References
- Boyd R, Ada L. Physiotherapy management of spasticity. In: Barnes M, Johnson G, editors. Upper motor neurone syndrome and spasticity. Clinical Management and Neurophysiology. Cambridge: Cambridge University Press; 2001. p. 96–121.
- Lance J. The control of muscle tone, reflexes and movement: Robert Wartenberg lecture. Neurology. 1980;30:1301–13. doi:10.1212/WNL.30.12.1303.
- Pandyan A, Gregoric M, Barnes M, Wood D, Van Wijck F, Burridge J, Hermens H, Spasticity: JG. Clinical perceptions, neurological realities and meaningful measurement. Disabil Rehabil. 2005;27(1/2):2–6. doi:10.1080/09638280400014576.
- Burridge J, Wood D, Hermens H, Voerman G, Johnson G, Van Wijik F, Platz T, Gregoric M, Hitchcock R, Pandyan A. Theoretical and methodological considerations in the measurement of spasticity. Disabil Rehabil. 2005;27(1/2):69–80. doi:10.1080/09638280400014592.
- Barnes M. An overview of the clinical measurement of spasticity. In: Barnes M, Johnson G, editors. Upper motor neurone syndrome and spasticity: clinical management and neurophysiology. Cambridge: Cambridge University Press; 2001. p. 1–11.
- Tardieu G, Rondont O, Mensch J, Dalloz J-C, Monfraix C, Tabary J-C. Responses electromyographiques a l’etirement musculaire chez l’homme normal. Rev Neurol. 1957;97:60–61.
- Gracies J-M. Reliability of the Tardieu Scale. Pers Comm. 2001.
- Gracies J-M. Evaluation de la spasticite apport de l’echelle de Tardieu. Motricite Cerebrale. 2001;22:1–16.
- Ashworth B. Preliminary trial of carisprodal in multiple sclerosis. Practitioner. 1964;192:54–542.
- Bohannon R, Smith M. Interrater reliability of a modified Ashworth scale of muscle spasticity. Phys Ther. 1987;67:206–07. doi:10.1093/ptj/67.2.206.
- Ansari N, Naghdi S, Moammeri H, Ashworth JS. Scales are unreliable for the assessment of muscle spasticity. Physiother Theory Pract. 2006;22(3):119–25. doi:10.1080/09593980600724188.
- Mehrholz J, Major Y, Meissner D. The influence of contractures and variation in measurement stretching velocity on the reliability of the modified Ashworth scale in patients with severe brain injury. Clin Rehabil. 2005;19:63–72. doi:10.1191/0269215505cr824oa.
- Ghotbi N, Ansari N, Naghdi S, Hasson S, Jamshidpour B, Amiri S. Inter-rater reliability of modified modified Ashworth scale in assessing lower limb muscle spasticity. Brain Injury. 2009;23(10):815–19. doi:10.1080/02699050903200548.
- Ghotbi N, Ansari N, Naghdi S, Hasson S. Measurement of lower limb muscle spasticity: intra-rater reliability of modified modified Ashworth scale. J Rehabil Res Dev. 2011;48(1):83–88. doi:10.1682/JRRD.2010.02.0020.
- Held J, Reeducation P-DE. Mortrice des affections Neurologiques. In: Held J, Pierrot-Desilligny E, editors. J.B. Balliere et fils. Paris: Bailliere; 1969. p. 31–42.
- Love S, Gibson N, Smith N, Bear N, Blair E. Interobserver reliability of the Australia Spasticity Assessment (ASAS). Dev Med Child Neurol. 2016;58(suppl.2):18–24. doi:10.1111/dmcn.13000.
- Gracies J-M, Marosszeky J, Renton R, Sandaman J, Gandevia S, Burke D. Short term effects of dynamic lycra splints on upper limb in hemiplegia patients. Arch Phys Med Rehabil. 2000;81:1547–55. doi:10.1053/apmr.2000.16346.
- Gracies J-M, Burke K, Clegg N, Browne R, Rushing C, Fehlings D, Matthews D, Tilton A, Delgado M. Reliability of the Tardieu Scale for assessing spasticity in children with cerebral palsy. Arch Phys Med Rehabil. 2010;91:421–28. doi:10.1016/j.apmr.2009.11.017.
- Boyd R, Graham K. Objective measurement of clinical findings in the use of botulinum toxin type A for the management of children with cerebral palsy. Eur J Neurol. 1999;6(suppl4):S23–S35. doi:10.1111/ene.1999.6.issue-S4.
- Ben-Shabat E, Palit M, Fini N, Brook C, Winter A, Holland A. Intra and interrater reliability of modified Tardieu Scale for the assessment of lower limb spasticity in adults with neurologic injuries. Arch Phys Med Rehabil. 2013;94:2494–501. doi:10.1016/j.apmr.2013.06.026.
- Vattanasilp W, Ada L, Crosbie J. Contribution of thixotrophy, spasticity and contracture to ankle stiffness after stroke. J Neurol Neurosurg Psychiatry. 2000;69:34–39. doi:10.1136/jnnp.69.1.34.
- Hagbarth K-E, Hagglund J, Nordin M. Thixotrophic behaviour of human finger muscles with accompanying changes in spindle and reflex responses to stretch. J Physiol. 1985;378:323–42. doi:10.1113/jphysiol.1985.sp015860.
- Ansari N, Naghdi S, Hasson S, Azarsa M, Azaria S. The modified Tardieu scale for the measurement of elbow flexor spasticity in adult patients with hemiplegia. Brain Injury. 2008;22(13–14):1007–12. doi:10.1080/02699050802530557.
- Ansari N, Naghdi S, Hasson S, Rastgoo M, Amini M, Forogh B. Clinical assessment of ankle pantarflexor spasticity in adult patients after stroke: inter and intra rater reliability of the modified Tardieu Scale. Brain Injury. 2013;27(5):605–12. doi:10.3109/02699052.2012.750744.
- Naghdi S, Ansari N, Chorbani-Rad S, Sahraian M. Intra rater reliability of the modified Tardieu scale in patients with multiple sclerosis. Neurol Sci. 2017;38(10):93–99. doi:10.1007/s10072-016-2714-7.
- Naghdi S, Ansari N, Abolhasani H, Mansouri K, Chotbi N, Hasson S. Electrophysiological evaluation of the modified Tardieu scale in assessing post-stroke wrist flexor spasticity. NeuroRehabil. 2014;34(1):177–84.
- Gibson N, Love S, Blair E, Watson L. The cerebral palsy description form and Australian spasticity assessment scale. CD. Perth, Australia: Physiotherapy Department, Princess Margaret Hospital; 2014.
- Haugh A, Pandyan A, Johnson G. A systematic review of the Tardieu Scale for the measurement of spasticity. Disabil Rehabil. 2006;28(15):899–907. doi:10.1080/09638280500404305.