1,973
Views
30
CrossRef citations to date
0
Altmetric
Original Articles

Sub-3 nm Particle Detection with Commercial TSI 3772 and Airmodus A20 Fine Condensation Particle Counters

, , , , &
Pages 674-681 | Received 22 Aug 2014, Accepted 24 May 2015, Published online: 06 Jul 2015

REFERENCES

  • Agarwal, J. K., and Sem, G. J. (1980). Continuous-Flow, Single-Particle-Counting Condensation Nucleus Counter. J. Aerosol Sci., 11:343, doi: 10.1016/0021-8502(80)90042-7.
  • Ahn, K. H., and Liu, B. Y. H. (1990). Particle Activation and Droplet Growth-Processes in Condensation Nucleus Counter. 2. Experimental-Study. J. Aerosol Sci., 21:263–275, doi: 10.1016/0021-8502(90)90009-M.
  • Bartz, H., Fissan, H., Helsper, C., Kousaka, Y., Okuyama, K., Fukushima, N., Keady, P. B., Kerrigan, S., Fruin, S. A., McMurry, P. H., Pui, D. Y. H., and Stolzenburg, M. R. (1985). Response Characteristics for 4 Different Condensation Nucleus Counters to Particles in the 3-50 Nm Diameter Range. J. Aerosol Sci., 16:443–456, doi: 10.1016/0021-8502(85)90056-4.
  • Gamero-Castano, M., and de la Mora, J. F. (2000). A Condensation Nucleus Counter (CNC) Sensitive to Singly Charged Sub-Nanometer Particles. J. Aerosol Sci., 31:757–772, doi: 10.1016/S0021-8502(99)00555-8.
  • Giechaskiel, B., Wang, X., Gilliland, D., and Drossinos, Y. (2011). The Effect of Particle Chemical Composition on the Activation Probability in n-butanol Condensation Particle Counters. J. Aerosol Sci., 42:20–37, doi: 10.1016/j.jaerosci.2010.10.006.
  • Gormley, P.G., and Kennedy, M. (1949). Diffusion from a Stream Flowing Through a Cylindrical Tube, in Proceedings of the Royal Irish Academy, 52A, pp. 163–169.
  • Hering, S. V., Stolzenburg, M. R., Quant, F. R., Oberreit, D. R., and Keady, P. B. (2005). A Laminar-Flow, Water-Based Condensation Particle Counter (WCPC). Aerosol Sci. Tech., 39:659–672, doi: 10.1080/02786820500182123.
  • Herrmann, W., Eichler, T., Bernardo, N., and Fernández de la Mora, J. (2000). Turbulent Transition Arises at Reynolds Number 35,000 in a Short Vienna Type DMA with a Large Laminarization Inlet. Abstract AAAR Conference, 15B5.
  • Iida, K., Stolzenburg, M. R., McMurry, P. H., Smith, J. N., Quant, F. R., Oberreit, D. R., Keady, P. B., Eiguren-Fernandez, A., Lewis, G. S., Kreisberg, N. M., and Hering, S. V. (2008). An Ultrafine, Water-based Condensation Particle Counter and its Evaluation Under Field Conditions. Aerosol Sci. Tech., 42:862–871, doi: 10.1080/02786820802339579.
  • Iida, K., Stolzenburg, M. R., and McMurry, P. H. (2009). Effect of Working Fluid on Sub-2 nm Particle Detection with a Laminar Flow Ultrafine Condensation Particle Counter. Aerosol Sci. Tech., 43:81–96, doi: 10.1080/02786820802488194.
  • Jiang, J. K., Zhao, J., Chen, M. D., Eisele, F. L., Scheckman, J., Williams, B. J., Kuang, C. A., and McMurry, P. H. (2011). First Measurements of Neutral Atmospheric Cluster and 1–2 nm Particle Number Size Distributions During Nucleation Events. Aerosol Sci. Tech., 45:Ii-V, doi: 10.1080/02786826.2010.546817.
  • Kangasluoma, J., Junninen, H., Lehtipalo, K., Mikkila, J., Vanhanen, J., Attoui, M., Sipila, M., Worsnop, D., Kulmala, M., and Petaja, T. (2013). Remarks on Ion Generation for CPC Detection Efficiency Studies in Sub-3-nm Size Range. Aerosol Sci. Tech., 47:556–563, doi: 10.1080/02786826.2013.773393.
  • Kangasluoma, J., Kuang, C., Wimmer, D., Rissanen, M. P., Lehtipalo, K., Ehn, M., Worsnop, D. R., Wang, J., Kulmala, M., and Petaja, T. (2014). Sub-3 nm Particle Size and Composition-Dependent Response of a Nano-CPC Battery. Atmos. Meas. Tech., 7:689–700, doi: 10.5194/amt-7-689-2014.
  • Kangasluoma, J., Attoui, M., Junninen, H., Lehtipalo, K., Samodurov, A., Korhonen, F., Sarnela, N., Schmidt-Ott, A., Worsnop, D., Kulmala, M., and Petäjä, T. (2015). Sizing of Neutral Sub 3 nm Tungsten Oxide Clusters using Airmodus Particle Size Magnifier. Journal of Aerosol Science, 87:53–62.
  • Kim, C. S., Okuyama, K., and Shimada, M. (2002). Performance of a Mixing-type CNC for Nanoparticles at Low-Pressure Conditions. J. Aerosol Sci., 33:1389–1404, Pii S0021-8502(02)00092-7, doi: 10.1016/S0021-8502(02)00092-7.
  • Kuang, C., Chen, M., Zhao, J., Smith, J., McMurry, P. H., and Wang, J. (2012a). Size and Time-Resolved Growth Rate Measurements of 1 to 5 nm Freshly Formed Atmospheric Nuclei. Atmos. Chem. Phys., 12:3573–3589, doi: 10.5194/acp-12-3573-2012.
  • Kuang, C. A., Chen, M. D., McMurry, P. H., and Wang, J. (2012b). Modification of Laminar Flow Ultrafine Condensation Particle Counters for the Enhanced Detection of 1 nm Condensation Nuclei. Aerosol Sci. Tech., 46:309–315, doi: 10.1080/02786826.2011.626815.
  • Kulmala, M., Mordas, G., Petaja, T., Gronholm, T., Aalto, P. P., Vehkamaki, H., Hienola, A. I., Herrmann, E., Sipila, M., Riipinen, I., Manninen, H. E., Hameri, K., Stratmann, F., Bilde, M., Winkler, P. M., Birmili, W., and Wagner, P. E. (2007). The Condensation Particle Counter Battery (CPCB): A New Tool to Investigate the Activation Properties of Nanoparticles. J. Aerosol Sci., 38:289–304, doi: 10.1016/j.jaerosci.2006.11.008.
  • Kulmala, M., Kontkanen, J., Junninen, H., Lehtipalo, K., Manninen, H. E., Nieminen, T., Petaja, T., Sipila, M., Schobesberger, S., Rantala, P., Franchin, A., Jokinen, T., Jarvinen, E., Aijala, M., Kangasluoma, J., Hakala, J., Aalto, P. P., Paasonen, P., Mikkila, J., Vanhanen, J., Aalto, J., Hakola, H., Makkonen, U., Ruuskanen, T., Mauldin, R. L., Duplissy, J., Vehkamaki, H., Back, J., Kortelainen, A., Riipinen, I., Kurten, T., Johnston, M. V., Smith, J. N., Ehn, M., Mentel, T. F., Lehtinen, K. E. J., Laaksonen, A., Kerminen, V. M., and Worsnop, D. R. (2013). Direct Observations of Atmospheric Aerosol Nucleation. Science, 339:943–946, doi: 10.1126/science.1227385.
  • Kurten, A., Curtius, J., Helleis, F., Lovejoy, E. R., and Borrmann, S. (2007). Development and Characterization of an Ion Trap Mass Spectrometer for the On-Line Chemical Analysis of Atmospheric Aerosol Particles. Int. J. Mass. Spectrom., 265:30–39, doi: 10.1016/j.ijms.2007.05.007.
  • Lehtipalo, K., Leppä, J., Kontkanen, J., Kangasluoma, J., Franchin, A., Wimmer, D., Schobesberger, S., Junninen, H., Petäjä, T., Sipilä, M., Mikkilä, J., Vanhanen, J., Worsnop, D. R., and Kulmala, M. (2014). Methods for Determining Particle Size Distribution and Growth Rates Between 1 and 3 nm using the Particle Size Magnifier. Boreal Env. Res, 19 (Suppl. B):215–236.
  • Magnusson, L. E., Koropchak, J. A., Anisimov, M. P., Poznjakovskiy, V. M., and de la Mora, J. F. (2003). Correlations for Vapor Nucleating Critical Embryo Parameters. J. Phys. Chem. Ref. Data, 32:1387–1410, doi: 10.1063/1.1555590.
  • McMurry, P. H. (2000). The History of Condensation Nucleus Counters. Aerosol Sci. Tech., 33:297–322, doi: 10.1080/02786820050121512.
  • McMurry, P. H., Kulmala, M., and Worsnop, D. R. (2011). Special Issue on Aerosol Measurements in the 1 nm Range. Aerosol Sci. Technol., 45, i.
  • Mertes, S., Schroder, F., and Wiedensohler, A. (1995). The Particle-Detection Efficiency Curve of the Tsi-3010 Cpc as a Function of the Temperature Difference between Saturator and Condenser. Aerosol Sci. Tech., 23:257–261, doi: 10.1080/02786829508965310.
  • OpenFOAM (2015). The Open Source CFD Toolbox, available at: http://www.openfoam.org (accessed 26 November 2014).
  • Peineke, C., Attoui, M. B., and Schmidt-Ott, A. (2006). Using a Glowing Wire Generator for Production of Charged, Uniformly Sized Nanoparticles at High Concentrations. J. Aerosol Sci., 37:1651–1661, doi: 10.1016/j.jaerosci.2006.06.006.
  • Peineke, C., and Schmidt-Ott, A. (2008). Explanation of Charged Nanoparticle Production from Hot Surfaces. J. Aerosol Sci., 39:244–252, doi: 10.1016/j.jaerosci.2007.12.004.
  • Reischl, G. P., Makela, J. M., Karch, R., and Necid, J. (1996). Bipolar Charging of Ultrafine Particles in the Size Range Below 10 nm. J. Aerosol Sci., 27:931–949, doi: 10.1016/0021-8502(96)00026-2.
  • Russell, L. M., Zhang, S. H., Flagan, R. C., Seinfeld, J. H., Stolzenburg, M. R., and Caldow, R. (1996). Radially Classified Aerosol Detector for Aircraft-Based Submicron Aerosol Measurements. J. Atmosp. Oceanic Technol., 13:598–609, doi: 10.1175/1520-0426(1996)013<0598:Rcadfa>2.0.Co;2.
  • Scheibel, H. G., and Porstendorfer, J. (1986). Counting Efficiency and Detection Limit of Condensation Nuclei Counters for Submicrometer Aerosols .1. Theoretical Evaluation of the Influence of Heterogeneous Nucleation and Wall Losses. J. Colloid. Interf. Sci., 109:261–274, doi: 10.1016/0021-9797(86)90301-2.
  • Seto, T., Okuyama, K., deJuan, L., and delaMora, J. F. (1997). Condensation of Supersaturated Vapors on Monovalent and Divalent Ions on Varying Size. J. Chem. Phys., 107:1576–1585, doi: 10.1063/1.474510.
  • Sgro, L. A., and de la Mora, J. F. (2004). A Simple Turbulent Mixing CNC for Charged Particle Detection Down to 1.2 nm. Aerosol Sci. Tech., 38:1–11, doi: 10.1080/02786820490247560.
  • Sipilä, M., Lehtipalo, K., Attoui, M., Neitola, K., Petaja, T., Aalto, P. P., O’Dowd, C. D., and Kulmala, M. (2009). Laboratory Verification of PH-CPC's Ability to Monitor Atmospheric Sub-3 nm Clusters. Aerosol Sci. Tech., 43:126–135, doi: 10.1080/02786820802506227.
  • Stolzenburg, M. R., and McMurry, P. H. (1991). An Ultrafine Aerosol Condensation Nucleus Counter. Aerosol Sci. Tech., 14:48–65, doi: 10.1080/02786829108959470.
  • Stratmann, F., Herrmann, E., Petaja, T., and Kulmala, M. (2010). Modelling Ag-Particle Activation and Growth in a TSI WCPC Model 3785. Atmos. Meas. Tech., 3:273–281.
  • Su, Y. F., Cheng, Y. S., Newton, G. J., and Yeh, H. C. (1990). Counting Efficiency of the Tsi Model 3020 Condensation Nucleus Counter. Aerosol Sci. Tech., 12:1050–1054, doi: 10.1080/02786829008959414.
  • Vanhanen, J., Mikkila, J., Lehtipalo, K., Sipila, M., Manninen, H. E., Siivola, E., Petaja, T., and Kulmala, M. (2011). Particle Size Magnifier for Nano-CN Detection. Aerosol Sci. Tech., 45:533–542, doi: 10.1080/02786826.2010.547889.
  • Weber, R. J., Stolzenburg, M. R., Pandis, S. N., and McMurry, P. H. (1998). Inversion of Ultrafine Condensation Nucleus Counter Pulse Height Distributions to Obtain Nanoparticle (Similar to 3–10 nm) Size Distributions. J. Aerosol Sci., 29:601–615, doi: 10.1016/S0021-8502(97)10026-X.
  • Weller, H. G., Tabor, G., Jasak, H., and Fureby, C. (1998). A Tensorial Approach to Computational Continuum Mechanics Using Object-Oriented Techniques. Comp. Phys., 12:620–631, doi: 10.1063/1.168744.
  • Wiedensohler, A., Orsini, D., Covert, D. S., Coffmann, D., Cantrell, W., Havlicek, M., Brechtel, F. J., Russell, L. M., Weber, R. J., Gras, J., Hudson, J. G., and Litchy, M. (1997). Intercomparison Study of the Size-Dependent Counting Efficiency of 26 Condensation Particle Counters. Aerosol Sci. Tech., 27:224–242, doi: 10.1080/02786829708965469.
  • Wilson, J. C., Blackshear, E. D., and Hyun, J. H. (1983). An Improved Continuous-Flow Condensation Nucleus Counter for Use in the Stratosphere. J. Aerosol Sci., 14:387–391, doi: 10.1016/0021-8502(83)90143-X.
  • Wimmer, D., Lehtipalo, K., Franchin, A., Kangasluoma, J., Kreissl, F., Kurten, A., Kupc, A., Metzger, A., Mikkila, J., Petaja, T., Riccobono, F., Vanhanen, J., Kulmala, M., and Curtius, J. (2013). Performance of Diethylene Glycol-Based Particle Counters in the Sub-3 nm Size Range. Atmos. Meas. Tech., 6:1793–1804, doi: 10.5194/amt-6-1793-2013.
  • Winkler, P. M., Steiner, G., Vrtala, A., Vehkamaki, H., Noppel, M., Lehtinen, K. E. J., Reischl, G. P., Wagner, P. E., and Kulmala, M. (2008). Heterogeneous Nucleation Experiments Bridging the Scale from Molecular Ion Clusters to Nanoparticles. Science, 319:1374–1377, doi: 10.1126/science.1149034.
  • Winkler, P. M., Vrtala, A., Steiner, G., Wimmer, D., Vehkamaki, H., Lehtinen, K. E. J., Reischl, G. P., Kulmala, M., and Wagner, P. E. (2012). Quantitative Characterization of Critical Nanoclusters Nucleated on Large Single Molecules. Phys. Rev. Lett., 108, Art. No. 085701, doi: 10.1103/Physrevlett.108.085701.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.