References
- Gotze C, Steens W, Vieth V, et al. Primary stability in cementless femoral stems: custom-made versus conventional femoral prosthesis. Clin Biomech. 2002;17:267–273.
- Sebastien M, Fridtjov I, Arild A. A quantitative and qualitative analysis of bone remodeling around custom uncemented femoral stems: a five-year DEXA follow-up. Clin Biomech. 2005;20:277–282.
- Yongtae J, Kuiwoon C. Design of patient-specific hip implants based on the 3D geometry of the human femur. Adv Eng Softw. 2010;41:537–547.
- Latham B, Goswami T. Effect of geometric parameters in the design of hip implants paper IV. Mater Des. 2004;25:715–722.
- Buford A, Goswami T. Review of wear mechanisms in hip implants. Paper I – general. Mater Des. 2004;5:385–393.
- Griza S, dos Santos SV, Ueki MM, et al. Case study and analysis of a fatigue failure in a THA stem. Eng Fail Anal. 2013;28:166–175.
- Schmalzreid TP, Szuszczewicz ES, Northfield MR, et al. Quantitative assessment of walking activity after total hip or knee replacement. J Bone Joint Surg Am. 1998;80:54–59.
- Silva M, Shepherd EF, Jackson WO, et al. Average patient walking activity approaches 2 million cycles per year: pedometers under-record walking activity. J Arthroplasty. 2002;17:693–697.
- Crowninshield RD, Brand RA, Johnston RC, et al. An analysis of femoral component stem design in total hip arthroplasty. J Bone Joint Surg Am. 1980;62:68–78.
- Baleani M, Viceconti M, Muccini R, et al. Endurance verification of custom-made hip prostheses. Int J Fatigue. 2000;22:865–871.
- Dar FH, Meakin JR, Aspden RM. Statistical methods in finite element analysis. J Biomech. 2002;35:1155–1161.
- Taguchi G. Introduction to quality engineering. Tokyo: Asian Productivity Organization; 1990.
- Zienkiewicz OC, Taylor RL. The finite element method. Vol. 1, 6th ed. Oxford: Butterworth-Heinemann; 2005.
- ISO 7206/3. Determination of endurance properties of stemmed femoral components without application of torsion, Implants for surgery – partial and total hip joint prostheses. Geneva (CH): International Standards Organisation; 1987.
- ISO 7206/4. Determination of endurance properties of stemmed femoral components with application of torsion, Implants for surgery – partial and total hip joint prostheses. Geneva (CH): International Standards Organisation; 2002.
- Bergmann G, Graichen F, Rohlmann A, et al. Realistic loads for testing hip implants. Biomed Mater Eng. 2010;20:65–75.
- Bergmann G, Graichen F, Rohlmann A. Hip joint loading during walking and running, measured in two patients. J Biomech. 1993;26:969–990.
- Joshi MG, Advani SG, Miller F, et al. Analysis of a femoral hip prosthesis designed to reduce stress shielding. J Biomech. 2000;33:1655–1662.