References
- Rahman I, Carley F, Hillarby C, Brahma A, Tullo AB. Penetrating keratoplasty: indications, outcomes, and complications. Eye (Lond). 2009;23:1288–94. doi:https://doi.org/10.1038/eye.2008.305.
- Terry MA, Straiko MD, Veldman PB, Talajic JC, VanZyl C, Sales CS, Mayko ZM. Standardized DMEK technique: reducing complications using prestripped tissue, novel glass injector, and sulfur hexafluoride (SF6) gas. Cornea. 2015;34:845–52. doi:https://doi.org/10.1097/ICO.0000000000000479.
- Melles GR, San Ong T, Ververs B, van der Wees J. Descemet membrane endothelial keratoplasty (DMEK). Cornea. 2006;25:987–90. doi:https://doi.org/10.1097/01.ico.0000248385.16896.34.
- Busin M, Bhatt PR, Scorcia V. A modified technique for Descemet membrane stripping automated endothelial keratoplasty to minimize endothelial cell loss. Arch Ophthalmol. 2008;126:1133–37.
- Busin M, Leon P, Scorcia V, Ponzin D. Contact lens-assisted pull-through technique for delivery of tri-folded (Endothelium in) DMEK grafts minimizes surgical time and cell loss. Ophthalmology. 2016;123:476–83. doi:https://doi.org/10.1016/j.ophtha.2015.10.050.
- Dapena I, Ham L, Melles GR. Endothelial keratoplasty: DSEK/DSAEK or DMEK the thinner the better? Curr Opin Ophthalmol. 2009;20:299–307. doi:https://doi.org/10.1097/ICU.0b013e32832b8d18.
- Koenig SB, Covert DJ, Dupps WJ Jr., Meisler DM. Visual acuity, refractive error, and endothelial cell density six months after Descemet stripping and automated endothelial keratoplasty (DSAEK). Cornea. 2007;26:670–74. doi:https://doi.org/10.1097/ICO.0b013e3180544902.
- Bahar I, Kaiserman I, Levinger E, Sansanayudh W, Slomovic AR, Rootman DS. Retrospective contralateral study comparing descemet stripping automated endothelial keratoplasty with penetrating keratoplasty. Cornea. 2009;28:485–88. doi:https://doi.org/10.1097/ICO.0b013e3181901df4.
- Bahar I, Kaiserman I, Sansanayudh W, Levinger E, Rootman DS. Busin guide vs forceps for the insertion of the donor lenticule in Descemet stripping automated endothelial keratoplasty. Am J Ophthalmol. 2009;147:220–26. doi:https://doi.org/10.1016/j.ajo.2008.08.029.
- Price MO, Giebel AW, Fairchild KM, Price FW. Descemet’s membrane endothelial keratoplasty: prospective multicenter study of visual and refractive outcomes and endothelial survival. Ophthalmology. 2009;116:2361–68. doi:https://doi.org/10.1016/j.ophtha.2009.07.010.
- Parekh M, Ruzza A, Romano V, Favaro E, Baruzzo M, Salvalaio G, Grassetto A, Ferrari S, Ponzin D. Descemet membrane endothelial keratoplasty learning curve for graft preparation in an eye bank using 645 donor corneas. Cornea. 2018;37:767–71. doi:https://doi.org/10.1097/ICO.0000000000001553.
- Parekh M, Leon P, Ruzza A, Borroni D, Ferrari S, Ponzin D, Romano V. Graft detachment and rebubbling rate in Descemet membrane endothelial keratoplasty. Surv Ophthalmol. 2018;63:245–50. doi:https://doi.org/10.1016/j.survophthal.2017.07.003.
- Mehta JS, Por YM, Poh R, Beuerman RW, Tan D. Comparison of donor insertion techniques for Descemet stripping automated endothelial keratoplasty. Arch Ophthalmol. 2008;126:1383–88. doi:https://doi.org/10.1001/archopht.126.10.1383.
- Price MO, Price FW. Endothelial cell loss after Descemet stripping with endothelial keratoplasty: influencing factors and 2-year trend. Ophthalmology. 2008;115:857–65. doi:https://doi.org/10.1016/j.ophtha.2007.06.033.
- Cheng YYY, Schouten JSAG, Tahzib NG, Wijdh RJ, Pels E, van Cleynenbreugel H, Eggink CA, Rijneveld WJ, Nuijts RMMA. Efficacy and safety of femtosecond laser-assisted corneal endothelial keratoplasty: a randomized multicenter clinical trial. Transplantation. 2009;88:1294–302. doi:https://doi.org/10.1097/TP.0b013e3181bc419c.
- Ide T, Yoo SH, Goldman JM, Perez V, O’brien TP. Descemet-stripping automated endothelial keratoplasty: effect of inserting forceps on DSAEK donor tissue viability by using an in vitro delivery model and vital dye assay. Cornea. 2007;26:1079–81. doi:https://doi.org/10.1097/ICO.0b013e318142bdde.
- Khan SN, Shiakolas PS, Mootha VV. Descemet’s stripping automated endothelial keratoplastytissue insertion devices. J Ophthalmic Vis Res. 2015;10:461–68. doi:https://doi.org/10.4103/2008-322X.176899.
- Busin M. DSAEK for the treatment of endothelial disease: results in the initial 100 cases. Klin Monbl Augenheilkd. 2009;226:757–60. doi:https://doi.org/10.1055/s-0028-1109545.
- Ang M, Mehta JS, Anshu A, Wong HK, Htoon HM, Tan D. Endothelial cell counts after Descemet’s stripping automated endothelial keratoplasty versus penetrating keratoplasty in Asian eyes. Clin Ophthalmol. 2012;6:537–44. doi:https://doi.org/10.2147/OPTH.S26343.
- Gangwani V, Obi A, Hollick EJ. A prospective study comparing EndoGlide and Busin glide insertion techniques in descemet stripping endothelial keratoplasty. Am J Ophthalmol. 2012;153:38–43. doi:https://doi.org/10.1016/j.ajo.2011.06.013.
- Tan D, Ang M, Arundhati A, Khor WB. Development of selective lamellar keratoplasty within an Asian corneal transplant program: the Singapore corneal transplant study (an American ophthalmological society thesis). Trans Am Ophthalmol Soc. 2015;113.
- Parekh M, Ruzza A, Steger B, Willoughby CE, Ferrari S, Ponzin D, Kaye SB, Romano V. Avoiding complications associated with preloaded ultrathin Descemet stripping automated endothelial keratoplasty. Cornea. 2017;36:e12-e-13. doi:https://doi.org/10.1097/ICO.0000000000001156.
- Ruzza A, Parekh M, Ferrari S, Salvalaio G, Nahum Y, Bovone C, Ponzin D, Busin M. Preloaded donor corneal lenticules in a new validated 3D printed smart storage glide for Descemet stripping automated endothelial keratoplasty. Br J Ophthalmol. 2015;99:1388–95. doi:https://doi.org/10.1136/bjophthalmol-2014-306510.
- Parekh M, Ruzza A, Steger B, Willoughby CE, Rehman S, Ferrari S, Ponzin D, Kaye SB, Romano V. Cross-country transportation efficacy and clinical outcomes of preloaded large-diameter ultrathin descemet stripping automated endothelial keratoplasty grafts. Cornea. 2019;38:30–34. doi:https://doi.org/10.1097/ICO.0000000000001777.
- Khor WB, Mehta JS, Tan DT. Descemet stripping automated endothelial keratoplasty with a graft insertion device: surgical technique and early clinical results. Am J Ophthalmol. 2011;151:223–32. doi:https://doi.org/10.1016/j.ajo.2010.08.027.
- Cursiefen C, Jun AS. Current treatment options for fuchs endothelial dystrophy. Switzerland: Springer 978-3-319-43019-5 ; 2017.
- Wang YE, Li Y, Wang D, He M, Lin S. Comparison of factors associated with occludable angle between American caucasians and ethnic Chinese. Invest Ophthalmol Vis Sci. 2013;54:7717–23. doi:https://doi.org/10.1167/iovs.13-12850.
- Khor WB, Han SB, Mehta JS, Tan DTH. Descemet stripping automated endothelial keratoplasty with a donor insertion device: clinical results and complications in 100 eyes. Am J Ophthalmol. 2013;156:773–79. doi:https://doi.org/10.1016/j.ajo.2013.05.012.
- Ang M, Saroj L, Htoon HM, Kiew S, Mehta JS, Tan D. Comparison of a donor insertion device to sheets glide in Descemet stripping endothelial keratoplasty: 3-year outcomes. Am J Ophthalmol. 2014;157:1163–1169.e3. doi:https://doi.org/10.1016/j.ajo.2014.02.049.
- Yokogawa H, Kobayashi A, Sugiyama K. Clinical evaluation of a new donor graft inserter for Descemet’s stripping automated endothelial keratoplasty. Ophthalmic Surg Lasers Imaging. 2012;43:50–56. doi:https://doi.org/10.3928/15428877-20111129-08.
- Balidis M, Konidaris VE, Ioannidis G, Boboridis K. Descemet’s stripping endothelial automated keratoplasty using Tan EndoGlide endothelium insertion system. Transplant Proc. 2012;44:2759–64. doi:https://doi.org/10.1016/j.transproceed.2012.09.006.
- Elbaz U, Yeung SN, Lichtinger A, Zauberman NA, Goldich Y, Ziai S, Chan CC, Rootman DS, Slomovic AR. EndoGlide versus EndoSerter for the insertion of donor graft in descemet stripping automated endothelial keratoplasty. Am J Ophthalmol. 2014;158:257–262.e1. doi:https://doi.org/10.1016/j.ajo.2014.05.012.
- Foster JB, Swan KR, Vasan RA, Greven MA, Walter KA. Small-incision Descemet stripping automated endothelial keratoplasty: a comparison of small-incision tissue injector and forceps techniques. Cornea. 2012;31:42–47. doi:https://doi.org/10.1097/ICO.0b013e3182120f9d.
- Terry MA, Straiko MD, Goshe JM, Shamie N, Shah A, Alqudah AA, Davis-Boozer D. Endothelial keratoplasty: prospective, randomized, masked clinical trial comparing an injector with forceps for tissue insertion. Am J Ophthalmol. 2013;156:61–68.e3. doi:https://doi.org/10.1016/j.ajo.2013.01.025.
- Kobayashi A, Yokogawa H, Sugiyama K. Clinical results of the Neusidl Corneal Inserter(®), a new donor inserter for Descemet’s stripping automated endothelial keratoplasty, for small Asian eyes. Ophthalmic Surg Lasers Imaging. 2012;43:311–18. doi:https://doi.org/10.3928/15428877-20120426-04.
- Soma T, Koh S, Maeda N, Mitomo K, Quantock AJ, Nishida K. New graft insertion device for descemet stripping automated endothelial keratoplasty. Cornea. 2017;36:1432–36. doi:https://doi.org/10.1097/ICO.0000000000001302.
- Soma T, Koh S, Maeda N, Nishida K. NS endo-inserter: a new graft inserter for descemet stripping automated endothelial keratoplasty. Cornea. 2019;38:S42–S44. doi:https://doi.org/10.1097/ICO.0000000000002086.
- Yokogawa H, Kobayashi A, Mori N, Nishino T, Sugiyama K. Clinical evaluation of the “Lifeline suture” technique for DSAEK in cases without posterior capsule using a novel donor insertion device. Cornea. 2020;39:523–26. doi:https://doi.org/10.1097/ICO.0000000000002223.
- Kobayashi A, Yokogawa H, Mori N, Nishino T, Sugiyama K. Clinical evaluation of the NS endo-inserter, a novel donor inserter for descemet’s stripping automated endothelial keratoplasty. Case Rep Ophthalmol. 2019;10:357–64. doi:https://doi.org/10.1159/000503441.
- Tsatsos M, Athanasiadis I, Kopsachilis N, Krishnan R, Hossain P, Anderson D. Comparison of the Endosaver with noninjector techniques in Descemet’s stripping endothelial keratoplasty. Indian J Ophthalmol. 2017;65:1133–37. doi:https://doi.org/10.4103/ijo.IJO_360_17.
- Macaluso C. Closed-chamber pulling-injection system for donor graft insertion in endothelial keratoplasty. J Cataract Refract Surg. 2008; 34: 353–56. doi:https://doi.org/10.1016/j.jcrs.2007.11.019.
- Parekh M, Baruzzo M, Favaro E, Borroni D, Ferrari S, Ponzin D, Ruzza A. Standardizing Descemet membrane endothelial keratoplasty graft preparation method in the eye bank – experience of 527 Descemet membrane endothelial keratoplasty tissues. Cornea. 2017;36:1458–66. doi:https://doi.org/10.1097/ICO.0000000000001349.
- Price M, Matthew F, Francis P. Endothelial keratoplasty update 2020. Cornea. 2021;40:541–47. doi:https://doi.org/10.1097/ICO.0000000000002565.
- Arnalich-Montiel F, Hernández-Verdejo JL, Oblanca N, Muñoz-Negrete FJ, De Miguel MP. Comparison of corneal haze and visual outcome in primary DSAEK versus DSAEK following failed DMEK. Graefes Arch Clin Exp Ophthalmol. 2013;251:2575–84. doi:https://doi.org/10.1007/s00417-013-2460-y.
- Dirisamer M, van Dijk K, Dapena I, Ham L, Oganes O, Frank L, Melles G. Prevention and management of graft detachment in descemet membrane endothelial keratoplasty. Arch Ophthalmol. 2012;130:280–91. doi:https://doi.org/10.1001/archophthalmol.2011.343.
- Quilendrino R, Rodriguez-calvo de Mora M, Baydoun L, Ham L, van Dijk K, Dapena I, Oellerich S, Melles GRJ. Prevention and management of descemet membrane endothelial keratoplasty complications. Cornea. 2017;36:1089–95. doi:https://doi.org/10.1097/ICO.0000000000001262.
- Milojcic C, Latz C, Tandogan T, Auffarth GU, Holz FG, Choi CY, Khoramnia R. Opacification of a hydrophilic acrylic intraocular lens after DMEK: a material analysis. Ophthalmologe. 2017;114:832–37. doi:https://doi.org/10.1007/s00347-016-0394-6.
- Leon P, Parekh M, Nahum Y, Mimouni M, Giannaccare G, Sapigni L, Ruzza A, Busin M. Factors associated with early graft detachment in primary descemet membrane endothelial keratoplasty. Am J Ophthalmol. 2018;187:117–24. doi:https://doi.org/10.1016/j.ajo.2017.12.014.
- Feng MT, Price MO, Miller JM, Price FW. Air reinjection and endothelial cell density in Descemet membrane endothelial keratoplasty: five-year follow-up. J Cataract Refract Surg. 2014;40:1116–21. doi:https://doi.org/10.1016/j.jcrs.2014.04.023.
- Gorovoy IR, Gorovoy MS. Descemet membrane endothelial keratoplasty postoperative year 1 endothelial cell counts. Am J Ophthalmol. 2015;159:597–600, e2. doi:https://doi.org/10.1016/j.ajo.2014.12.008.
- Tourtas T, Laaser K, Bachmann BO, Cursiefen C, Kruse FE. Descemet membrane endothelial keratoplasty versus descemet stripping automated endothelial keratoplasty. Am J Ophthalmol. 2012;153:1082–1090.e2. doi:https://doi.org/10.1016/j.ajo.2011.12.012.
- Guerra FP, Anshu A, Price MO, Giebel AW, Price FW. Descemet’s membrane endothelial 47 keratoplasty: prospective study of 1-year visual outcomes, graft survival, and endothelial cell loss. Ophthalmology. 2011;118:2368–73. doi:https://doi.org/10.1016/j.ophtha.2011.06.002.
- Ham L, van Luijk C, Dapena I, Wong TH, Birbal R, van der Wees J, Melles GRJ. Endothelial cell density after descemet membrane 85 endothelial keratoplasty: 1- to 2-year follow-up. Am J Ophthalmol. 2009;148:521–27. doi:https://doi.org/10.1016/j.ajo.2009.04.025.
- Ham L, Dapena I, van Luijk C, van der Wees J, Melles GRJ. Descemet membrane endothelial keratoplasty (DMEK) for Fuchs endothelial dystrophy: review of the first 50 consecutive cases. Eye (Lond). 2009;23:1990–98. doi:https://doi.org/10.1038/eye.2008.393.
- Laaser K, Bachmann BO, Horn FK, Schlötzer-Schrehardt U, Cursiefen C, Kruse FE. Donor tissue culture conditions and outcome after descemet membrane endothelial keratoplasty. Am J Ophthalmol. 2011;151:1007–1018 e2. doi:https://doi.org/10.1016/j.ajo.2010.11.027.
- Laaser K, Bachmann BO, Horn FK, Cursiefen C, Kruse FE. Descemet membrane endothelial keratoplasty combined with phacoemulsification and intraocular lens implantation: advanced triple procedure. Am J Ophthalmol. 2012;154:47–55 e2. doi:https://doi.org/10.1016/j.ajo.2012.01.020.
- Dirisamer M, Ham L, Dapena I, Moutsouris K, Droutsas K, van Dijk K, Frank LE, Oellerich S, Melles GRJ. Efficacy of descemet membrane endothelial 48 keratoplasty: clinical outcome of 200 consecutive cases after a learning curve of 25 cases. Arch Ophthalmol. 2011;129:1435–43. doi:https://doi.org/10.1001/archophthalmol.2011.195.
- Baydoun L, Tong CM, Tse WW, Chi H, Parker J, Ham L, Melles GRJ. Endothelial cell density after descemet membrane endothelial keratoplasty: 1 to 5-year follow-up. Am J Ophthalmol. 2012;154:762–63. doi:https://doi.org/10.1016/j.ajo.2012.06.025.
- Parekh M, Ruzza A, Ferrari S, Ahmad S, Kaye S, Ponzin D, Romano V. Endothelium-in versus endothelium-out for Descemet membrane endothelial keratoplasty graft preparation and implantation. Acta Ophthalmol. 2017;95:194–98. doi:https://doi.org/10.1111/aos.13162.
- Busin M, Leon P, D’Angelo S, Ruzza A, Ferrari S, Ponzin D, Parekh M. Clinical outcomes of preloaded Descemet membrane endothelial keratoplasty grafts with endothelium Tri-folded inwards. Am J Ophthalmol. 2018;193:106–13. doi:https://doi.org/10.1016/j.ajo.2018.06.013.
- Price MO, Lisek M, Kelley M, Feng M, Price FW. Endothelium-in versus endothelium-out insertion with Descemet membrane endothelial keratoplasty. Cornea. 2018;37:1098–101. doi:https://doi.org/10.1097/ICO.0000000000001650.
- Newman LR, DeMill DL, Zeidenweber DA, Mayko ZM, Bauer AJ, Tran KD, Straiko MD, Terry MA. Preloaded Descemet membrane endothelial keratoplasty donor tissue: surgical technique and early clinical results. Cornea. 2018;37:981–86. doi:https://doi.org/10.1097/ICO.0000000000001646.
- Terry MA. Deep lamellar endothelial keratoplasty (DLEK): pursuing the ideal goals of endothelial replacement. Eye (Lond). 2003;17:982–88. doi:https://doi.org/10.1038/sj.eye.6700614.
- Röck D, Röck T, Bartz-Schmidt K-U, Yoeruek E. Descemet membrane endothelial keratoplasty in cases with existing scleral-sutured and iris-sutured intraocular lenses. BMC Ophthalmol. 2014;14:6. doi:https://doi.org/10.1186/1471-2415-14-6.
- Parekh M, Ruzza A, Ferrari S, Busin M, Ponzin D. Preloaded tissues for descemet membrane endothelial keratoplasty. Am J Ophthalmol. 2016;166:120–25. doi:https://doi.org/10.1016/j.ajo.2016.03.048.
- Downes K, Tran KD, Stoeger CG, Chamberlain W. Cumulative endothelial cell loss in descemet membrane endothelial keratoplasty grafts from preparation through insertion with glass injectors. Cornea. 2018;37:698–704. doi:https://doi.org/10.1097/ICO.0000000000001588.
- Droutsas K, Lazaridis A, Kymionis GD, Chatzistefanou K, Moschos MM, Koutsandrea C, Sekundo W. Comparison of endothelial cell loss and complications following DMEK with the use of three different graft injectors. Eye (Lond). 2018;32:19–25.64. doi:https://doi.org/10.1038/eye.2017.237.
- Arnalich-Montiel F, Muñoz-Negrete FJ, De Miguel MP. Double port injector device to reduce endothelial damage in DMEK. Eye (Lond). 2014;28:748–51. doi:https://doi.org/10.1038/eye.2014.67.
- Rossler K, Bachmann BO, Armitage J, Tourtas T, Schlotzer-Schrehardt U, Dockhorn V, Hohl E, Kruse FE. Experimental evaluation of the novel ENDOJECT TM injector for the implantation of descemet’s membrane into the anterior chamber during DMEK. Association for research in vision and ophthalmology. Seattle (WA): IOVS; 2014. 55.
- Tan TE, Devarajan K, Seah XY, Lin SJ, Peh GSL, Cajucom-Uy HY, Ang M, Mehta JS, Tan DTH. Descemet membrane endothelial keratoplasty with a pull-through insertion device: surgical technique, endothelial cell loss, and early clinical results. Cornea. 2020;39:558–65. doi:https://doi.org/10.1097/ICO.0000000000002268.
- Woo JH, Htoon HM, Tan D. Hybrid descemet membrane endothelial keratoplasty (H-DMEK): results of a donor insertion pull-through technique using donor stroma as carrier. Br J Ophthalmol. 2020;104:1358–62. doi:https://doi.org/10.1136/bjophthalmol-2019-314932.
- Ang M, Mehta JS, Newman SD, Han SB, Chai J, Tan D. Descemet membrane endothelial keratoplasty: preliminary results of a donor insertion pull-through technique using a donor mat device. Am J Ophthalmol. 2016;171:27–34. doi:https://doi.org/10.1016/j.ajo.2016.08.023.
- Ighani M, Dzhaber D, Jain S, DeRojas J, Eghrari A. Techniques outcomes, and complications of preloaded, trifolded descemet membrane endothelial keratoplasty using the DMEK EndoGlide. Cornea. 2021;40:669–74. doi:https://doi.org/10.1097/ICO.0000000000002648.
- Kim EC, Bonfadini G, Todd L, Zhu A, Jun AS. Simple, inexpensive, and effective injector for descemet membrane endothelial keratoplasty. Cornea. 2014;33:649–52. doi:https://doi.org/10.1097/ICO.0000000000000121.
- Tran KD, Dye PK, Odell K, Galloway J, Stoeger CG, Straiko MD, Terry MA. Evaluation and quality assessment of prestripped, preloaded descemet membrane endothelial keratoplasty grafts. Cornea. 2017;36:484–90. doi:https://doi.org/10.1097/ICO.0000000000001150.
- Ighani M, Karakus S, Eghrari AO. Clinical outcomes of descemet membrane endothelial keratoplasty using the bonfadini-todd injector for graft insertion. Clin Ophthalmol. 2019;13:1869–76. doi:https://doi.org/10.2147/OPTH.S219742.
- Schallhorn JM, Holiman JD, Stoeger CG, Chamberlain W. Quantification and patterns of endothelial cell loss due to eye bank preparation and injector method in descemet membrane endothelial keratoplasty tissues. Cornea. 2016;35:377–82. doi:https://doi.org/10.1097/ICO.0000000000000690.
- Shen E, Fox A, Johnson B, Farid M. Comparing the effect of three descemet membrane endothelial keratoplasty injectors on endothelial damage of grafts. Indian J Ophthalmol. 2020;68:1040–43. doi:https://doi.org/10.4103/ijo.IJO_1280_19.
- Catala P, Vermeulen W, Rademakers T, van Den Bogaerdt A, Kruijt PJ, Nuijts RMMA, LaPointe VLS. Transport and preservation comparison of preloaded and prestripped-only DMEK grafts. Cornea. 2020;39:1407–14. doi:https://doi.org/10.1097/ICO.0000000000002391.
- Wojcik G, Parekh M, Romano V, Ferrari S, Ruzza A, Ahmad S, Ponzin D. Pre-loaded DMEK grafts with endothelium outwards: a cross-country validation study of DMEK Rapid device. Cornea. 2020;40:484–90.
- Rickmann A, Wahl S, Hofmann N, Knakowski J, Haus A, Börgel M, Szurman P. Comparison of preloaded grafts for Descemet membrane endothelial keratoplasty (DMEK) in a novel preloaded transport cartridge compared to conventional precut grafts. Cell Tissue Bank. 2020;21:205–13. doi:https://doi.org/10.1007/s10561-020-09814-7.
- Rickmann A, Wahl S, Katsen-Globa A, Szurman P. Safety analysis and results of a borosilicate glass cartridge for no-touch graft loading and injection in Descemet membrane endothelial keratoplasty. Int Ophthalmol. 2019;39:2295–301. doi:https://doi.org/10.1007/s10792-018-01067-4.
- Parekh M, Ferrari S, Pagano L, Angi M, Gadhvi KA, Romano V. Confounding factors influencing the scroll width of Descemet membrane endothelial keratoplasty graft. Indian J Ophthalmol. 2021;69:461–62. doi:https://doi.org/10.4103/ijo.IJO_2642_20.
- Romano V, Parekh M, Ruzza A, Willoughby CE, Ferrari S, Ponzin D, Kaye SB, Levis HJ. Comparison of preservation and transportation protocols for preloaded Descemet membrane endothelial keratoplasty. Br J Ophthalmol. 2018;102:549–55. doi:https://doi.org/10.1136/bjophthalmol-2017-310906.
- Levis HJ, Peh GSL, Toh KP, Poh R, Shortt AJ, Drake RAL, Mehta JS, Daniels JT. Plastic compressed collagen as a novel carrier for expanded human corneal endothelial cells for transplantation. PLoS One. 2012;7:e50993. doi:https://doi.org/10.1371/journal.pone.0050993.
- Cheung AY, Hou JH, Bedard P, Grimes V, Buckman N, Eslani M, Holland EJ. Technique for preparing ultrathin and nanothin descemet stripping automated endothelial keratoplasty tissue. Cornea. 2018;37:661–66. doi:https://doi.org/10.1097/ICO.0000000000001510.
- Gerber-Hollbach N, Parker J, Baydoun L, Liarakos VS, Ham L, Dapena I, Melles GR. Preliminary outcome of hemi-Descemet membrane endothelial keratoplasty for Fuchs endothelial dystrophy. Br J Ophthalmol. 2016;100:1564–68. doi:https://doi.org/10.1136/bjophthalmol-2015-307783.
- Zygoura V, Baydoun L, Ham L, Bourgonje VJA, van Dijk K, Lie JT, Dapena I, Oellerich S, Melles GRJ. Quarter-Descemet membrane endothelial keratoplasty (Quarter-DMEK) for Fuchs endothelial corneal dystrophy: 6 months clinical outcome. Br J Ophthalmol. 2018;102:1425–30. doi:https://doi.org/10.1136/bjophthalmol-2017-311398.
- Artieda JA, Wells M, Devasahayam RN, Moloney G. 5-Year outcomes of descemet stripping only in fuchs dystrophy. Cornea. 2020;39:1048–51. doi:https://doi.org/10.1097/ICO.0000000000002270.
- Parekh M, Graceffa V, Bertolin M, Elbadawy H, Salvalaio G, Ruzza A, Camposampiero D, Almarza Gomez D, Barbaro V, Ferrari B, Breda C, Ponzin D, Ferrari S. Reconstruction and regeneration of corneal endothelium: a review on current methods and future aspects. J Cell Sci Ther. 2013;4:1–8.
- Parekh M, Ferrari S, Sheridan C, Kaye S, Ahmad S. Concise review: an update on the culture of human corneal endothelial cells for transplantation. Stem Cells Transl Med. 2016;5:258–64. doi:https://doi.org/10.5966/sctm.2015-0181.
- Parekh M, Romano V, Hassanin K, Testa V, Wongvisavavit R, Ferrari S, Haneef A, Willoughby C, Ponzin D, Jhanji V, et al. Biomaterials for corneal endothelial cell culture and tissue engineering. J Tissue Eng. 2021 Feb 16;12:2041731421990536. doi:https://doi.org/10.1177/2041731421990536.
- Peh GS, Toh KP, Wu FY, Tan DT, Mehta JS. Cultivation of human corneal endothelial cells isolated from paired donor corneas. PLoS One. 2011;6:e28310. doi:https://doi.org/10.1371/journal.pone.0028310.
- Okumura N, Koizumi N, Ueno M, Sakamoto Y, Takahashi H, Tsuchiya H, Hamuro J, Kinoshita S. ROCK inhibitor converts corneal endothelial cells into a phenotype capable of regenerating in vivo endothelial tissue. Am J Pathol. 2012;181:268–77. doi:https://doi.org/10.1016/j.ajpath.2012.03.033.
- Kinoshita S, Koizumi N, Ueno M, Okumura N, Imai K, Tanaka H, Yamamoto Y, Nakamura T, Inatomi T, Bush J, et al. Injection of cultured cells with a ROCK inhibitor for bullous keratopathy. N Engl J Med. 2018;378(11):995–1003. doi:https://doi.org/10.1056/NEJMoa1712770.