Publication Cover
CRANIO®
The Journal of Craniomandibular & Sleep Practice
Volume 4, 1986 - Issue 2
4
Views
12
CrossRef citations to date
0
Altmetric
Original Articles

Patient with Lymphadenopathy Following Temporomandibular Joint Arthroplasty with Proplast

Pages 172-178 | Published online: 19 Feb 2016

References

  • Homsy, C A., and Anderson, M.S. Functional stabilization of prostheses with a porous low modulus materials system. In Biocompatability of Implant Materials. London: Sector Publishing Co., 1976. pp. 85–92.
  • Spector, M., Harmon. S.L., and Kreutner, A. Characteristics of tissue growth into proplast and porous polyethylene implants in bone. J Biomed Mat Res 1979: 13: 677–692.
  • Halstead, A., Jones. C.W., and Rawlings, R.D. A study of the reaction of human tissue to proplast. J Biomed Mat Res 1979: 13: 121–134.
  • Eftekhar, N.S. Principles of Total Hip Arthroplasty. St. Louis: The C.V. Mosby Co., 1978.
  • Spector, M. Bone ingrowth into porous polymers. In Biocompatability of Orthopedic Implants. Vol. II. D.F. Williams, ed. Boca Raton. Honda: CRC Press. 1982. pp. 55–88.
  • Homsy, C.A. Biocompatability of perfluorinated polymers and composites of these polymers. In Biocompatability of Clinical Implant Materials. Vol. II. D.F. Williams, ed. Boca Raton. Florida: CRC Press. 1981. pp. 59–77.
  • Kent, J.N., and Zide, M.F. Wound healing: bone and biomaterials. Otolaryng Clin N Am 1984: 17: 273–319.
  • Blank, D.M., Stein. A.C., Gold. B.D., and Berger, J. Treatment of protracted bilateral mandibular dislocation with Proplast-vitalium prostheses. Oral Surg 1982: 53: 335–339.
  • Kent, J.N., Misiek, D.J., Akin. R.K., Hinds, E.C., and Homsy, C.S. Temporomandibular joint condylar prosthesis: a ten-year report. J Oral Maxillofac Surg 1983: 41: 245–254.
  • Gallagher, D.M., and Wolford, L.M. Comparison of silastic and pro plast in the temporomandibular joint after condylectomy for osteoarthritis. J Oral Maxillofac Surg 1982: 40: 627–630.
  • Kiersch, T.A. The use of Proplast Teflon implants for meniscectomy and disc repair in the temporomandibular joint. In Clinical Congress on Reconstruction with Biomaterials: Current Assessment and Temporomandibular Joint: Surgical Update, Program Outlines and Abstracts. Jan. 20–22. 1984.
  • El Deeb. M. Department of Oral Surgery, University of Minnesota. Personal communication.
  • Timmis, D P., Aragon, S.B., Van Sickels, J.E., and Aufdemorte, T.B. A comparative study of alloplatic TMJ meniscal replacement in rabbits. Case Reports and Outlines of Scientific Sessions 67th Annual Meeting. American Association of Oral and Maxillofacial Surgeons. 1985. p. 40.
  • Charnley, J. An artificial bearing in the hip joint: implications in biological lubrication. Fed Proc 1966: 25: 1079–1081.
  • Leidholt, J.D., and Gorman, N.A. Teflon hip prostheses in dogs. J Bone Surg 1965: 47-A: 1414–1420.
  • Buchhorn, G.H., and Willert, H.G. Effects of plastic wear particles on tissue. In Biocompatability of Orthopedic Implants. Vol. I. D.F. Williams, ed. Boca Raton. Florida: CRC Press. 1982. pp. 249–267.
  • Meachim, G., and Pedley, R.B. The tissue response at implant sites. In Fundamental Aspects of Biocompatability. Vol. I. D.F. Williams, ed. Boca Raton. Florida: CRC Press, 1981. pp. 107–143.
  • Forster, I.W., Ralis. Z.A., McKibbin. B., and Jenkins, D.H.R. Biological reaction to carbon fiber implants: the formation and structure of a carbon induced neo-tendon. Clin Orthop Rel Res 1978: No. 131: 299–307.
  • Kramer, B., and King, R.E. The histologic appearance of carbon fibre implants and neo-ligament in man. S Afr Med J 1983: 63: 113–115.
  • Mendes, D.G., lusim. M., Angel. D., Rotem, A., Roffman, M., Grish-kan. A., Mordohovich, D., and Boss, J. Histologic pattern of biomechanic properties of the carbon fiber-augmented ligament tendon: a laboratory and clinical study. Clin Orthop Rel Res 1985: No. 196: 51–60.
  • Benjamin, E., Ahmed, A., Rashid, A.T.M.F., and Wright, D.H. Silicone lymphadenopathy: a report of two cases, one with concomitant malignant lymphoma. Diag Histopath 1982:5: 133–141.
  • Christie, A.J., Weinberger, K.A., and Dietrich, M. Silicone lymphadenopathy and synovitis: complications of silicone elastomer finger-joint prostheses. JAMA 1977:237: 1463–1464.
  • Dolwick, M.F., and Aufdemorte, T.B. Silicone-induced foreign body reaction and lymphadenopathy after temporomandibular joint arthroplasty. Oral Surg Oral Med Oral Path 1985: 59: 499–452.
  • Harvey, T., and Leahy, M. Silicone lymphadenopathy: a complication of silicone elastomer finger joint prostheses. J Rheumat 1984: 11: 104–105.
  • Kircher, I. Silicone lymphadenopathy: a complication of silicone elastomer finger joint prostheses. Human Path 1980: 11: 240–244.
  • Nalbandian, R.M., Swanson. A., and Maupin, B.K. Long term silicone implant arthroplasty: implications of animal and human autopsy findings. JAMA 1983:250: 1195–1198.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.