References
- El-Sayed S, Nelson N. Adjuvant and adjunctive chemotherapy in the management of squamous cell carcinoma of the head and neck region: A meta-analysis of prospective and randomized trials. J Clin Oncol 1996; 14: 838–847
- Pignon JP, Bourhis J, Domenge C, Designe L. Chemotherapy added to locoregional treatment for head and neck squamous-cel carcinoma: Three meta-analyses of updated individual data. Lancet 2000; 355: 949–955
- Trotti A. Toxicity in head and neck cancer: A review of trends and issues. Int J Rad Onc Biol Phys 2000; 47: 1–12
- Valdagni R, Liu F-F, Kapp S. Important prognostic factors influencing outcome of combined radiation and hyperthermia. Int J Rad Onc Biol Phys 1988; 15: 959–972
- Valdagni R, Amichetti M. Report of long-term follow-up in a randomized trial comparing radiation therapy and radiation therapy plus hyperthermia to metastatic lymphnodes in stage IV head and neck patients. Int J Rad Onc Biol Phys 1993; 28: 163–169
- Wust P, Seebas M, Nadobny J, Deuflhard P, Monich G, Felix R. Simulation studies promote technological development of radiofrequency phased array hyperthermia. Int J Hyper 1996; 12: 477–498
- Paulides MM, Wielheesen DHM, Van der Zee J, Van Roon GC. Assessment of the local SAR distortion by major anatomical structures in a cylindrical neck phantom. Int J Hyperthermia 2005; 21: 125–140
- Paulides MM, Vossen SHJA, Zwamborn APM, Van Roon GC. Theoretical investigation into the feasibility to deposit RF energy centrally in the head and neck region. Int J Rad Onc Biol Phys 2005; 63: 634–642
- Haveman J, Van Der Zee J, Wondergem J, Hoogeveen JF, Hulshof MC. Effects of hyperthermia on the peripheral nervous system: A review. Int J Hyper 2004; 20: 371–392
- Clemens CHM, Vossen SHJA, Woltering AB, Zwamborn APM. Study of the possible effects on health of the use of portable terminals within the C2000 radio network. TNO-FEL internal report: FEL-02-C152. Reproduction Department of The Netherlands Organisation of Applied Scientific Research (TNO). The Hague, The Netherlands 2003
- Van Leeuwen GMJ, Lagendijk JJW, Van Leersum BJAM, Zwamborn AMP, Hornsleth SN, Kotte ANTJ. Calculation of change in brain temperatures due to exposure to a mobile phone. Phys Med Biol 1999; 44: 2367–2379
- Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. Phys Med Biol 1996; 41: 2271–2293
- Stogryn A. Equations for calculating the dielectric constant of saline water (Correspondence). IEEE Trans Micr Theor Tech. 1971; 19: 733–736
- Lagendijk JJW, Van den Berg PM, Hand JW. ESHO Taskgroup Committe Treatment planning and modelling in hyperthermia, a taskgroup report of the European Society for Hyperthermic Oncology. Tor Vergata, Rome, Italy 1992
- Hornsleth SN. Radiofrequency regional hyperthermia. PhD thesis. Aalborg University. 1996
- de Bruijne M, Samaras T, Bakker JF, Van Roon GC. Effects of waterbolus size, shape and configuration on the SAR distribution pattern of the Lucite cone applicator. Int J Hyper 2006; 22: 15–28
- Jouvie F, Bolomey JC, Gaboriaud G. Discussion of the capabilities of microwave phased arrays for hyperthermia treatment of neck tumours. IEEE Trans Micr Theor Tech 1986; 34: 495–501
- Magin RL, Peterson AF. Noninvasive microwave phased arrays for local hyperthermia: A review. Int J Hyperthermia 1989; 5: 429–450
- Gross EJ, Cetas TC, Stauffer PR, Liu RL, Lumori ML. Experimental assessment of phased-array heating of neck tumours. Int J Hyper 1990; 6: 453–474
- Turner P. Apparatus for creating hyperthermia in tissue. US Patent No. 4,589,423, 1986
- Van Dijk JD, Schneider C, Van Os R, Blank LE, Gonzalez DG. Results of deep body hyperthermia with large waveguide radiators. Adv Exp Med Biol 1990; 267: 315–319
- Seebass M, Beck R, Gellerman J, Nadobny J, Wust P. Electromagnetic phased arrays for regional hyperthermia: Optimal frequency and antenna arrangement. Int J Hyper 2001; 17: 321–336
- Paulsen KD, Geimer S, Tang J, Boyse WE. Optimisation of pelvic heating rate distributions with electromagnetic phased arrays. Int J Hyper 1999; 15: 157–186
- Kroeze H, Van de Kamer JB, De Leeuw AAC, Lagendijk JJW. Regional hyperthermia applicator design using FDTD modelling. Phys Med Biol 2001; 46: 1919–1935
- Crezee J, Kok HP, Wiersma J, Van Stam G, Sijbrands J, Bel A, Van Haaren PMA. Improving locoregional hyperthermia equipment using 3D power control: From AMC-4 to AMC-8. Abstracts ESHO-05. 2005; 14–15