References
- W. E. Gifford and R. C. Longsworth, “Pulse tube refrigeration,” J. Eng. Ind., vol. 86, no. 3, pp. 264–268, 1964. DOI: https://doi.org/10.1115/1.3670530.
- E. I. Mikulin, A. A. Tarasov, and M. P. Shkrebyonock, “Low-temperature expansion pulse tubes,” Adv. Cryo. Eng., vol. 29, pp. 629–637, 1984.
- S. Zhu, P. Wu, and Z. Chen, “Double inlet pulse tube refrigerators: an important improvement,” Cryogenics, vol. 30, no. 6, pp. 514–520, 1990. DOI: https://doi.org/10.1016/0011-2275(90)90051-D.
- H. Yoshikazu, S. Masao, and M. Masahide, “Simulation of thermodynamics aspects about pulse tube refrigerator,” AIP Conf. Proc., vol. 710, pp. 1500–1507, 2004.
- J. S. Cha, S. M. Ghiaasiaan, P. V. Desai, J. P. Harvey, and C. S. Kirkconnell, “Multi-dimensional flow effects in pulse tube refrigerators,” Cryogenics, vol. 46, no. 9, pp. 658–665, 2006. DOI: https://doi.org/10.1016/j.cryogenics.2006.03.001.
- X. B. Zhang, L. M. Qiu, Z. H. Gan, and Y. L. He, “CFD study of a simple orifice pulse tube cooler,” Cryogenics, vol. 47, no. 5–6, pp. 315–321, 2007. DOI: https://doi.org/10.1016/j.cryogenics.2007.03.005.
- Y. P. Banjare, R. K. Sahoo, and S. K. Sarangi, “CFD simulation of a Gifford–McMahon type pulse tube refrigerator,” Int. J. Therm. Sci., vol. 48, no. 12, pp. 2280–2287, 2009. DOI: https://doi.org/10.1016/j.ijthermalsci.2009.04.013.
- J. Y. Hu, X. Z. Zhang, Y. Y. Chen, L. M. Zhang, and E. C. Luo, “Experimental study of the connecting tube at the cold end of a U-shaped pulse tube cryocooler,” Cryogenics, vol. 72, pp. 77–81, 2015. DOI:https://doi.org/10.1016/j.cryogenics.2015.09.004.
- D. S. Antao and B. Farouk, “Computational fluid dynamics simulations of an orifice type pulse tube refrigerator: effects of operating frequency,” Cryogenics, vol. 51, no. 4, pp. 192–201, 2011. DOI: https://doi.org/10.1016/j.cryogenics.2011.02.001.
- D. S. Antao and B. Farouk, “Numerical simulations of transport processes in a pulse tube cryocooler: effects of taper angle,” Int. J. Heat Mass Transf., vol. 54, no. 21–22, pp. 4611–4620, 2011. DOI: https://doi.org/10.1016/j.ijheatmasstransfer.2011.06.016.
- S. Moldenhauer, T. Stark, C. Holtmann, and A. Thess, “The pulse tube engine: a numerical and experimental approach on its design, performance, and operating conditions,” Energy, vol. 55, pp. 703–715, 2013. DOI:https://doi.org/10.1016/j.energy.2013.03.052.
- S. Moldenhauer, A. Thess, C. Holtmann, and C. Fernandez-Aballi, “Thermodynamic analysis of a pulse tube engine,” Energ. Convers. Manage., vol. 65, pp. 810–818, 2013. DOI:https://doi.org/10.1016/j.enconman.2012.03.013.
- L. Chen, Y. Zhang, E. Luo, T. Li, and X. Wei, “CFD analysis of thermodynamic cycles in a pulse tube refrigerator,” Cryogenics, vol. 50, no. 11–12, pp. 743–749, 2010. DOI: https://doi.org/10.1016/j.cryogenics.2010.08.004.
- F. Barrette and R. Arsalan, “Modeling pulse tube cryocoolers with CFD,” Adv. Cryog. Eng., vol. 49, pp. 1493–1499, 2004.
- S. Celik and O. Ekren, “Two-phase refrigerant flow in the evaporator of a stirling cooling system with a thermosyphon loop,” Experimental Heat Transfer, vol. 33, no. 4, pp. 305–317, 2020. DOI: https://doi.org/10.1080/08916152.2019.1635227.
- J. Y. Hu, et al., “A high-efficiency coaxial pulse tube cryocooler with 500W cooling capacity at 80K,” Cryogenics, vol. 62, pp. 7–10, 2014. DOI:https://doi.org/10.1016/j.cryogenics.2014.03.010.
- D. S. Antao and B. Farouk, “Numerical and experimental characterization of the inertance effect on pulse tube refrigerator performance,” Int. J. Heat Mass Transf., vol. 76, pp. 33–44, 2014. DOI:https://doi.org/10.1016/j.ijheatmasstransfer.2014.04.006.
- J. Ko, et al., “Suppression of performance degradation due to cold-head orientation in GM-type pulse tube refrigerator,” Progress in Superconductivity and Cryogenics, vol. 14, no. 4, pp. 50–53, 2012. DOI: https://doi.org/10.9714/sac.2012.14.4.050.
- S. Kasthurirengan, et al. “Studies on a single stage GM type pulse tube cryocooler using an indigenous helium compressor.” Proceedings of the Twentieth International Cryogenic Engineering Conference (ICEC20), Beijing, China, vol. 20, pp. 253–256, 2005.
- S. Kasthurirengan, et al., “Experimental and theoretical studies of a two-stage pulse tube cryocooler operating down to 3 K,” Int. J. Heat Mass Transf., vol. 52, no. 3–4, pp. 986–995, 2009. DOI: https://doi.org/10.1016/j.ijheatmasstransfer.2008.07.028.
- Z. H. Gan, H. Z. Liu, Z. Z. Cheng, L. M. Qiu, and G. B. Chen, “Experiment on a Single-stage GM Type Pulse Tube Cryocooler near 20 K,” Proceedings of the Twentieth International Cryogenic Engineering Conference (ICEC20), Beijing, China, vol. 20, pp. 221–224, 2005.
- Z. H. Gan and G. Thummes, “Temperature hysteresis in a GM-type orifice pulse tube refrigerator.” Proceedings of the Twentieth International Cryogenic Engineering Conference (ICEC20), Beijing, China, vol. 20, pp. 297–300, 2005.
- L. M. Qiu, Y. L. He, Z. H. Gan, and G. B. Chen, “A single-stage pulse tube cooler reached 12.6K,” Cryogenics, vol. 45, no. 9, pp. 641–643, 2005. DOI: https://doi.org/10.1016/j.cryogenics.2005.08.001.
- Y. Tian, et al., “Experimental study on W-shaped regenerative radiant tube with novel structure burner for performance optimization,” Experimental Heat Transfer, vol. 30, no. 6, pp. 131–147, 1990. DOI: https://doi.org/10.1016/0011-2275(90)90051-D.
- A. K. Solanki and R. Kumar, “Condensation heat transfer and pressure drop characteristics of R-134a inside the flattened tubes at high mass flux and different saturation temperature,” Experimental Heat Transfer, vol. 32, no. 1, pp. 69–84, 2019. DOI: https://doi.org/10.1080/08916152.2018.1485781.
- S. Thota, G. C. Srikantaiah, B. S. Akkimaradi, A. A. Ambirajan, and N. Gsvl, “Numerical and experimental studies of parasitic heat losses in coldfinger of a pulse tube cryocooler in off-state condition,” Heat Transfer Engineering, vol. 40, no. 11, pp. 959–970, 2019. DOI: https://doi.org/10.1080/01457632.2018.1446892.
- P. B. Gujarati, K. P. Desai, H. B. Naik, and M. D. Atrey, “Transient analysis of single stage GM type double inlet pulse tube cryocooler,” IOP Conference Series: Materials Science and Engineering, Tucson, AZ, vol. 101, p. 012033, 2015.
- A. Biswas and S. K. Ghosh, “Experimental and numerical investigation on performance of a double inlet type cryogenic pulse tube refrigerator,” Heat and Mass Transfer, vol. 52, no. 9, pp. 1899–1908, 2016. DOI: https://doi.org/10.1007/s00231-015-1717-x.
- Y. Jiang, G. Chen, and T. Guenter, “Experimental investigation on DC flow suppression and refrigeration characteristics of a high-performance single-stage GM-type PTC,” Proceedings of the Twentieth International Cryogenic Engineering Conference (ICEC20), Beijing, China, pp. 209–212, 2005.
- B. Y. Du, “Analysis of DC control in double-inlet GM type pulse tube refrigerators for detectors,” Infrared Technology and Applications, and Robot Sensing and Advanced Control, vol. 10157, pp. 101570B, 2016.
- G. Q. Lu and P. Cheng, “On cycle-averaged pressure in a G-M type pulse tube refrigerator,” Cryogenics, vol. 42, no. 5, pp. 287–293, 2002. DOI: https://doi.org/10.1016/S0011-2275(02)00040-1.
- S. Fujimoto, Y. M. Kang, and Y. Matsubara, “Development of a 5 to 20 W at 80 K GM pulse tube cryocooler,” Cryocoolers Conf., vol. 10, pp. 213–220, 2002.
- A. Ravex, P. Rolland, and J. Liang, “Experimental study and modelisation of a pulse tube refrigerator,” Cryogenics, vol. 32, pp. 9–12, 1992. DOI:https://doi.org/10.1016/0011-2275(92)90097-T.
- C. K. Mangrulkar, et al., “Thermal performance escalation of cross flow heat exchanger using in-line elliptical tubes,” Exp. Heat Transfer, vol. 33, no. 7, pp. 587–612, 2020. DOI: https://doi.org/10.1080/08916152.2019.1704946.
- Fluent 6.1 user manual. Fluent Inc, 2003.
- Fluent 6.1 user defined function manual. Fluent Inc., 2003.