- PICKAP, J. C., SHAW, G. W., and CLAREMONT, D. J., 1989, In vivo molecular sensing in diabetes mellitus: an implantable glucose sensor with direct electron transfer. Diabetologia, 32, 213-217.
- FISHER, M. E., 1991, A semiclosed-loop algorithm for the control of blood glucose levels in diabetics. IEEE Transactions on Biomedical Engineering, 38, 57-61.
- MARTIN, R. W., HILL., H. F., YEE, H. C., SAEGER, L. C., WALTER, M. H., and CHAPMAN, C. R., 1987, An open-loop computerbased drug infusion system. IEEE Transactions on Biomedical Engineering, 34, 642-648.
- COBELLI, C., and MARI, A., 1985, Control of diabetes with artificial systems for insulin delivery-algorithm independent limitations revealed by a modeling study. IEEE Transactions on Biomedical Engineering, 32, 840-845.
- BENMAKROHA, Y., ZHANG S., and ROLFE, P., 1995, Sensors. Medical & Biological Engineering & Computing, 33, 811 -821.
- MENDELSON, Y., CLERMONT, A. C., PEURA, R. A., and LIN, B. C., 1990, Blood glucose measurement by multiple attenuated total reflection and infrared absorption spectroscopy. IEEE Transactions m Biomedical Engineering, 37, 458-465.
- COTE, G. L., Fox, M. D., and NORTHROP, R. B., 1992, Noninvasive optical polarimetric glucose sensing using a true phase measurement technique. IEEE Transactions on Biomedical Engineering, 39, 752-755.
- VALDESPERZGASGA, F., and COVINGTON, A. K., 1987, Multisensor operation of ion-selective field-effect transistors in the constant current mode. Sensors and Actuators, 4, 235238.
- CASS, A. E. G., 1990, Biosensors: a Practical Approach (Oxford: Oxford University Press).
- TURNER, A. P., KARUBE, I., and WILSON, G. S., 1989, Biosensors-Fundamentals and Applications (Oxford: Oxford Science Publications).
- WANG,J., Wu, L. H., and SANCHEZ,J., 1990, Mixed ferrocene glucose-oxidase carbon paste electrode for amperometric determination of glucose. Analytical Chemistry Act, 228, 251-257.
- DONG, S. J., WANG, B. X., and LuI, B. F., 1992, Amperometric glucose sensor with ferrocene as an electrontransfer mediator. Biosensors & Bioelectronics, 7, 215-222.
- FOGT, E. J., DODD, L.M.,JERMING, E.M., and CLEMENTS, A.H., 1978, Development and evaluation of a glucose analyzer for glucose-controlled insulin infusion system. Clinical Chemistry, 24, 1366-1372.
- CHEN, C. Y., TAMIYA, E., ISHIHARA, K., KASUGI, Y., Su. Y., NAKADAYASHI, N., and KARUBE, I., 1992, A biocompatibility needle-type glucose based on platinum electroplated carbon electrode. Applied Biochemistry and Biotechnology, 36, 211-226.
- DESAI, M., GHOSH, S., NGRUMP, P., BENMAKROHA, Y., and VADGAMA, P., 1993, Internal membranes and laminates for adaptation of amperometric enzyme electrodes to direct biofluid analysis, Scandinavian Journal of Clinical Laboratory Investigation, 53, 53-60.
- KOOCHAKI, M. R., HIGSON, S. P. J., and VADGAMA, P., 1993, The diffusion limited oxidase based glucose enzyme electrode; relation between covering membrane permeability and substrate response. Analytical Chemistry Acta, 76, 261-268.
- TANG, L. X., KOOCHAKI, Z. B., and VAGGAMA, P., 1990, Composite liquid membrane for enzyme electrode construction. Analytical Chemistry Acta, 232, 357-365.
- WEISE, D. A. BOWEN, T. P., and KOST, G. J., 1989, Enzyme electrode for glucose measurement in whole-blood with a critical care profiling instrument. Clinical Chemistry, 35, 1098-1099.
- LERNER, H., SOELDNER, J.S., COLTON, C. K., and GINKR, J., 1982, Measurement of glucose concentration in the presence of coreactants with a platinum electrode. Diabetes Care, 5, 229-237.
- MAJ, S., and PAWELSKI, S., 1985, Standards and clinical interpolation of diagnostical investigations in internal medicine. PZWL, 923-927.
- FLOYD, T. L., 1992, Electronic Devices (New York: McGrawHiIl), pp. 677-680.
- KULKA, Z., LIBURA, A., and NADACHOWSKI, M., 1987, Analogto-digital and digital-to-analog converters. WKL, 300- 307, Warsaw.
- MULLEN, W. H., KEEDY, F. H., CHURCHOUSE, S. J., and VADGAMA, P., 1986, Glucose enzyme electrode with extended linearity. Analitica Chimica Acta, 183, 59-66.
- METTING VAN RIJIN, A. C., PAPER A., and GRINMBERGEN, C. A., 1994, Amplifiers for bioelectric events; a design with a minimal number of parts. Medical and Biological Engineering and Computing, 32, 305-310.
- CHEN, W. K., 1986, Passive and Active Filters; Theory and Implementations (New York: John Wiley & Sons), pp. 194220.
An accurate amperometric glucose sensor based glucometer with eliminated cross-sensitivity
Reprints and Corporate Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
To request a reprint or corporate permissions for this article, please click on the relevant link below:
Academic Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
Obtain permissions instantly via Rightslink by clicking on the button below:
If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.