241
Views
44
CrossRef citations to date
0
Altmetric
Research Article

Non-invasive glycaemia blood measurements by electromagnetic sensor: Study in static and dynamic blood circulation

, , , , , & show all
Pages 22-26 | Published online: 04 Aug 2009

References

  • The Diabetes Control and Complications Trial Research Group, 1993, The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. New England Journal of Medicine, 329, 977–986.
  • Updike, S. J., Shults, M. C., Gilligan, B. J., and Rhodes, R. K., 2000, A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration. Diabetes Care, 23, 208–214.
  • Critchley, L. A., Calcroft, R. M., Tan, P. Y., Kew, J., and Critchley, J. A., 2000, The effect of lung injury and excessive lung fluid, on impedance cardiac output measurements, in the critically ill. Intensive Care Medicine, 26, 679–685.
  • Young, J. D., and MCQuillan, P., 1993, Comparison of thoracic electrical bio impedance and thermo dilution for the measurement of cardiac index in patients with severe sepsis. British Journal of Anaesthesia, 70, 58— 62.
  • Hirschl, M. M., Kittler, H., Woisetschlager, C., Siostrzonek, P., Staudinger, T., Kofler, J., Oschatz, E., Bur, A., Gwechenberger, M., and Laggner, A. N., 2000, Simultaneous comparison of thoracic bio-impedance and arterial pulse waveform-derived cardiac output with thermo-dilution measurement. Critical Care Medicine, 28, 1798–1802.
  • Summers, R. L., Kolb, J. C., Woodward, L. H., and Galli, R. L., 1999, Diagnostic uses for thoracic electrical bio-impedance in the emergency department: clinical case series. European Journal of Emergency Medicine, 6, 193–199.
  • Meyerhoff, C., Bischof, F., Sternberg, F., Zier, E., and Pfeiffer, F., 1995, On line continuous monitoring of subcutaneous tissue glucose monitoring system. Diabetes Medicine, 12, 173— 176.
  • Tiszen, K. L., Burton, S. F., Dornon, T. L., Matthews, D. R., and McMurray, J. R., 1996, Evaluation of a second- generation electrochemi-cal blood glucose monitoring system. Diabetes Medicine, 21, 585 — 590.
  • Tamada, J. A., Bohannon, N. J. V. and Potts, R. O., 1995, Measurement of glucose in diabetic subjects using non-invasive transdermal extraction. Natural Medicine, 1, 1198— 1201.
  • Glikfield, P., Hinz, R. S., Guy, R. H., 1996, Non-invasive sampling of biological fluid by iontophoresis. Pharmaceutical Research, 12, 1322 — 1326.
  • Kohl, M., Cope, M., Essenpreis, M., and Bocker, D., 1994, Influence of glucose-concentration on light-scattering in tissue-simulating phantoms. Optics Letters, 19, 2170–2172.
  • Kohl, M., Essenpreis, M., and Cope, M., 1995, The influence of glucose concentration upon the transport of light in tissue-simulating phantoms. Physics in Medicine and Biology, 40, 1267 — 1287.
  • Kohl, M., Essenpreis, M., Bocker, D., and Cope, M., 1995, Glucose induced changes in scattering and light transport in tissue-simulating phantoms. Proceedings of SPIE, 2389, 780–788.
  • Maier, J. S., Walker, S. A., Fantini, S., Franceschini, M. A., and Gratton, E., 1995, Possible correlation between blood glucose concentration and reduced scattering coefficient of tissues in the near-infrared. Optics Letters, 19, 2062–2064.
  • Small, G. W., Arnold, M., and Marquardt, L., 1993, Strategies for coupling digital filtering with partial least-squares regression: applica-tion to the determination of glucose in plasma by Fourier transform near-infrared spectroscopy. Analytical Chemistry, 65, 3279–3289.
  • Alavi, S. M., Gourzi, M., Rouane, A., and Nadi, M., 2001, An original method for non-invasive glucose measurement: preliminary results. Engineering in Medicine and Biology Society, October 2001. Proceedings of the 23rd Annual International Conference of the IEEE, 4, pp. 25–28, 3318–3320.
  • Gourzi, M., Rouane, A., Guelaz, R., and Nadi, M., 2003, New biosensor for non-invasive glucose concentration measurement. The second IEEE International Conference on Sensors, October 2003, Toronto, Canada, 4, 480–482.
  • Gourzi, M., Rouane, A., Nadi, M., 2004, Un capteur electromagnétique pour la mesure non-invasive de la glycemie. Troisieme edition du colloque interdisciplinaire en instrumentation, Nouvelles methodes: C2I, 2, 395–402.
  • Moran, G. R., Jeffrey, K. R., Thomas, J. M., and Stevens, J. R., 2000, A dielectric analysis of liquid and glassy solid glucose/water solutions. Carbohydrate Research, 6, 573 — 584.
  • Gourzi, M., Rouane, A., Guelaz, R., Nadi, M., and Jaspard, F., 2003, Study of a new electromagnetic sensor for glycaemia measurement: in vitro results on pig blood. Journal of Medical Engineering & Technology, 627, 276–281.
  • Marchal, C., Nadi, M., Tosser, A. J., Roussey, C., and Gaulard, M. L., 1989, Dielectric properties of gelatine phantoms used for simulations of biological tissues between 10 and 50 MHz. International Journal of Hyperthermia, 5, 725–732.
  • Tamada, J. A., Bohannon, N. J. V, and Potts, R. O., 1995, Measurement of glucose in diabetic subjects using non-invasive transdermal extraction. Natural Medicine Abstract-MEDLINE, Ab-stract-EMBASE, 1198–1201.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.