Effect of geometric parameters in the design of customized hip implants

&
Pages 429-436 | Received 22 Nov 2016, Accepted 24 Apr 2017, Published online: 06 Jun 2017

References

  • Gotze C, Steens W, Vieth V, et al. Primary stability in cementless femoral stems: custom-made versus conventional femoral prosthesis. Clin Biomech. 2002;17:267–273.
  • Sebastien M, Fridtjov I, Arild A. A quantitative and qualitative analysis of bone remodeling around custom uncemented femoral stems: a five-year DEXA follow-up. Clin Biomech. 2005;20:277–282.
  • Yongtae J, Kuiwoon C. Design of patient-specific hip implants based on the 3D geometry of the human femur. Adv Eng Softw. 2010;41:537–547.
  • Latham B, Goswami T. Effect of geometric parameters in the design of hip implants paper IV. Mater Des. 2004;25:715–722.
  • Buford A, Goswami T. Review of wear mechanisms in hip implants. Paper I – general. Mater Des. 2004;5:385–393.
  • Griza S, dos Santos SV, Ueki MM, et al. Case study and analysis of a fatigue failure in a THA stem. Eng Fail Anal. 2013;28:166–175.
  • Schmalzreid TP, Szuszczewicz ES, Northfield MR, et al. Quantitative assessment of walking activity after total hip or knee replacement. J Bone Joint Surg Am. 1998;80:54–59.
  • Silva M, Shepherd EF, Jackson WO, et al. Average patient walking activity approaches 2 million cycles per year: pedometers under-record walking activity. J Arthroplasty. 2002;17:693–697.
  • Crowninshield RD, Brand RA, Johnston RC, et al. An analysis of femoral component stem design in total hip arthroplasty. J Bone Joint Surg Am. 1980;62:68–78.
  • Baleani M, Viceconti M, Muccini R, et al. Endurance verification of custom-made hip prostheses. Int J Fatigue. 2000;22:865–871.
  • Dar FH, Meakin JR, Aspden RM. Statistical methods in finite element analysis. J Biomech. 2002;35:1155–1161.
  • Taguchi G. Introduction to quality engineering. Tokyo: Asian Productivity Organization; 1990.
  • Zienkiewicz OC, Taylor RL. The finite element method. Vol. 1, 6th ed. Oxford: Butterworth-Heinemann; 2005.
  • ISO 7206/3. Determination of endurance properties of stemmed femoral components without application of torsion, Implants for surgery – partial and total hip joint prostheses. Geneva (CH): International Standards Organisation; 1987.
  • ISO 7206/4. Determination of endurance properties of stemmed femoral components with application of torsion, Implants for surgery – partial and total hip joint prostheses. Geneva (CH): International Standards Organisation; 2002.
  • Bergmann G, Graichen F, Rohlmann A, et al. Realistic loads for testing hip implants. Biomed Mater Eng. 2010;20:65–75.
  • Bergmann G, Graichen F, Rohlmann A. Hip joint loading during walking and running, measured in two patients. J Biomech. 1993;26:969–990.
  • Joshi MG, Advani SG, Miller F, et al. Analysis of a femoral hip prosthesis designed to reduce stress shielding. J Biomech. 2000;33:1655–1662.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.