Publication Cover
Baylor University Medical Center Proceedings
The peer-reviewed journal of Baylor Scott & White Health
Volume 26, 2013 - Issue 4
86
Views
1
CrossRef citations to date
0
Altmetric
Single-Patient Studies

Critical Lower Limb Ischemia from an Embolized Angio-Seal Closure Device

Pages 398-400 | Published online: 11 Dec 2017

  • Turi ZG. Overview of vascular closure devices. Endovasc Today April 2004: 19–20.
  • Dauerman HL, Rao SV, Resnic FS, Applegate RJ. Bleeding avoidance strategies. Consensus and controversy. J Am Coll Cardiol 2011;58 (1): 1–10.
  • Marso SP, Amin AP, House JA, Kennedy KF, Spertus JA, Rao SV, Cohen DJ, Messenger JC, Rumsfeld JS; National Cardiovascular Data Registry. Association between use of bleeding avoidance strategies and risk of periprocedural bleeding among patients undergoing percutaneous coronary intervention. JAMA 2010;303 (21): 2156–2164.
  • Applegate RJ, Sacrinty MT, Kutcher MA, Kahl FR, Gandhi SK, Santos RM, Little WC. Trends in vascular complications after diagnostic cardiac catheterization and percutaneous coronary intervention via the femoral artery, 1998 to 2007. JACC Cardiovasc Interv 2008;1 (3): 317–326.
  • Ahmed B, Piper WD, Malenka D, VerLee P, Robb J, Ryan T, Herne M, Phillips W, Dauerman HL. Significantly improved vascular complications among women undergoing percutaneous coronary intervention: a report from the Northern New England Percutaneous Coronary Intervention Registry. Circ Cardiovasc Interv 2009;2 (5): 423–429.
  • Nikolsky E, Mehran R, Halkin A, Aymong ED, Mintz GS, Lasic Z, Negoita M, Fahy M, Krieger S, Moussa I, Moses JW, Stone GW, Leon MB, Pocock SJ, Dangas G. Vascular complications associated with arteriotomy closure devices in patients undergoing percutaneous coronary procedures: a meta-analysis. J Am Coll Cardiol 2004;44 (6): 1200–1209.
  • Tavris DR, Dey S, Albrecht-Gallauresi B, Brindis RG, Shaw R, Weintraub W, Mitchel K. Risk of local adverse events following cardiac catheterization by hemostasis device use—phase II. J Invasive Cardiol 2005;17 (12): 644–650.
  • Sanborn TA, Ebrahimi R, Manoukian SV, McLaurin BT, Cox DA, Feit F, Hamon M, Mehran R, Stone GW. Impact of femoral vascular closure devices and antithrombotic therapy on access site bleeding in acute coronary syndromes: The Acute Catheterization and Urgent Intervention Triage Strategy (ACUITY) trial. Circ Cardiovasc Interv 2010;3 (1): 57–62.
  • Tavris DR, Gallauresi BA, Lin B, Rich SE, Shaw RE, Weintraub WS, Brindis RG, Hewitt K. Risk of local adverse events following cardiac catheterization by hemostasis device use and gender. J Invasive Cardiol 2004;16 (9): 459–464.
  • Kalapatapu VR, Ali AT, Masroor F, Moursi MM, Eidt JF. Techniques for managing complications of arterial closure devices. Vasc Endovascular Surg 2006;40 (5): 399–408.
  • Rilling WS, Dicker M. Arterial puncture closure using a collagen plug, I. (Angio-Seal). Tech Vasc Interv Radiol 2003;6 (2): 76–81.
  • Thalhammer C, Aschwanden M, Jeanneret C, Labs KH, Jäger KA. Symptomatic vascular complications after vascular closure device use following diagnostic and interventional catheterisation. Vasa 2004;33 (2): 78–81.
  • Castelli P, Caronno R, Piffaretti G, Tozzi M, Lomazzi C. Incidence of vascular injuries after use of the Angio-Seal closure device following endovascular procedures in a single center. World J Surg 2006;30 (3): 280–284.
  • Abando A, Hood D, Weaver F, Katz S. The use of the Angioseal device for femoral artery closure. J Vasc Surg 2004;40 (2): 287–290.
  • Kirchhof C, Schickel S, Schmidt-Lucke C, Schmidt-Lucke JA. Local vascular complications after use of the hemostatic puncture closure device Angio-Seal. Vasa 2002;31 (2): 101–106.
  • Eidt JF, Habibipour S, Saucedo JF, McKee J, Southern F, Barone GW, Talley JD, Moursi M. Surgical complications from hemostatic puncture closure devices. Am J Surg 1999;178 (6): 511–516.
  • Balzer JO, Scheinert D, Diebold T, Haufe M, Vogl TJ, Biamino G. Postinterventional transcutaneous suture of femoral artery access sites in patients with peripheral arterial occlusive disease: a study of 930 patients. Catheter Cardiovasc Interv 2001;53 (2): 174–181.
  • Wille J, Vos JA, Overtoom TT, Suttorp MJ, van de Pavoordt ED, de Vries JP. Acute leg ischemia: the dark side of a percutaneous femoral artery closure device. Ann Vasc Surg 2006;20 (2): 278–281.
  • Steinkamp HJ, Werk M, Beck A, Teichgräber U, Haufe M, Felix R. Excimer laser-assisted recanalisation of femoral arterial stenosis or occlusion caused by the use of Angio-Seal. Eur Radiol 2001;11 (8): 1364–1370.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.