REFERENCES
- Bierhuizen , H. W. J. and Ferron , G. A. 1975 . Determination of the Diameter of Two Monodisperse Lattices by the Free Fall Method and the Length of Particle Arrays . J. Aerosol Sci. , 6 : 19 – 21 .
- Ehara , K. , Mulholland , G. W. and Hagwood , R. C. 2000 . Determination of Arbitrary Moments of Aerosol Size Distributions from Measurements with Differential Mobility Analyzer . Aerosol Sci. Technol. , 32 : 434 – 452 .
- Fuchs , N. A. 1973 . Latex Aerosols–Caution . J. Aerosol Sci. , 4 : 405 – 410 .
- Ishiguro , T. 1983 . Measurement of Aerosol Size Distribution and Collection Efficiency of HEPA Filter , M.S. Thesis Kanazawa , , Japan : Kanazawa University. .
- Iskandar , F. , Shimada , M. , Lenggoro , I. W. and Okuyama , K. Measurement of Spray-Dried Aerosol Particles by DMA/High-Sensitivity-Electrometer System . The 16th Symposium on Japan Aerosol Science and Technology . July 27–29 , Nagoya , Japan. pp. 87 – 89 . (in Japanese)
- Knutson , E. O. and Whitby , K. T. 1975a . Aerosol Classification by Electric Mobility: Apparatus, Theory and Applications . J. Aerosol Sci. , 6 : 443 – 451 .
- Knutson , E. O. and Whitby , K. T. 1975b . Accurate Measurement of Aerosol Electric Mobility Moments . J. Aerosol Sci. , 6 : 453 – 460 .
- Kousaka , Y. , Okuyama , K. , Shimada , M. and Ohshima , K. 1987 . A Precise Method to Determine the Diameter of Airborne Latex Particles . J. Aerosol Res. Japan , 2 : 200 – 206 . (in Japanese)
- Mulholland , G. W. , Bryner , N. P. and Croarkin , C. 1999 . Measurement of the 100 nm NIST SRM 1963 by Differential Mobility Assnalysis . Aerosol Sci. Technol. , 31 : 39 – 55 .
- Myojo , T. , Ikawa , S. , Sakae , H. and Kohyama , N. 2001 . A New Long DMA and Its Performance for Size-measurement of 1 μm Polystyrene Latex Particles . J. Air Cleaning Contamination Control , 39 : 168 – 175 . (in Japanese)
- Myojo , T. , Takaya , M. and Ono-Ogasawara , M. 2002 . DMA as a Gas Converter from Aerosol to “Argonsol” for Real-time Chemical Analysis Using ICP-MS . Aerosol Sci. Technol. , 36 : 76 – 83 .
- Okuyama , K. , Shimada , M. , Okita , A. , Otani , Y. and Cho , S. J. 1997 . Performance Evaluation of Cluster-DMA with Integrated Electrometer and Its Application to Ion Mobility Measurements . J. Aerosol Res. Japan , 13 : 83 – 93 .
- Otani , Y. , Emi , H. , Cho , S. J. and Okuyama , K. 1997 . Technique for Aerosol Flow Check in Differential Mobility Analyzer and Its Influence on Classification Performance . J. Chem. Eng. Japan , 30 : 1065 – 1069 .
- Porstendorfer , J. and Heyder , J. 1972 . Size Distributions of Latex Particles . J. Aerosol Sci. , 3 : 141 – 148 .
- Reischl , G. P. 1991 . Measurement of Ambient Aerosols by the Differential Mobility Analyzer Method: Concepts and Realization Criteria for the Size Range between 2 and 500 nm . Aerosol Sci. Technol. , 14 : 5 – 24 .
- Stolzenburg , M. , Kreisberg , N. and Hering , S. 1998 . Atmospheric Size Distributions Measured by Differential Mobility Optical Particle Size Spectrometry . Aerosol Sci. Technol. , 29 : 402 – 18 .
- Winklmayr , W. , Reischl , G. P. , Lindner , A. O. and Berner , A. 1991 . A New Electromobility Spectrometer for the Measurement of Aerosol Size Distribution in the Size Range from 1 to 1000 nm . J. Aerosol Sci. , 22 : 289 – 296 .