References
- Carter DR, Beaupré GS, Giori NJ, Helms JA. Mechanobiology of skeletal regeneration. Clin Orthop Relat Res (1976–2007). 1998;355:S41.
- Kenwright J, Goodship AE. Controlled mechanical stimulation in the treatment of tibial fractures. Clin Orthop Relat Res. 1989;(241):36–47.
- Uhrig BA, Li M-TA, Willett NJ, Guldberg RE. Models of composite bone and soft-tissue limb trauma. In: Ma PX, editor. Biomaterials and regenerative medicine. Cambridge:Cambridge University Press, 2013. 534–554. doi:https://doi.org/10.1017/CBO9780511997839.035
- Balogh ZJ, Reumann MK, Gruen RL, Mayer-Kuckuk P, Schuetz MA, Harris IA, Gabbe BJ, Bhandari M. Advances and future directions for management of trauma patients with musculoskeletal injuries. Lancet. 2012;380(9847):1109–1119. (London, England). doi:https://doi.org/10.1016/S0140-6736(12)60991-X.
- Barnes JA, Eid MA, Creager MA, Goodney PP. Epidemiology and risk of amputation in patients with diabetes mellitus and peripheral artery disease. Arterioscler Thromb Vasc Biol. 2020;40(8):1808–1817. doi:https://doi.org/10.1161/ATVBAHA.120.314595
- Murdoch G. Levels of amputation and limiting factors. Ann R Coll Surg Engl. 1967;40(4):204–216.
- Masquelet AC. Muscle reconstruction in reconstructive surgery: soft tissue repair and long bone reconstruction. Langenbeck’s Arch Surg. 2003;388(5):344–346. doi:https://doi.org/10.1007/s00423-003-0379-1
- Yazar S, Lin C-H, Wei F-C. One-stage reconstruction of composite bone and soft-tissue defects in traumatic lower extremities. Plast Reconstr Surg. 2004;114(6):1457–1466. doi:https://doi.org/10.1097/01.PRS.0000138811.88807.65
- Nauth A, McKee MD, Einhorn TA, Watson JT, Li R, Schemitsch EH. Managing bone defects. J Orthop Trauma. 2011;25(8):462–466. doi:https://doi.org/10.1097/BOT.0b013e318224caf0
- Hagan R, Kadzi J, Rahman G, Morna M. Patterns and indications of amputation in cape coast teaching hospital: a four year retrospective review. J West Afr Coll Surg. 2018;8(3):45–58.
- Mastinu E, Doguet P, Botquin Y, Håkansson B, Ortiz-Catalan M. Embedded system for prosthetic control using implanted neuromuscular interfaces accessed via an osseointegrated implant. IEEE Trans Biomed Circuits Syst. 2017;11(4):867–877. doi:https://doi.org/10.1109/TBCAS.2017.2694710
- Lynch JP, Wang W, Sun P, Burton A. unified in vivo/Ex vivo sensing architectures for monitoring osseointegrated prosthetics. University of Michigan Ann Arbor United States; 2018. https://apps.dtic.mil/sti/citations/AD1063783
- Burton AR, Sun P, Lynch JP. Bio-compatible wireless inductive thin-film strain sensor for monitoring the growth and strain response of bone in osseointegrated prostheses. Struct Health Monit. 2019Mar;13: 1475921719831452.https://doi.org/10.1177/1475921719831452.
- Koydemir HC, Ozcan A. Wearable and implantable sensors for biomedical applications. Ann Rev Anal Chem. 2018;11(1):127–146. doi:https://doi.org/10.1146/annurev-anchem-061417-125956
- Nelson BD, Karipott SS, Wang Y, Ong KG. Wireless technologies for implantable devices. Sensors. 2020;20(16):4604. doi:https://doi.org/10.3390/s20164604
- Ben Amar A, Kouki AB, Cao H. Power approaches for implantable medical devices. Sensors. 2015;15(11):28889–28914. (Basel, Switzerland). doi:https://doi.org/10.3390/s151128889.
- Thévenot DR, Toth K, Durst RA, Wilson GS. Electrochemical biosensors: recommended definitions and classification. Biosens Bioelectron. 2001;16(1–2):121–131. doi:https://doi.org/10.1016/S0956-5663(01)00115-4
- Honjol Y, Rajkumar VS, Parent-Harvey C, Selvasandran K, Kordlouie S, Comeau-Gauthier M, Harvey E, Merle G. Current view and prospect: implantable pressure sensors for health and surgical care. Med Devices Sens. 2020;3(3):e10068. doi:https://doi.org/10.1002/mds3.10068
- Karipott SS, Nelson BD, Guldberg RE, Ong KG. Clinical potential of implantable wireless sensors for orthopedic treatments. Expert Rev Med Devices. 2018;15(4):255–264. doi:https://doi.org/10.1080/17434440.2018.1454310
- Chiang C-C K, Lin -C-C, Ju M-S. An implantable capacitive pressure sensor for biomedical applications. Sens Actuators A Phys. 2007;134(2):382–388. doi:https://doi.org/10.1016/j.sna.2006.06.007
- Tan EL, Pereles BD, Horton B, Shao R, Zourob M, Ong KG. Implantable biosensors for real-time strain and pressure monitoring. Sensors. 2008;8(10):6396–6406. doi:https://doi.org/10.3390/s8106396
- Grieshaber D, MacKenzie R, Vörös J, Reimhult E. Electrochemical biosensors - sensor principles and architectures. Sensors. 2008;8(3):1400–1458. doi:https://doi.org/10.3390/s80314000
- Ferguson JE, Redish AD. 2011. Wireless communication with implanted medical devices using the conductive properties of the body. Expert Rev Med Devices. 8(4):427–433. doi:https://doi.org/10.1586/erd.11.16
- Polikov VS, Block ML, Fellous J-M, Hong J-S, Reichert WM. In vitro model of glial scarring around neuroelectrodes chronically implanted in the CNS. Biomaterials. 2006;27(31):5368–5376. doi:https://doi.org/10.1016/j.biomaterials.2006.06.018
- Turner JN, Shain W, Szarowski DH, Andersen M, Martins S, Isaacson M, Craighead H. Cerebral astrocyte response to micromachined silicon implants. Exp Neurol. 1999;156(1):33–49. doi:https://doi.org/10.1006/exnr.1998.6983
- Major MR, Wong VW, Nelson ER, Longaker MT, Gurtner GC. The foreign body response: at the interface of surgery and bioengineering. Plast Reconstr Surg. 2015;135(5):1489–1498. doi:https://doi.org/10.1097/PRS.0000000000001193
- Morais JM, Papadimitrakopoulos F, Burgess DJ. Biomaterials/tissue interactions: possible solutions to overcome foreign body response. AAPS J.2010;12(2):188–196. doi:https://doi.org/10.1208/s12248-010-9175-3
- Onuki Y, Bhardwaj U, Papadimitrakopoulos F, Burgess DJ. A review of the biocompatibility of implantable devices: current challenges to overcome foreign body response. J Diabetes Sci Technol. 2008;2(6):1003–1015. doi:https://doi.org/10.1177/193229680800200610
- Kim S-J, Lee D-S, Kim I-G, Sohn D-W, Park J-Y, Choi B-K, Kim S-W. Evaluation of the biocompatibility of a coating material for an implantable bladder volume sensor. Kaohsiung J Med Sci. 2012;28(3):123–129. doi:https://doi.org/10.1016/j.kjms.2011.10.016
- Koschwanez HE, Yap FY, Klitzman B, Reichert WM. In vitro and in vivo characterization of porous poly-L-lactic acid coatings for subcutaneously implanted glucose sensors. J Biomed Mater Res A. 2008;87(3):792–807. doi:https://doi.org/10.1002/jbm.a.31824
- Hickey T, Kreutzer D, Burgess DJ, Moussy F. In vivo evaluation of a dexamethasone/PLGA microsphere system designed to suppress the inflammatory tissue response to implantable medical devices. J Biomed Mater Res. 2002;61(2):180–187. doi:https://doi.org/10.1002/jbm.10016
- Tipnis NP, Burgess DJ. Sterilization of implantable polymer-based medical devices: a review. Int J Pharm. 2018;544(2):455–460. Advances in Drug Delivery Related Biosensors and Medical Devicesdoi:https://doi.org/10.1016/j.ijpharm.2017.12.003.
- Rydell NW. Forces acting on the femoral head-prosthesis: a study on strain gauge supplied prostheses in living persons. Acta Orthop Scand. 1966;37(sup88):1–132. doi:https://doi.org/10.3109/ort.1966.37.suppl-88.01
- Lanyon LE, Hampson WG, Goodship AE, Shah JS. Bone deformation recorded in vivo from strain gauges attached to the human tibial shaft. Acta Orthop Scand. 1975;46(2):256–268. doi:https://doi.org/10.3109/17453677508989216
- D’lima DD, Fregly BJ, Colwell CW. Implantable sensor technology: measuring bone and joint biomechanics of daily life in vivo. Arthritis Res Ther. 2013;15(1):203. doi:https://doi.org/10.1186/ar4138
- Ledet EH, Liddle B, Kradinova K, Harper S. Smart implants in orthopedic surgery, improving patient outcomes: a review. Innov Entrep Health. 2018;5:41–51. https://doi.org/10.2147/IEH.S133518.
- Ledet EH, D’lima D, Westerhoff P, Szivek JA, Wachs RA, Bergmann G. Implantable sensor technology: from research to clinical practice. J Am Acad Orthop Surg. 2012;20(6):383–392. doi:https://doi.org/10.5435/JAAOS-20-06-383
- Burny F, Donkerwolcke M, Bourgois R, Domb M, Saric O. Twenty years experience in fracture healing measurement with strain gauges. Orthopedics. 1984;7(12):1823–1826. doi:https://doi.org/10.3928/0147-7447-19841201-08
- Schneider E, Michel MC, Genge M, Zuber K, Ganz R, Perren SM. Loads acting in an intramedullary nail during fracture healing in the human femur. J Biomech. 2001;34(7):849–857. doi:https://doi.org/10.1016/s0021-9290(01)00037-9
- Klosterhoff BS, Vantucci CE, Kaiser J, Ong KG, Wood LB, Weiss JA, Guldberg RE, Willett NJ. Effects of osteogenic ambulatory mechanical stimulation on early stages of BMP-2 mediated bone repair. Bioengineering. 2020; http://biorxiv.org/lookup/doi/10.1101/2020.07.28.225870
- Klosterhoff BS, Kaiser J, Nelson BD, Karipott SS, Ruehle MA, Hollister SJ, Weiss JA, Ong KG, Willett NJ, Guldberg RE. Wireless sensor enables longitudinal monitoring of regenerative niche mechanics during rehabilitation that enhance bone repair. Bone. 2020;135:115311. https://doi.org/10.1016/j.bone.2020.115311.
- Klosterhoff BS, Vantucci CE, Kaiser J, Ong KG, Wood LB, Weiss JA, Guldberg RE, Willett NJ. Effects of osteogenic ambulatory mechanical stimulation on early stages of BMP-2 mediated bone repair. Connect Tissue Res. 2021Apr;5: 1–12.https://doi.org/10.1080/03008207.2021.1897582.
- Mavrogenis A, and Parvizi J. Biology of implant osseointegration. J Musculoskelet Neuronal Interact, Jun. 2009;9(2):61–71.
- Frossard L, Gow DL, Hagberg K, Cairns N, Contoyannis B, Gray S, Brånemark R, Pearcy M. Apparatus for monitoring load bearing rehabilitation exercises of a transfemoral amputee fitted with an osseointegrated fixation: a proof-of-concept study. Gait Posture. 2010;31(2):223–228. doi:https://doi.org/10.1016/j.gaitpost.2009.10.010
- Frossard L, Stevenson N, Smeathers J, Häggström E, Hagberg K, Sullivan J, Ewins D, Gow DL, Gray S, Brånemark R. Monitoring of the load regime applied on the osseointegrated fixation of a trans-femoral amputee: a tool for evidence-based practice. Prosthet Orthot Int. 2008;32(1):68–78. doi:https://doi.org/10.1080/03093640701676319
- Cole CP, Navarro RR. eDisc: the first artificial spinal disc with integral force-Sensing microelectronics. American Society of Mechanical Engineers Digital Collection. 2009;49–50. https://doi.org/10.1115/BioMed2007-38052.
- Cushner F, Schiller P, Gross J, Mueller J K, Hunter W. A total knee arthroplasty prosthesis capable of remote patient monitoring. Orthop Proceed. 2021;103-B(SUPP_9):18. doi:https://doi.org/10.1302/1358-992X.2021.9.018
- Mancipe Castro LM, Sequeira A, García AJ, Guldberg RE. Articular cartilage- and synoviocyte-Binding poly(ethylene glycol) nanocomposite microgels as intra-articular drug delivery vehicles for the treatment of osteoarthritis. ACS Biomater Sci Eng. 2020;6(9):5084–5095. doi:https://doi.org/10.1021/acsbiomaterials.0c00960
- Bernotiene E, Bagdonas E, Kirdaite G, Bernotas P, Kalvaityte U, Uzieliene I, Thudium CS, Hannula H, Lorite GS, Dvir-Ginzberg M et al. Emerging technologies and platforms for the immunodetection of multiple biochemical markers in osteoarthritis research and therapy. Front Med. 2020;7 [accessed 2021 May 30].https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7609858/.doi:https://doi.org/10.3389/fmed.2020.572977
- Afsarimanesh N, Mukhopadhyay SC, Kruger M. Molecularly imprinted polymer-based electrochemical biosensor for bone loss detection. IEEE Trans Biomed Eng.2018;65(6):1264–1271. doi:https://doi.org/10.1109/TBME.2017.2744667
- Tadano S, Takeda R, Sasaki K, Fujisawa T, Tohyama H. Gait characterization for osteoarthritis patients using wearable gait sensors (H-Gait systems). J Biomech. 2016;49(5):684–690. doi:https://doi.org/10.1016/j.jbiomech.2016.01.017
- Ismailidis P, Nüesch C, Kaufmann M, Clauss M, Pagenstert G, Eckardt A, Ilchmann T, Mündermann A. Measuring gait kinematics in patients with severe hip osteoarthritis using wearable sensors. Gait Posture. 2020;81:49–55. https://doi.org/10.1016/j.gaitpost.2020.07.004.
- Kobsar D, Osis ST, Boyd JE, Hettinga BA, Ferber R. Wearable sensors to predict improvement following an exercise intervention in patients with knee osteoarthritis. J Neuroeng Rehabil. 2017;14(1):94. doi:https://doi.org/10.1186/s12984-017-0309-z
- Revzin A, Maverakis E, Chang H-C. Biosensors for immune cell analysis—A perspective. Biomicrofluidics. 2012;6(2):021301–021301–13. doi:https://doi.org/10.1063/1.4706845
- Alonso B, Bravo B, Mediavilla L, Gortazar AR, Forriol F, Vaquero J, Guisasola MC. Osteoarthritis-related biomarkers profile in chronic anterior cruciate ligament injured knee. Knee. 2020;27(1):51–60. doi:https://doi.org/10.1016/j.knee.2019.12.007
- Clausen I, Glott T. Development of clinically relevant implantable pressure sensors: perspectives and challenges. Sensors. 2014;14(9):17686–17702. doi:https://doi.org/10.3390/s140917686. (Basel, Switzerland).
- Borchani W, Aono K, Lajnef N, Chakrabartty S. Monitoring of postoperative bone healing using smart trauma-fixation device with integrated self-powered piezo-floating-gate sensors. IEEE Trans Biomed Eng. 2016;63(7):1463–1472. doi:https://doi.org/10.1109/TBME.2015.2496237
- Bullen RA, Arnot TC, Lakeman JB, Walsh FC. Biofuel cells and their development. Biosens Bioelectron. 2006;21(11):2015–2045. doi:https://doi.org/10.1016/j.bios.2006.01.030
- Nguyen MQ, Hughes Z, Woods P, Seo Y-S, Rao S, Chiao J-C. Field distribution models of spiral coil for misalignment analysis of wireless power transfer systems. IEEE Trans Microw Theory Tech. 2014;62(4):920–930.doi:https://doi.org/10.1109/TMTT.2014.2302738.
- Pereles BD, DeRouin AJ, Ong KG. Partially loaded magnetoelastic sensors with customizable sensitivities for large force measurements. IEEE Sens J. 2015;15(1):591–597. doi:https://doi.org/10.1109/JSEN.2014.2348500
- Ernst M, Richards RG, Windolf M. Smart implants in fracture care – only buzzword or real opportunity? Injury. 2021;52:S101–S105. https://doi.org/10.1016/j.injury.2020.09.026.
- Dinis H, Mendes PM. A comprehensive review of powering methods used in state-of-the-art miniaturized implantable electronic devices. Biosens Bioelectron. 2021;172:112781. https://doi.org/10.1016/j.bios.2020.112781.
- Lee S, Shi Q, Lee C. From flexible electronics technology in the era of IoT and artificial intelligence toward future implanted body sensor networks. APL Materials. 2019;7(3):031302. doi:https://doi.org/10.1063/1.5063498
- Phan H-P. Implanted flexible electronics: set device lifetime with smart nanomaterials. Micromachines. 2021;12(2):157. doi:https://doi.org/10.3390/mi12020157
- Bashir R. BioMEMS: state-of-the-art in detection, opportunities and prospects. Adv Drug Deliv Rev. 2004;56(11):1565–1586. doi:https://doi.org/10.1016/j.addr.2004.03.002
- Gilleo K. MEMS in medicine. Circuit Assembly. 2005;16(8):32–33.
- Ashammakhi N, Hernandez AL, Unluturk BD, Quintero SA, de Barros NR, Hoque Apu E, Bin Shams A, Ostrovidov S, Li J, Contag C et al. Biodegradable implantable sensors: materials design, fabrication, and applications. Adv Funct Mater. 2021;31(49):2104149. doi:https://doi.org/10.1002/adfm.202104149.
- Luo M, Martinez AW, Song C, Herrault F, Allen MG. A microfabricated wireless rf pressure sensor made completely of biodegradable materials. J Microelectromech Syst. 2014;23(1):4–13. doi:https://doi.org/10.1109/JMEMS.2013.2290111
- Tsang M, Armutlulu A, Martinez AW, Allen SA, Allen M. Biodegradable magnesium/iron batteries with polycaprolactone encapsulation: a microfabricated power source for transient implantable devices. Microsyst Nanoeng. 2015;1(1). doi:https://doi.org/10.1038/MICRONANO.2015.24
- Yin L, Huang X, Xu H, Zhang Y, Lam J, Cheng J, Rogers JA. Materials, designs, and operational characteristics for fully biodegradable primary batteries. Adv Mater (Deerfield Beach, Fla). 2014;26(23):3879–3884. doi:https://doi.org/10.1002/adma.201306304
- Kim D-H, Viventi J, Amsden JJ, Xiao J, Vigeland L, Kim Y-S, Blanco JA, Panilaitis B, Frechette ES, Contreras D et al. Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics. Nat Mater. 2010;9(6):511–517. doi:https://doi.org/10.1038/nmat2745.
- Pizzolato C, Lloyd DG, Barrett RS, Cook JL, Zheng MH, Besier TF, Saxby DJ. bioinspired technologies to connect musculoskeletal mechanobiology to the person for training and rehabilitation. Front Comput Neurosci. 2017;11:96. https://doi.org/10.3389/fncom.2017.00096.
- Krouskop TA, Dougherty DR, Vinson FS. A pulsed Doppler ultrasonic system for making noninvasive measurements of the mechanical properties of soft tissue. J Rehab Res Dev. 1987;24(2):1–8.
- Rando TA, Ambrosio F. Regenerative rehabilitation: applied biophysics meets stem cell therapeutics. Cell Stem Cell. 2018;22(3):306–309. doi:https://doi.org/10.1016/j.stem.2018.02.003
- Boutry CM, Kaizawa Y, Schroeder BC, Chortos A, Legrand A, Wang Z, Chang J, Fox P, Bao Z. A stretchable and biodegradable strain and pressure sensor for orthopaedic application. Nature Electronics. 2018;1(5):314–321. doi:https://doi.org/10.1038/s41928-018-0071-7
- Ashley EA, Butte AJ, Wheeler MT, Chen R, Klein TE, Dewey FE, Dudley JT, Ormond KE, Pavlovic A, Hudgins L et al. Clinical evaluation incorporating a personal genome. Lancet. 2010;375(9725):1525–1535. doi:https://doi.org/10.1016/S0140-6736(10)60452-7.
- Overmann AL, Forsberg JA. The state of the art of osseointegration for limb prosthesis. Biomed Eng Lett. 2020;10(1):5–16. doi:https://doi.org/10.1007/s13534-019-00133-9
- Shah JP, Phillips TM, Danoff JV, Gerber LH. An in vivo microanalytical technique for measuring the local biochemical milieu of human skeletal muscle. J Appl Physiol. 2005;99(5):1977–1984. doi:https://doi.org/10.1152/japplphysiol.00419.2005
- Gerdle B, Ghafouri B, Ernberg M, Larsson B. Chronic musculoskeletal pain: review of mechanisms and biochemical biomarkers as assessed by the microdialysis technique. J Pain Res. 2014;7:313–326. https://doi.org/10.2147/JPR.S59144.
- Nyein HYY, Bariya M, Tran B, Ahn CH, Brown BJ, Ji W, Davis N, Javey A. A wearable patch for continuous analysis of thermoregulatory sweat at rest. Nat Commun. 2021;12(1):1823. doi:https://doi.org/10.1038/s41467-021-22109-z
- Nyein HYY, Bariya M, Kivimäki L, Uusitalo S, Liaw TS, Jansson E, Ahn CH, Hangasky JA, Zhao J, Lin Y et al. Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat. Sci Adv. 2019;5(8):eaaw9906. doi:https://doi.org/10.1126/sciadv.aaw9906.
- Peake JM, Kerr G, Sullivan JP. A critical review of consumer wearables, mobile applications, and equipment for providing biofeedback, monitoring stress, and sleep in physically active populations. Front Physiol. 2018;9: [accessed 2021 Jun 18] https://www.frontiersin.org/articles/10.3389/fphys.2018.00743/full?utm_source=S-TWT&utm_medium=SNET&utm_campaign=ECO_FPHYS_XXXXXXXX_auto-dlvrit.doi:https://doi.org/10.3389/fphys.2018.00743
- Karipott SS, Veetil PM, Nelson BD, Guldberg RE, Ong KG. An embedded wireless temperature sensor for orthopedic implants. IEEE Sens J. 2018;18(3):1265–1272. doi:https://doi.org/10.1109/JSEN.2017.2780226
- Zhu R. Real-time monitoring of the athlete’s musculoskeletal health based on an embedded processor. Microprocess Microsyst. 2021;81:103742. https://doi.org/10.1016/j.micpro.2020.103742.
- Klosterhoff BS, Ghee Ong K, Krishnan L, Hetzendorfer KM, Chang Y-H, Allen MG, Guldberg RE, Willett NJ. Wireless implantable sensor for noninvasive, longitudinal quantification of axial strain across rodent long bone defects. J Biomech Eng. 2017;139(11):111004. doi:https://doi.org/10.1115/1.4037937
- Klosterhoff BS, Kaiser J, Nelson BD, Karipott SS, Ruehle MA, Hollister SJ, Weiss JA, Ong KG, Willett NJ, Guldberg RE. Real-time monitoring of mechanical cues in the regenerative niche reveal dynamic strain magnitudes that enhance bone repair. bioRxiv. Jun 6 2019;663278. doi:https://doi.org/10.1101/663278.
- Yang JC, Mun J, Kwon SY, Park S, Bao Z, Park S. Electronic skin: recent progress and future prospects for skin-attachable devices for health monitoring, robotics, and prosthetics. Adv Mater. 2019;31(48):1904765. doi:https://doi.org/10.1002/adma.201904765
- Armitage L, Rajan G, Kark L, Simmons A, Prusty BG. Simultaneous measurement of normal and shear stress using fiber Bragg grating sensors in prosthetic applications. IEEE Sens J. 2019;19(17):7383–7390. doi:https://doi.org/10.1109/JSEN.2019.2914702
- Sanders JE, Zachariah SG, Baker AB, Greve JM, Clinton C. Effects of changes in cadence, prosthetic componentry, and time on interface pressures and shear stresses of three trans-tibial amputees. Clini Biomech. 2000;15(9):684–694. doi:https://doi.org/10.1016/S0268-0033(00)00026-7
- Laszczak P, Jiang L, Bader DL, Moser D, Zahedi S. Development and validation of a 3D-printed interfacial stress sensor for prosthetic applications. Med Eng Phys. 2015;37(1):132–137.doi:https://doi.org/10.1016/j.medengphy.2014.10.002
- Laszczak P, McGrath M, Tang J, Gao J, Jiang L, Bader DL, Moser D, Zahedi S. A pressure and shear sensor system for stress measurement at lower limb residuum/socket interface. Med Eng Phys. 2016;38(7):695–700. doi:https://doi.org/10.1016/j.medengphy.2016.04.007
- Longo UG, Candela V, Berton A, De Salvatore S, Fioravanti S, Giannone L, Marchetti A, De Marinis MG, Denaro V. Biosensors for detection of biochemical markers relevant to osteoarthritis. Biosensors. 2021;11(2):31. doi:https://doi.org/10.3390/bios11020031
- Song SY, Han YD, Hong SY, Kim K, Yang SS, Min B-H, Yoon HC. Chip-based cartilage oligomeric matrix protein detection in serum and synovial fluid for osteoarthritis diagnosis. Anal Biochem. 2012;420(2):139–146. doi:https://doi.org/10.1016/j.ab.2011.09.012
- Huang Y-C, Chiang C-Y, C-H L, Chang T-C, Chiang C-S, Chau L-K, Huang K-W, C-w W, Wang S-C, Lyu S-R. Quantification of tumor necrosis factor-α and matrix metalloproteinases-3 in synovial fluid by a fiber-optic particle plasmon resonance sensor. Analyst. 2013;138(16):4599–4606. doi:https://doi.org/10.1039/c3an00276d
- Chiang C-Y, Hsieh M-L, Huang K-W, Chau L-K, Chang C-M, Lyu S-R. Fiber-optic particle plasmon resonance sensor for detection of interleukin-1β in synovial fluids. Biosens Bioelectron. 2010;26(3):1036–1042. doi:https://doi.org/10.1016/j.bios.2010.08.047