References
- Fissore, D.; Pisano, R.; Barresi, A. A. Process Analytical Technology for Monitoring Pharmaceuticals Freeze-Drying. A Comprehensive Review. Dry Technol. 2018, 36, 1839–1865. DOI: https://doi.org/10.1080/07373937.2018.1440590.
- Thompson, T. N. Process and Device for Determining the End of a Primary Stage of Freeze-Drying. US Patent 4,780,964, Nov 1, 1988.
- Nail, S. L.; Johnson, W. Methodology for in-Process Determination of Residual Water in Freeze-Dried Products. Dev. Biol. Stand. 1992, 74, 137–151.
- Grassini, S.; Parvis, M.; Barresi, A. A. Inert Thermocouple with Nanometric Thickness for Lyophilization Monitoring. IEEE Trans. Instrum. Meas. 2013, 62, 1276–1283. DOI: https://doi.org/10.1109/TIM.2012.2223312.
- Oddone, I.; Fulginiti, D.; Barresi, A. A.; Grassini, S.; Pisano, R. Non-Invasive Temperature Monitoring in Freeze-Drying: Control of Freezing as a Case Study. Dry Technol. 2015, 33, 1621–1630. DOI: https://doi.org/10.1080/07373937.2015.1040026.
- Barresi, A. A.; Velardi, S. A.; Pisano, R.; Rasetto, V.; Vallan, A.; Galan, M. In-Line Control of the Lyophilization Process. A Gentle PAT Approach Using Software Sensors. Int. J. Refrig. 2009, 32, 1003–1014. DOI: https://doi.org/10.1016/j.ijrefrig.2008.10.012.
- Velardi, S. A.; Hammouri, H.; Barresi, A. A. In-Line Monitoring of the Primary drying phase of the Freeze-Drying Process in Vial by Means of a Kalman Filter Based Observer. Chem. Eng. Res. Des. 2009, 87, 1409–1419. DOI: https://doi.org/10.1016/j.cherd.2009.03.011.
- Velardi, S. A.; Hammouri, H.; Barresi, A. A. Development of a High Gain Observer for in-Line Monitoring of Sublimation in Vial Freeze-Drying. Dry Technol. 2010, 28, 256–268. DOI: https://doi.org/10.1080/07373930903530204.
- Bosca, S.; Barresi, A. A.; Fissore, D. Design of a Robust Soft-Sensor to Monitor in-Line a Freeze-Drying Process. Dry Technol. 2015, 33, 1039–1050. DOI: https://doi.org/10.1080/07373937.2014.982250.
- Schneid, S.; Gieseler, H. Evaluation of a New Wireless Temperature Remote Interrogation System (TEMPRIS) to Measure Product Temperature during Freeze Drying. AAPS PharmSciTech 2008, 9, 729–739. DOI: https://doi.org/10.1208/s12249-008-9099-8.
- Corbellini, S.; Parvis, M.; Vallan, A. In-Process Temperature Mapping System for Industrial Freeze Dryers. IEEE Trans. Instrum. Meas. 2010, 59, 1134–1140. DOI: https://doi.org/10.1109/TIM.2010.2040909.
- Jennings, T. A.; Duan, H. Calorimetric Monitoring of Lyophilization. PDA J. Pharm. Sci. Technol. 1995, 49, 272–282.
- Chen, R.; Slater, N. K. H.; Gatlin, L. A.; Kramer, T.; Shalaev, E. Y. Comparative Rates of Freeze-Drying for Lactose and Sucrose Solutions as Measured by Photographic Recording, Product Temperature, and Heat Flux Transducer. Pharm. Dev. Technol. 2008, 13, 367–374. DOI: https://doi.org/10.1080/10837450802244744.
- Monteiro Marques, J. P.; Le Loch, C.; Wolff, E.; Rutledge, D. N. Monitoring Freeze‐Drying by Low Resolution Pulse NMR: Determination of Sublimation End Point. J. Food Sci. 1991, 56, 1707–1710. DOI: https://doi.org/10.1111/j.1365-2621.1991.tb08676.x.
- Remmele, R. L.; Stushnoff, C.; Carpenter, J. F. Real-Time in Situ Monitoring of Lysozyme during Lyophilization Using Infrared Spectroscopy: Dehydration Stress in the Presence of Sucrose. Pharm. Res. 1997, 14, 1548–1555. DOI: https://doi.org/10.1023/A:1012170116311.
- Brülls, M.; Folestad, S.; Sparén, A.; Rasmuson, A. In-Situ Near-Infrared Spectroscopy Monitoring of the Lyophilization Process. Pharm. Res. 2003, 20, 494–499. DOI: https://doi.org/10.1023/A:1022680810474
- De Beer, T. R. M.; Wiggenhorn, M.; Veillon, R.; Debacq, C.; Mayeresse, Y.; Moreau, B.; Burggraeve, A.; Quinten, T.; Friess, W.; Winter, G.; et al. Importance of Using Complementary Process Analyzers for the Process Monitoring, Analysis, and Understanding of freeze Drying. Anal. Chem. 2009, 81, 7639–7649. DOI: https://doi.org/10.1021/ac9010414.
- Tang, X.; Pikal, M. J. Design of Freeze-Drying Processes for Pharmaceuticals: Practical Advice. Pharm. Res. 2004, 21, 191–200. DOI: https://doi.org/10.1023/B:PHAM.0000016234.73023.75.
- Pikal, M. J.; Shah, S.; Senior, D.; Lang, J. E. Physical Chemistry of Freeze-Drying: Measurement of Sublimation Rates for Frozen Aqueous Solutions by a Microbalance Technique. J. Pharm. Sci. 1983, 72, 635–650. DOI: https://doi.org/10.1002/jps.2600720614.
- Bruttini, R.; Rovero, G.; Baldi, G. Experimentation and Modeling of Pharmaceutical Lyophilization Using a Pilot-Plant. Chem. Eng. J. Biochem. Eng. 1991, 45, B67–B77. DOI: https://doi.org/10.1016/0300-9467(91)80020-W.
- Rovero, G.; Ghio, S.; Barresi, A. A. Development of a Prototype Capacitive Balance for Freeze-Drying Studies. Chem. Eng. Sci. 2001, 56, 3575–3584. DOI: https://doi.org/10.1016/S0009-2509(01)00025-2.
- Roth, C.; Winter, G.; Lee, G. Continuous Measurement of Drying Rate of Crystalline and Amorphous Systems during Freeze-Drying Using an in Situ Microbalance Technique. J. Pharm. Sci. 2001, 90, 1345–1355. DOI: https://doi.org/10.1002/jps.1087.
- Wiggenhorn, M.; Presser, I.; Winter, G. The Current State of PAT in Freeze-Drying. Am. Pharm. Rev. 2005, 8, 38–44.
- Barresi, A. A.; Pisano, R.; Fissore, D.; Rasetto, V.; Velardi, S. A.; Vallan, A.; Parvis, M.; Galan, M. Monitoring of the Primary Drying of a Lyophilization Process in Vials. Chem. Eng. Process. 2009, 48, 408–423. DOI: https://doi.org/10.1016/j.cep.2008.05.004.
- Carullo, A.; Vallan, A. Measurement Uncertainty Issues in Freeze-Drying Processes. Measurement 2012, 45, 1706–1712. DOI: https://doi.org/10.1016/j.measurement.2012.04.017.
- Patel, S. M.; Doen, T.; Pikal, M. J. Determination of End Point of Primary Drying in Freeze-Drying Process Control. AAPS PharmSciTech 2010, 11, 73–84. DOI: https://doi.org/10.1208/s12249-009-9362-7.
- Salzberg, F. Pulsed Pirani Vacuum Gauge. In Proceedings of 4th International Conference on Lyophilization and Freeze-Drying, Dublin, Ireland, October 17–19, 2007.
- Bardat, A.; Biguet, J.; Chatenet, E.; Courteille, F. Moisture Measurement: A New Method for Monitoring Freeze-Drying Cycles. J. Parenter. Sci. Technol. 1993, 47, 293–299.
- Bouldoires, J. P. 1969 Etude expérimentale des transferts de chaleur et de masse encours de lyophilisation par mesures diélectriques et par mesure de pression de vapeur. In Proceedings of Symposium on Thermodynamic Aspects of Freeze-Drying, International Institute of Refrigeration: Cleveland.
- Genin, N.; Rene, F.; Corrieu, G. A Method for on-Line Determination of Residual Water Content and Sublimation End-Point during Freeze-Drying. Chem. Eng. Process. 1996, 35, 255–263. DOI: https://doi.org/10.1016/0255-2701(95)04131-1.
- Rambhatla, S.; Ramot, R.; Bhugra, C.; Pikal, M. J. Heat and Mass Transfer Scale-up Issues during Freeze-Drying: II. Control and Characterization of the Degree of Supercooling. AAPS PharmSciTech 2004, 5, 54–59. article no. 58, DOI: https://doi.org/10.1208/pt050458.
- Chouvenc, P.; Vessot, S.; Andrieu, J.; Vacus, P. Optimization of the Freeze-Frying Cycle: A New Model for Pressure Rise Analysis. Dry Technol. 2004, 22, 1577– 1601. DOI: https://doi.org/10.1081/DRT-200025605.
- Trelea, I. C.; Passot, S.; Fonseca, F.; Marin, M. An Interactive Tool for the Optimization of Freeze-Drying Cycles Based on Quality Criteria. Dry Technol. 2007, 25, 741–751. DOI: https://doi.org/10.1080/07373930701370100.
- Roy, M. L.; Pikal, M. J. Process Control in Freeze-Drying: Determination of the End Point of Sublimation Drying by an Electronic Moisture Sensor. J. Parenter. Sci. Technol. 1989, 43, 60–66.
- Jennings, T. A. Residual Gas Analysis and Vacuum Freeze Drying. J. Parenter. Drug Assoc. 1980, 34, 62–69.
- Willemer, H. Measurements of Temperatures, Ice Evaporation Rates and Residual Moisture Contents in Freeze-Drying. Dev. Biol. Stand. 1992, 74, 123–134.
- Connelly, J. P.; Welch, J. V. Monitor Lyophilization with Mass Spectrometer Gas Analysis. J. Parenter. Sci. Technol. 1993, 47, 70–75.
- Ganguly, A.; Stewart, J.; Rhoden, A.; Volny, M.; Saad, N. Mass Spectrometry in Freeze-Drying: Motivations for Using a Bespoke PAT for Laboratory and Production Environment. Eur. J. Pharm. Biopharm. 2018, 127, 298–308. DOI: https://doi.org/10.1016/j.ejpb.2018.02.036.
- Kessler, W. J.; Davis, S. J.; Mulhall, P. A.; Finson, M. L. System for monitoring a drying process. US Patent 0208191 A1, Sep 21, 2006.
- Gieseler, H.; Kessler, W. J.; Finson, M.; Davis, S. J.; Mulhall, P. A.; Bons, V.; Debo, D. J.; Pikal, M. J. Evaluation of Tunable Diode Laser Absorption Spectroscopy for in-process water vapor mass flux measurements during freeze drying . J. Pharm. Sci. 2007, 96, 1776–1793. DOI: https://doi.org/10.1002/jps.20827.
- Mayeresse, Y.; Veillon, R.; Sibille, P. H.; Nomine, C. Freeze-Drying Process Monitoring Using a Cold Plasma Ionization Device. PDA J. Pharm. Sci. Technol. 2007, 61, 160–174.
- Chase, D. R. Monitoring and Control of the Lyophilization Process Using a Mass Flow Controller. Pharm. Eng. 1998, 18, 11–17.
- Pisano, R.; Fissore, D.; Barresi, A. A. Noninvasive Monitoring of a Freeze-Drying Process for Tert-Butanol/Water Cosolvent-Based Formulations. Ind. Eng. Chem. Res. 2016, 55, 5670–5680. DOI: https://doi.org/10.1021/acs.iecr.5b04299.
- Milton, N.; Pikal, M. J.; Roy, M. L.; Nail, S. L. Evaluation of Manometric Temperature Measurement as a Method of Monitoring Product Temperature during Lyophilization. PDA J. Pharm. Sci. Technol. 1997, 51, 7–16.
- Oetjen, G. W.; Haseley, P.; Klutsch, H.; Leineweber, M. Method for controlling a freeze-drying process. United States Patent 6163979, 2000.
- Liapis, A. I.; Sadikoglu, H. Dynamic Pressure Rise in the Drying Chamber as a Remote Sensing Method for Monitoring the Temperature of the Product during the Primary Drying Stage of Freeze-Drying. Dry Technol. 1998, 16, 1153– 1171. DOI: https://doi.org/10.1080/07373939808917458.
- Velardi, S. A.; Rasetto, V.; Barresi, A. A. Dynamic Parameters Estimation Method: Advanced Manometric Temperature Measurement Approach for Freeze-Drying Monitoring of Pharmaceutical Solutions. Ind. Eng. Chem. Res. 2008, 47, 8445–8457. DOI: https://doi.org/10.1021/ie7017433.
- Fissore, D.; Pisano, R.; Barresi, A. A. On the Methods Based on the Pressure Rise Test for Monitoring a Freeze-Drying Process. Drying Technol. 2010, 29, 73–90. DOI: https://doi.org/10.1080/07373937.2010.482715.
- Pisano, R.; Fissore, D.; Barresi, A. A. A. A New Method Based on the Regression of Step Response Data for Monitoring a Freeze-Drying Cycle. J. Pharm. Sci. 2014, 103, 1756–1765. DOI: https://doi.org/10.1002/jps.23976.
- Velardi, S. A.; Barresi, A. A. Development of Simplified Models for the Freeze-Drying Process and Investigation of the Optimal Operating Conditions. Chem. Eng. Res. Des. 2008, 86, 9–22. DOI: https://doi.org/10.1016/j.cherd.2007.10.007.
- Pisano, R.; Fissore, D.; Velardi, S. A.; Barresi, A. A. In-Line Optimization and Control of an Industrial Freeze-Drying Process for Pharmaceuticals. J. Pharm. Sci. 2010, 99, 4691–4709. DOI: https://doi.org/10.1002/jps.22166.
- Rambhatla, S.; Pikal, M. J. Heat and Mass Transfer Scale-up Issues during Freeze-Drying, I: Atypical Radiation and the Edge Vial Effect. AAPS PharmSciTech 2003, 4, 22–120. DOI: https://doi.org/10.1208/pt040214.
- Barresi, A. A.; Pisano, R.; Rasetto, V.; Fissore, D.; Marchisio, D. L. Model-Based Monitoring and Control of Industrial Freeze-Drying Processes: Effect of Batch Nonuniformity. Dry Technol. 2010, 28, 577–590. DOI: https://doi.org/10.1080/07373931003787934.