REFERENCES
- Bourrous, S., Bouilloux, L., Ouf, F.-X., Appert-Collin, J.-C., Thomas, D., Tampère, L., et al. (2014). Measurement of the Nanoparticles Distribution in Flat and Pleated Filters During Clogging. Aerosol Sci. Tech., 48(4):392–400.
- Del Fabbro, L., Laborde, J.-C., Merlin, P., and Ricciardi, L. (2002). Air Flows and Pressure Drop Modelling for Different Pleated Industrial Filters. Filtr., Sep. 39:35–40.
- Elmøe, T. D., Tricoli, A., Grunwaldt, J.-D., and Pratsinis, S. E. (2009). Filtration of Nanoparticles: Evolution of Cake Structure and Pressure-Drop. J. Aerosol Sci., 40:965–981.
- Gregory, W. S., Martin, R. A., White, B. W., Nichols, B. D., Smith, P. R., Leslie, I. H., et al. (1991). Fires in Large Scale Ventilation Systems. Nucl. Eng. Des., 125:337–345.
- Hashimoto, K., Nishio, G., and Soda, K. (1993). Fire Behaviour and Filter Plugging During a Postulated Solvent Fire in the Extraction Process of a Nuclear Fuel Reprocessing Plant. Nucl. Tech., 101(2):218–226.
- Joubert, A., Laborde, J.-C., Bouilloux, L., Callé-Chazelet, S., and Thomas, D. (2010). Influence of Humidity on Clogging of Flat and Pleated HEPA Filters. Aerosol Sci. Tech., 44(12):1065–1076.
- Kim, S. C., Wang, J., Shin, G. W., Scheckmann, J. H., and Pui, D. Y. H. (2009). Structural Properties and Filter Loading Characteristics of Soot Agglomerates. Aerosol Sci. Tech., 43(4):344–355.
- Kozeny, J. (1927). Über die kapillare Leitung des Wassers im Boden, Sitzungsberichte der Akademie der Wissenschaften Wien, 136:271–306.
- Le Saux, W., Pretrel, H., and Such, J.-M. (2005). The DIVA ‘multi-room’ Experimental Facility and the DIVA-0 Program. 8th International Symposium on Fire Safety Science, Beijing, China.
- Mädler, L., Lall, A. A., and Friedlander, K. (2006). One-Step Aerosol Synthesis of Nanoparticle Agglomerate Films: Simulation of Film Porosity and Thickness. Nanotech., 17:4783–4795.
- Mocho, V.-M., and Ouf, F.-X. (2011). Clogging of Industrial Pleated High Efficiency Particulate Air (HEPA) Filters in the Event of Fire. Nucl. Eng. Des., 241:1785–1794.
- Novick, V. J., Monson, P. R., and Ellison, P. E. (1992). The Effect of Solid Particle Mass Loading on the Pressure Drop of HEPA Filters. J. Aerosol Sci., 23:657–665.
- Ouf, F.-X., Mocho, V.-M., Pontreau, S., Wang, Z., Ferry, D., and Yon, J. (2014). Physico-Chemical Properties of Aerosol Emitted in Case of Fire Involving Materials Used in the Nuclear Industry. J. Hazard. Mater.
- Ouf, F.-X., Vendel, J., Coppalle, A., Weill, M., and Yon, J. (2008). Characterization of Soot Particles in the Plumes of Over-Ventilated Diffusion Flames. Comb. Sci. Tech., 180:674–698.
- Ouf, F.-X., Yon, J., Ausset, P., Coppalle, A., and Maillé, M. (2010). Influence of Sampling and Storage Protocol on Fractal Morphology of Soot Studied by Transmission Electron Microscopy. Aerosol Sci. Tech., 44:1005–1017.
- Popovicheva, O. B., Persiantseva, N. M., Tishkova, V., Shonija, N. K., and Zubareva, N. A. (2008). Quantification of Water Uptake by Soot Particles. Environ. Res. Lett., 3:025009.
- Thomas, D., Penicot, P., Contal, P., Leclerc, D., and Vendel, J. (2001). Clogging of Fibrous Filters by Solid Aerosol Particles: Experimental and Modelling Study. Chem. Eng. Sci., 56:3549–3561.