215
Views
7
CrossRef citations to date
0
Altmetric
Articles

Quantification of energy expenditure during daily living activities after stroke by multi-sensor

ORCID Icon, , , , ORCID Icon & ORCID Icon
Pages 1341-1346 | Received 13 Nov 2018, Accepted 06 Jul 2019, Published online: 16 Jul 2019

References

  • Benjamin EJ, Blaha MJ, Chiuve SE, Cushman M, Das SR, Deo R, Floyd J, Fornage M, Gillespie C, Isasi CR, et al. Heart disease and stroke statistics-2017 update: a report from the American Heart Association. Circulation. 2017 Mar 7;135(10):e146–603. doi:10.1161/CIRCULATIONAHA.117.027305.
  • Billinger SA, Arena R, Bernhardt J, Eng JJ, Franklin BA, Johnson CM, MacKay-Lyons M, Macko RF, Mead GE, Roth EJ, et al. Physical activity and exercise recommendations for stroke survivors: a statement for healthcare professionals from the American Heart Association/American Stroke Association. Stroke. 2014 Aug 1;45(8):2532–53. doi:10.1161/STROKEAHA.114.004313.
  • Physical Activity Guidelines Advisory Committee Report, 2008. Washington, DC: US Dept of Health and Human Services; 2008. http://www.health.gov/paguidelines/report/.
  • Fulk GD, Combs SA, Danks KA, Nirider CD, Raja B, Reisman DS. Accuracy of 2 activity monitors in detecting steps in people with stroke and traumatic brain injury. Phys Ther. 2014 Feb; 94(2): 222–29. doi:10.2522/ptj.20120525.
  • Klassen TD, Simpson LA, Lim SB, Louie DR, Parappilly B, Sakakibara BM, Zbogar D, Eng JJ. “Stepping Up” activity poststroke: ankle-positioned accelerometer can accurately record steps during slow walking. Phys Ther. 2016;96(3):355–60. doi:10.2522/ptj.20150012.
  • Berntsen S, Hageberg R, Aandstad A, Mowinckel P, Anderssen SA, Carlsen K-H, Andersen LB. Validity of physical activity monitors in adults participating in free-living activities. Br J Sports Med. 2010 Jul;44(9):657–64. doi:10.1136/bjsm.2008.049783.
  • Resnick B, Michael K, Shaughnessy M, Nahm ES, Kobunek S, Sorkin J, Orwig D, Goldberg A, Macko RF. Inflated perceptions of physical activity after stroke: pairing self-report with physiologic measures. J Phys Act Health. 2008 Mar;5(2):308–18. doi:10.1123/jpah.5.2.308.
  • Sirichana W, Dolezal BA, Neufeld EV, Wang X, Cooper CB. Wrist-worn triaxial accelerometry predicts the energy expenditure of non-vigorous daily physical activities. J Sci Med Sport. 2017 Aug; 20(8): 761–65. doi:10.1016/j.jsams.2017.01.233.
  • Moufawad El Achkar C, Lenoble-Hoskovec C, Paraschiv-Ionescu A, Major K, Büla C, Aminian K. Physical behavior in older persons during daily life: insights from instrumented shoes. Sensors. 2016 Aug 3;16(8):1225. doi:10.3390/s16122100.
  • Crouter SE, Churilla JR, Jr DRB. Estimating energy expenditure using accelerometers. Eur J Appl Physiol. 2006 Dec 1;98(6):601–12. doi:10.1007/s00421-006-0307-5.
  • Gebruers N, Vanroy C, Truijen S, Engelborghs S, De Deyn PP. Monitoring of physical activity after stroke: a systematic review of accelerometry-based measures. Arch Phys Med Rehabil. 2010 Feb 1;91(2):288–97. doi:10.1016/j.apmr.2009.10.025.
  • Faria GS, Polese JC, Ribeiro-Samora GA, Scianni AA, Faria CDCM, Teixeira-Salmela LF. Validity of the accelerometer and smartphone application in estimating energy expenditure in individuals with chronic stroke. Braz J Phys Ther. (2019);23(3), 236–243. https://linkinghub.elsevier.com/retrieve/pii/S1413355518300078
  • Mandigout S, Lacroix J, Ferry B, Vuillerme N, Compagnat M, Daviet J-C. Can energy expenditure be accurately assessed using accelerometry-based wearable motion detectors for physical activity monitoring in post-stroke patients in the subacute phase? Eur J Prev Cardiol. 2017 Dec; 24(18): 2009–16. doi:10.1177/2047487317738593.
  • Brazeau A-S, Karelis AD, Mignault D, Lacroix M-J, Prud’homme D, Rabasa-Lhoret R. Accuracy of the SenseWear ArmbandTM during Ergocycling. Int J Sports Med. 2011 Oct; 32(10): 761–64. doi:10.1055/s-0031-1275302.
  • Drenowatz C, Eisenmann JC. Validation of the SenseWear Armband at high intensity exercise. Eur J Appl Physiol. 2011 May; 111(5): 883–87. doi:10.1007/s00421-010-1695-0.
  • Fruin ML, Rankin JW. Validity of a multi-sensor armband in estimating rest and exercise energy expenditure. Med Sci Sports Exerc. 2004 Jun; 36(6): 1063–69. doi:10.1249/01.MSS.0000128144.91337.38.
  • Colbert LH, Matthews CE, Havighurst TC, KIM K, Schoeller DA. Comparative validity of physical activity measures in older adults. Med Sci Sports Exerc. 2011 May; 43(5): 867–76. doi:10.1249/MSS.0b013e3181edefaa.
  • Moore SA, Hallsworth K, Bluck LJC, Ford GA, Rochester L, Trenell MI. Measuring energy expenditure after stroke validation of a portable device. Stroke. 2012 Jan 6;43(6):1660–62. doi:10.1161/STROKEAHA.111.646257.
  • Demeurisse G, Demol O, Robaye E. Motor evaluation in vascular hemiplegia. Eur Neurol. 1980;19(6):382–89. doi:10.1159/000115178.
  • Collin C, Wade D. Assessing motor impairment after stroke: a pilot reliability study. J Neurol Neurosurg Psychiatry. 1990 Jul; 53(7): 576–79. doi:10.1136/jnnp.53.7.576.
  • Bohannon RW, Smith MB. Interrater reliability of a modified Ashworth scale of muscle spasticity. Phys Ther. 1987 Feb; 67(2): 206–07. doi:10.1093/ptj/67.2.238.
  • Mahoney FI, Barthel DW. Functional evaluation: the Barthel Index. Md State Med J. 1965;14:61–65.
  • Duffield R, Dawson B, Pinnington HC, Wong P. Accuracy and reliability of a Cosmed K4b2 portable gas analysis system. J Sci Med Sport Sports Med Aust. 2004 Mar; 7(1): 11–22. doi:10.1016/S1440-2440(04)80039-2.
  • Vogler AJ, Rice AJ, Gore CJ. Validity and reliability of the Cortex MetaMax3B portable metabolic system. J Sports Sci. 2010 May; 28(7): 733–42. doi:10.1080/02640410903582776.
  • Stookey AD, McCusker MG, Sorkin JD, Katzel LI, Shaughnessy M, Macko RF, Ivey FM. Test and re-test reliability of portable monitoring after disabling stroke. Neurorehabil Neural Repair. 2013;27:872–77.
  • Cavalheri V, Donária L, Ferreira T, Finatti M, Camillo CA, Cipulo Ramos EM, Pitta F. Energy expenditure during daily activities as measured by two motion sensors in patients with COPD. Respir Med. 2011 Jun;105(6):922–29. doi:10.1016/j.rmed.2011.03.020.
  • Manns PJ, Haennel RG. SenseWear armband and stroke: validity of energy expenditure and step count measurement during walking. Stroke Res Treat. 2012;2012:247165.
  • McArdle WD, Katch FI, Katch VL. Exercise physiology: energy, nutrition and human performance. 4th ed. Baltimore: Lippincott Williams and Wilkins; 1996. p. 900.
  • Hinkle DE, Wiersma W, Jurs SG. Applied statistics for the behavioral sciences. 5th ed. Boston: Houghton Mifflin; 2002. p. 756 p.
  • Lee J-M, Kim Y, Welk GJ. Validity of consumer-based physical activity monitors. Med Sci Sports Exerc. 2014 Sep; 46(9): 1840–48. doi:10.1249/MSS.0000000000000287.
  • Chowdhury EA, Western MJ, Nightingale TE, et al. Assessment of laboratory and daily energy expenditure estimates from consumer multi-sensor physical activity monitors. PLoS One. [Internet]. 2017; 12. http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5325221/ doi:10.1371/journal.pone.0171720
  • Lu M-J, Zhong W-H, Liu Y-X, Miao H-Z, Li Y-C, Ji M-H. Sample size for assessing agreement between two methods of measurement by bland-altman method. Int J Biostat. 2016 Nov 1;12:2. doi:10.1515/ijb-2015-0039.
  • Ainsworth BE, Haskell WL, Herrmann SD, Meckes N, Bassett DR, Tudor-Locke C, Greer JL, Vezina J, Whitt-Glover MC, et al. 2011 compendium of physical activities: a second update of codes and MET values. Med Sci Sports Exerc. 2011 Aug;43(8):1575–81. doi:10.1249/MSS.0b013e3181edefaa.
  • WHO | physical activity [Internet]. WHO. http://www.who.int/topics/physical_activity/en/.
  • English C, Manns PJ, Tucak C, Bernhardt J. Physical activity and sedentary behaviors in people with stroke living in the community: a systematic review. Phys Ther. 2014 Feb 1;94(2):185–96. doi:10.2522/ptj.20130175.
  • Roos MA, Rudolph KS, Reisman DS. the structure of walking activity in people after stroke compared with older adults without disability: a cross-sectional study. Phys Ther. 2012 Sep; 92(9): 1141–47. doi:10.2522/ptj.20110009.
  • Bowden MG, Balasubramanian CK, Behrman AL, Kautz SA. Validation of a speed-based classification system using quantitative measures of walking performance post-stroke. Neurorehabil Neural Repair. 2008;22(6):672–75. doi:10.1177/1545968308318837.
  • Jakicic JM, Marcus M, Gallagher KI, Randall C, Thomas E, Goss FL, Robertson R. Evaluation of the SenseWear Pro Armband to assess energy expenditure during exercise. Med Sci Sports Exerc. 2004 May;36(5):897–904. doi:10.1249/01.MSS.0000126805.32659.43.
  • Casiraghi F, Lertwattanarak R, Luzi L, Chavez AO, Davalli AM, Naegelin T, Comuzzie AG, Frost P, Musi N, Folli F. Energy expenditure evaluation in humans and non-human primates by SenseWear Armband. Validation of energy expenditure evaluation by SenseWear Armband by direct comparison with indirect calorimetry. PLoS One. 2013 Sep 19;8(9):e73651–e73651. doi:10.1371/journal.pone.0073651.
  • Hill K, Dolmage TE, Woon L, Goldstein R, Brooks D. Measurement properties of the SenseWear armband in adults with chronic obstructive pulmonary disease. Thorax. 2010 Jun 1;65(6):486–91. doi:10.1136/thx.2009.128702.
  • Koehler K, Abel T, Wallmann-Sperlich B, Dreuscher A, Anneken V. Energy expenditure in adolescents with cerebral palsy: comparison of the SenseWear Armband and indirect calorimetry. J Phys Act Health. 2015 Apr; 12(4): 540–45. doi:10.1123/jpah.2013-0294.
  • Hiremath SV, Ding D, Farringdon J, Cooper RA. Predicting energy expenditure of manual wheelchair users with spinal cord injury using a multisensor-based activity monitor. Arch Phys Med Rehabil. 2012 Nov; 93(11): 1937–43. doi:10.1016/j.apmr.2012.05.004.
  • Reece JD, Barry V, Fuller DK, Caputo J. Validation of the SenseWear Armband as a measure of sedentary behavior and light activity. J Phys Act Health. 2015 Sep; 12(9): 1229–37. doi:10.1123/jpah.2014-0136.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.