183
Views
13
CrossRef citations to date
0
Altmetric
Original Articles

A statistically adaptive sampling policy to the Hotelling's T2 control chart: Markov chain approach

, , &
Pages 3919-3929 | Received 19 Nov 2013, Accepted 31 Mar 2014, Published online: 16 May 2016

References

  • Amin, R.W., Hemasinha, R. (1993). The switching behavior of X-bar charts with variable sampling intervals. Commun. Stat. – Theory Methods 22:2081–2102.
  • Chen, Y.K. (2007). Adaptive sampling enhancement for Hotelling's T2 charts. Eur. J. Oper. Res. 178:841–857.
  • Chen, Y.K., Hsieh, K.L. (2006). Hotelling's T2 charts with variable sample size and control limit. Eur. J. Oper. Res. doi:10.1016/j.ejor.2006.09.046.
  • Chengalur, I.N., Arnold, J.C., Reynolds, Jr., M.R. (1989). Variable sampling intervals for multiparameter shewhart charts. Commun. Stat. – Theory Methods 18:1769–1792. doi:10.1080/03610928908830000.
  • Cinlar, E. (1975). Introduction to Stochastic Process. Englewood Cliffs, NJ: Prentice Hall.
  • Costa, A.F.B. (1998). VSSI X-bar charts with sampling at fixed times. Commun. Stat. – Theory Methods 27:2853–2869.
  • Costa, A.F.B. (1999). Xbar charts with variable parameters. J. Qual. Technol. 31:408–416.
  • Faraz, A., Parsian, A. (2006). Hotelling's T2 control chart with double warning lines. Stat. Pap. 47(4):569--593.
  • Faraz, A., Moghadam, M.B. (2009). Hotelling's T2 control chart with two-state adaptive sample size. Qual. Quan., Int. J. Methodol. 43:903–913. doi:10.1007/s11135-008-9167-x.
  • Faraz, A., Saniga, E. (2009). A unification and some corrections to Markov chain approaches to develop variable ratio sampling scheme control charts. Stat. Pap. doi:10.1007/s00362-009-0288-7.
  • Faraz, A., Kazemzade, R.B., Saniga, E. (2010). Economic and economical statistical design of Hotelling's T2 control chart with two-state adaptive sample size. J. Stat. Comput. Simul. 80(12):1299–1316. doi:10.1080/00949650903062574.
  • Faraz, A., Chalaki, K., Moghadam, M.B. (2011). On the properties of the Hotelling's T2 control chart with VSI scheme. Qual. Quan., Int. J. Methodol. 45(3):579–586. doi:10.1007/s11135-010-9314-z.
  • Faraz, A., Saniga, E. (2011). Economic and economical statistical design of Hotelling's T2 control chart with double warning lines. Qual. Reliab. Eng. Int. 27(2):125–139. doi:10.1002/qre.1095.
  • Faraz, A., Heuchenne, C., Saniga, E. (2012a). Optimal T2 control chart with a double sampling scheme – an alternative to the MEWMA chart. Qual. Reliab. Eng. Int. 28:751–760. doi:10.1002/qre.1268.
  • Faraz, A., Kazemzadeh, R.B., Parsian, A., Moghadam, M.B. (2012b). On the advantages of economically designed variable sample sizes and sampling intervals T2 control chart. Qual. Quan., Int. J. Methodol 46:1323–1336. doi:10.1007/s11135-010-9325-9.
  • Faraz, A., Celano, G., Heuchenne, C., Saniga, E., Fichera, S. (2013a). The variable parameters T2 chart with run rules. Stat. Pap. doi:10.1007/s00362-013-0537-7.
  • Faraz, A., Heuchenne, C., Saniga, E., Costa, A.F.B. (2013b). Double objective economic statistical design of the VP T2 control chart: Wald's identity approach. J. Stat. Comput. Simul. doi:10.1080/00949655.2013.784315.
  • Hotelling, H. (1947). Multivariate quality control – illustrated by the air testing of sample bombsights. In: Eisenhart, C., Hastay, M.W., Wallis, W.A., eds. Techniques of Statistical Analysis. New York: MacGraw-Hill.
  • Seif, A., Faraz, A., Heuchenne, C., Moghadam, M.B. (2011a). Statistical merits and economic evaluation of the Hotelling's T2 control chart with variable sample sizes and control limits. Arab. J. Sci. Eng. 36:1461–1470. doi:10.1007/s13369-011-0124-y.
  • Seif, A., Faraz, A., Heuchenne, C., Saniga, E., Moghadam, M.B. (2011b). Economic-statistical design of T2 control chart with the VSSC sampling scheme. J. Appl. Stat. 38:2459–2469. doi:10.1080/02664763.2011.559205.
  • Tornga, C.C., Lee, P.H. (2009). The performance of double sampling control charts under non normality. Commun. Stat. – Simul. Comput. 38:541–557. doi:10.1080/03610910802571188.
  • Torabian, M., Moghadam, M.B., Faraz, A. (2010). Economically designed Hotelling's T2 control chart using VSICL schemes. Arab. J. Sci. Eng. 35:251–263.
  • Lin, Y. (2009). The variable parameters X-bar control charts for monitoring autocorrelated processes. Commun. Stat. – Simul. Comput. 38:729–749. doi:10.1080/03610910802645339.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.