REFERENCES
- Doane M G. Blinking and the mechanics of the lacrimal drainage system. Ophthalmology 1981; 88(8)844–851
- Jones L T. Anatomy of the tear system. Int Ophthalmol Clin. 1973; 13(1)3–22
- Maurice D M. The dynamics and drainage of tears. Int Ophthalmol Clin. 1973; 13(1)103–116
- Zhu H, Chauhan A. mathematical model for tear drainage through the canaliculi. Curr Eye Res. 2005; 30(8)621–630
- Kakizaki H, Zako M, Miyaishi O, Nakano T, Asamoto K, Iwaki M. The lacrimal canaliculus and sac bordered by the Horner's muscle form the functional lacrimal drainage system. Ophthalmology 2005; 112(4)710–716
- Paulsen F P, Thale A B, Hallmann U J, Schaudig U, Tillmann B N. The cavernous body of the human efferent tear ducts: function in tear outflow mechanism. Invest Ophthalmol Vis Sci. 2000; 41(5)965–970
- Rosengren B. On lacrimal drainage. Ophthalmologica 1972; 164(6)409–421
- Wilson G, Merrill R. The lacrimal drainage system: pressure changes in the canaliculus. Am J Optom Physiol Opt. 1976; 53(2)55–59
- Sahlin S, Laurell C G, Chen E, Philipson B. Lacrimal drainage capacity, age and blink rate. Orbit. 1998; 17(3)155–159
- Becker B B. Tricompartment model of the lacrimal pump mechanism. Ophthalmology. 1992; 99(7)1139–1145
- http://rsb.info.nih.gov/ij/ Image J software. Available at(last accessed June 2007)
- Menard K P. Dynamic Mechanical Analysis: A Practical Introduction. CRC Press LLC, Boca Raton 1999
- Jones D S. Dynamic mechanical analysis of polymeric systems of pharmaceutical and biomedical significance. Int J Pharm. 1999; 179(2)167–178
- Schlesing W, Buhk M, Osterhold M. Dynamic mechanical analysis in coatings industry. Prog Organic Coatings. 2004; 49: 197–20
- Yamashita J, Furman B R, Rawls H R, Wang X, Agrawal C M. The use of dynamic mechanical analysis to assess the viscoelastic properties of human cortical bone. J Biomed Mater Res. 2001; 58(1)47–53
- Crisp E. The growth and maturity of animals. Veterinary Review and Stockowners Journal. 1865
- Blondel W C, Didelon J, Maurice G, Carteaux J P, Wang X, Stoltz J F. Investigation of 3-D mechanical properties of blood vessels using a new in vitro tests system: results on sheep common carotid arteries. IEEE Trans Biomed Eng. 2001; 48(4)442–451
- Shinohara H, Kominami R, Yasutaka S, Taniguchi Y. The anatomy of the lacrimal portion of the orbicularis oculi muscle (tensor tarsi or Horner's muscle). Okajimas Folia Anat Jpn. 2001; 77(6)225–232
- Stevens J R, Livermore A, Jr. Eye blinking and rapid eye movement: pulsed photic stimulation of the brain. Exp Neurol. 1978; 60(3)541–556
- Wang H, Prendiville P L, McDonnell P J, Chang W V. An ultrasonic technique for the measurement of the elastic moduli of human cornea. J Biomech. 1996; 29(12)1633–1636
- Shadwick R E. Mechanical design in arteries. Exp Biol. 1999; 202: 3305–3313, (Pt 23)