References
- Goldsmith W. The state of head injury biomechanics: past, present, and future: Part 1. Crit Rev Biomed Eng 2001; 29: 441–600
- Kuijpers A H, Claessens M H, Sauren A A. The influence of different boundary conditions on the response of the head to impact: A two-dimensional finite element study. J Neurotrauma 1995; 12: 715–724
- Brands D W, Peters G W, Bovendeerd P H. Design and numerical implementation of a 3-D non-linear viscoelastic constitutive model for brain tissue during impact. J Biomech. 2004; 37: 127–134
- Kyriacou S K, Mohamed A, Miller K, Neff S. Brain mechanics for neurosurgery: Modeling issues. Biomech Model Mechanobiol 2002; 1: 151–164
- Miller K, Chinzei K. Constitutive modelling of brain tissue: Experiment and theory. J Biomech 1997; 30: 1115–1121
- Miller K. Constitutive model of brain tissue suitable for finite element analysis of surgical procedures. J Biomech 1999; 32: 531–537
- Miller K. Non-linear computer simulation of brain deformation. Biomed Sci Instrum 2001; 37: 179–184
- Miller K, Chinzei K, Orssengo G, Bednarz P. Mechanical properties of brain tissue in-vivo: experiment and computer simulation. J Biomech 2000; 33: 1369–1376
- Bilston L E, Liu Z, Phan-Thien N. Linear viscoelastic properties of bovine brain tissue in shear. Biorheology 1997; 34: 377–385
- Schettini A, Walsh E K. Brain tissue elastic behavior and experimental brain compression. Am J Physiol 1988; 255: 799–805
- Belshi R, Pontvert D, Rosenwald J C, Gaboriaud G. Automatic three-dimensional expansion of structures applied to determination of the clinical target volume in conformal radiotherapy. Int J Radiat Oncol Biol Phys 1997; 37: 689–696
- Donnelly B R, Medige J. Shear properties of human brain tissue. J Biomech Eng 1997; 119: 423–432
- Secomb T W, El-Kareh A W. A theoretical model for the elastic properties of very soft tissues. Biorheology 2001; 38: 305–317
- Gavin C M, Smith C J, Emsley H C, Hughes D G, Turnbull I W, Vail A, Tyrrell P J. Reliability of a semi-automated technique of cerebral infarct volume measurement with CT. Cerebrovasc Dis 2004; 18: 220–226
- Monsky W L, Raptopoulos V, Keogan M T, Doty D, Kamel I, Yam C S, Ransil B J. Reproducibility of linear tumor measurements using PACS: Comparison of caliper method with edge-tracing method. Eur Radiol 2004; 14: 519–525
- Miller K. Non-linear computer stimulation of brain deformation. Biomed Sci Instrum 2001; 3: 179–184
- Gefen A, Margulies S S. Are in vivo and in situ brain tissues mechanically similar?. J Biomech 2004; 37: 1339–1352
- Gefen A, Gefen N, Zhu Q, Raghupati R, Margulies S S. Age dependent changes in material properties of the brain and braincase of the rat. J Neurotrauma 2003; 20: 1163–1177
- Prange M T, Margulies S S. Regional, directional, and age-dependent properties of the brain undergoing large deformation. J Biomech Eng 2002; 124: 244–252