A simple encoding method for Sigma-Delta ADC based biopotential acquisition systems

ORCID Icon & ORCID Icon
Pages 546-552 | Received 02 Jun 2017, Accepted 08 Aug 2017, Published online: 28 Sep 2017

References

  • Curtin M. Sigma-delta techniques reduce hardware count and power consumption in biomedical analog front end. Analog Dialog. 1994;28:6–7.
  • McKee J, Evans N, Wallace D. Sigma-delta analogue-to-digital converters for ECG signal acquisition. Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, vol. 1; 1996. p. 19–20.
  • Vanhatalo S, Voipio J, Kaila K. Full-band EEG (FbEEG): an emerging standard in electroencephalography. Clin Neurophysiol. 2005;116:1–8.
  • Usakli AB, Gencer NG. USB-based 256-channel electroencephalographic data acquisition system for electrical source imaging of the human brain. Instrument Sci Technol. 2007;35:255–273.
  • Weyer S, Menden T, Leicht L, et al. Development of a wearable multi-frequency impedance cardiography device. J Med Eng Technol. 2015;39:131–137.
  • Antonio J, Gnecchi G, Téllez C. Following the path towards intelligently connected devices for on-line, real-time cardiac arrhythmia detection and classification. IEEE International Autumn Meeting on Power, Electronics and Computing; 2016. p. 0–4.
  • MettingVanRijn AC, Kuiper AP, Linnenbank AC, et al. Patient isolation in multichannel bioelectric recordings by digital transmission through a single optical fiber. IEEE Trans Biomed Eng. 1993;40:302–308.
  • Neuroelectrics. Neuroelectrics User Manual V2.0; 2017. Available from: http://www.neuroelectrics.com/download/NE_UM_Part01_Enobio.pdf
  • Chua E, Fang WC. Mixed bio-signal lossless data compressor for portable brain-heart monitoring systems. IEEE Trans Consumer Electron. 2011;57:267–273.
  • Chanasabaeng P, Charoen B, Paphangkorakit J. Lossless compression of electromyographic signal. 5th 2012 Biomedical Engineering International Conference, BMEiCON; 2012.
  • Cho GY, Lee GY, Lee TR. Efficient real-time lossless EMG data transmission to monitor pre-term delivery in a medical information system. Appl Sci. 2017;7:366.
  • Brinkmann BH, Bower MR, Stengel KA, et al. Large-scale electrophysiology: acquisition, compression, encryption, and storage of big data. J Neurosci Methods. 2009;180:185–192.
  • Mukhopadhyay SK, Mitra S, Mitra M. A lossless ECG data compression technique using ASCII character encoding. Comput Electr Eng. 2011;37:486–497.
  • Mukhopadhyay SK, Mitra S, Mitra M. A combined application of lossless and lossy compression in ECG processing and transmission via GSM-based SMS. J Med Eng Technol. 2015;39:105–122.
  • Chang CT, Nien CM, Rieger R. Microcontroller implementation of low-power compression for wearable biosignal transmitter. 2016 International Symposium on VLSI Design, Automation and Test, VLSI-DAT; 2016. p. 2–5.
  • Chidean MI, Barquero-Perez O, Zhang Q, et al. High diagnostic quality ECG compression and CS signal reconstruction in body sensor networks. 2016 IEEE International Conference on Acoustics, Speech, and Signal Processing; Mar. IEEE; 2016. p. 6255–6259.
  • Scheer HJ, Sander T, Trahms L. The influence of amplifier, interface and biological noise on signal quality in high-resolution EEG recordings. Physiol Meas. 2006;27:109–117.
  • Linnenbank A, Metting Van Rijn AC, Grimbergen C, et al. Choosing the resolution in AD conversion of biomedical signals. Proceedings of the XXIInd International Congress on Electrocardiology; Nijmegen, The Netherlands; 1995. p. 198–199.
  • AAMI. Diagnostic electrocardiographic devices. ANSI/AAMI EC11:1991/(R)2001/(R)2007; 2007.
  • Chang GC, Lin YD. An efficient lossless ECG compression method using Delta coding and optimal selective Huffman coding. 6th World Congress of Biomechanics (WCB 2010); 2010 Aug 1–6; Singapore. In Conjunction with 14th International Conference on Biomedical Engineering (ICBME) and 5th Asia Pacific Conference on Biomechanics (APBiomech). Berlin, Heidelberg: Springer; 2010. p. 1327–1330.
  • Google. Protocol buffer. Developers guide: encoding; 2014. Available from: https://developers.google.com/protocol-buffers/docs/encoding#varints
  • Guerrero FN, Spinelli EM, Haberman MA. Analysis and simple circuit design of double differential EMG active electrode. IEEE Trans Biomed Circuits Syst. 2016;10:787–795.
  • Guerrero FN, Spinelli E. High gain driven right leg circuit for dry electrode systems. Med Eng Phys. 2017;39:117–122.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.