References
- Levatin P. Pupillary escape in disease of the retina or optic nerve. Arch Ophthalmol 1959;62:768–779.
- Levatin P, Prasloski PF, Collen MF. The swinging flashlight test in multiphasic screening for eye disease. Can J Ophthalmol 1973;8:356–360.
- Thompson HS, Corbett JJ, Cox TA. How to measure the relative afferent pupillary defect. Surv Ophthalmol 1981;26:39–42.
- Kawasaki A, Moore P, Kardon RH. Variability of the relative afferent pupillary defect. Am J Ophthalmol 1995;120:622–633.
- Lagreze WD, Kardon RH. Correlation of relative afferent pupillary defect and estimated retinal ganglion cell loss. Graefes Arch Clin Exp Ophthalmol 1998;236:401–404.
- Lankaranian D, Altangerel U, Spaeth GL, Leavitt JA, Steinmann WC. The usefulness of a new method of testing for a relative afferent pupillary defect in patients with ocular hypertension and glaucoma. Trans Am Ophthalmol Soc 2005;103:200–207; discussion 207–208.
- Wang JC, Gazzard G, Foster PJ, Devereux JG, Oen FT, Chew PT, et al. Interocular asymmetry of visual field defects in primary open angle glaucoma and primary angle-closure glaucoma. Eye (Lond) 2004;18:365–368.
- Chang DS, Xu L, Boland MV, Friedman DS. Accuracy of pupil assessment for the detection of glaucoma: a systematic review and meta-analysis. Ophthalmology 2013;120:2217–2225.
- Chang DS, Arora KS, Boland MV, Supakontanasan W, Friedman DS. Development and validation of an associative model for the detection of glaucoma using pupillography. Am J Ophthalmol 2013;156:1285–1296 e1282.
- Tatham AJ, Meira-Freitas D, Weinreb RN, Zangwill LM, Medeiros FA. Detecting glaucoma using automated pupillography. Ophthalmology 2014;121:1185–1193.
- Ozeki N, Yuki K, Shiba D, Tsubota K. Pupillographic evaluation of relative afferent pupillary defect in glaucoma patients. Br J Ophthalmol 2013;97:1538–1542.
- Tatham AJ, Meira-Freitas D, Weinreb RN, Marvasti AH, Zangwill LM, Medeiros FA. Estimation of retinal ganglion cell loss in glaucomatous eyes with a relative afferent pupillary defect. Invest Ophthalmol Vis Sci 2014;55:513–522.
- Pepe MS. Three approaches to regression analysis of receiver operating characteristic curves for continuous test results. Biometrics 1998;54:124–135.
- Pepe MS. An interpretation for the ROC curve and inference using GLM procedures. Biometrics 2000;56:352–359.
- Pepe MS. The Statistical Evaluation of Medical Tests for Classification and Prediction. Oxford, UK: Oxford University Press; 2003:130–67.
- Sihota R, Saxena R, Agarwal HC. Entropion uveae: early sphincter atrophy, signposting primary angle closure glaucoma? Eur J Ophthalmol 2004;14:290–297.