
  • Suzuki , S. , Satoh , I. and Karube , I. 1982 . Recent trends of biosensors in Japan . Applied Biochemistry and Biotechnology , 7 : 147 – 155 .
  • Suzuki , S. , Karube , I. , Matsunaga , T. and Kayano , H. 1980a . Biochemical energy conversion system . Enzyme Engineering , 5 : 143 – 145 .
  • Suzuki , S. , Karube , I. , Matsunaga , T. , Kuriyama , S. , Suzuki , N. , Shirogami , T. and Takamura , Y. 1980b . Biochemical energy conversion using immobilised whole cells of . Clostridium butyricum. Biochimie , 62 : 353 – 358 .
  • Tran , N.D. , Romette , J.L. and Thomas , D. 1983 . An enzyme electrode for specific determination of L-lysine: Real time control sensor . Biotechnology and Bioengineering , 25 : 329 – 340 .
  • Turner , A.P.F. , Higgins , I.J. and Hill , H.A.O. 1982 . “ Biological fuel ceils ” . In Fuel Ceils , Edited by: Daggtt , G.E.G. 107 – 122 . Didcot, Oxon : Science and Engineering Council .
  • Turner , A.P.F. , Ramsay , G. and Higgins , I.J. 1983 . Applications of electron transfer between biological systems and electrodes . Biochemical Society Transactions , 11 : 381 – 384 .
  • Updike , J.W. and Hicks , J.P. 1967 . The enzyme electrode . Nature , 214 : 986 – 988 .
  • Van Hees , W. 1965 . A bacterial fuel cell . Journal of the Electrochemical Society , 112 : 258 – 262 .
  • Vlkduyn , C , van Duken , J.P. and Scheffers , W.A. 1983 . A simple, sensitive and accurate alcohol electrode . Biotechnology and Bioengineering , 21 : 1049 – 1055 .
  • Videla , H.A. and Arvia , A.J. 1975 . The response of a bioelectrochemical cell with Saccharomyces cerevisiae metabolising glucose under fermentation conditions . Biotechnology and Bioengineering , 17 : 1529 – 1543 .
  • Weibel , M.K. and Dodge , C. 1975 . Biochemical fuel cells: demonstration of an obligatory pathway involving an external circuit for the enzymatically catalysed aerobic oxidation of glucose . Archives of Biochemistry and Biophysics , 169 : 146 – 151 .
  • Who . 1980 . WHO Expert Committee Report on Diabetes Mellitus , Geneva : World Health Organization .
  • Wingard, L.B., Katzir, E.K. and Goldstein, L., eds (1981). Analytical Applications of Immobilised Enzymes and Cells. Applied Biochemistry and Bioengineering, volume 3. Academic Press, New York.
  • Wingard , L.B. , Shaw , C.H. and Castner , J.F. 1982 . Bioelectrochemical fuel cells . Enzyme and Microbial Technology 4, , : 137 – 147 .
  • Wollenberger , U. , Scheller , F. and Atrat , P. 1980 . Microbial membrane electrode for the determination of cholesterol . Analytical Letters , 13 : 825 – 836 .
  • Yamamoto , N. and Hiroshi , T. 1981 . Immunoelectrodes . Kaqaku , 36 : 538 – 542 .
  • Young , T.G. 1965 . : 803 British Patent 981.
  • Yudkin , J. 1935 . The reduction potentials of bacterial suspensions . Biochemical Journal , 229 : 1130 – 1135 .
  • Zhukov , A.F. , Ernie , D. , Ammann , D. , Guggi , M. , Pretsch , E. and Simon , W. 1981 . Improved lithium ion selective electrodes based on a lipophilic diamide as neutral carrier . Analytica chimica acta , 131 : 117 – 122 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.