160
Views
4
CrossRef citations to date
0
Altmetric
Articles

Waveguide-based applicators for superficial hyperthermia treatment: is tuning really required?

, , &
Pages 682-690 | Received 17 Oct 2012, Accepted 26 Nov 2012, Published online: 31 Jan 2013

References

  • Vernon, CC, Hand, JW, Field, SB, Machin, D, Whaley, JB, Zee, J, Putten, WL, Rhoon, GC, and Dijk, JD, 1996. González González D, Liu FF, Goodman P, Sherar M. Radiotherapy with or without hyperthermia in the treatment of superficial localized breast cancer: results from five randomized controlled trials. International collaborative hyperthermia group, Int. J. Radiat. Oncol. Biol. Phys. 35 (1996), pp. 731–744.
  • Jones, EL, Oleson, JR, Prosnitz, LR, Samulski, TV, Vujaskovic, Z, Yu, D, Sanders, LL, and Dewhirst, MW, 2005. Randomized trial of hyperthermia and radiation for superficial tumors, J. Clin. Oncol. 23 (2005), pp. 3079–3085.
  • Overgaard, J, González González, D, Hulshof, MCCH, Arcangeli, G, Dahl, O, Mella, O, Bentzen, SM, and Hyperthermia as an adjuvant to radiation therapy of recurrent or metastatic malignant melanoma. A multicentre randomized trial by the European society for hyperthermic 25 oncology., , 1996. Int, J. Hyperthermia. 2009 (25) (1996), pp. 323–334.
  • Stauffer, PR, 2005. Evolving technology for thermal therapy of cancer, Int. J. Hyperthermia. 21 (2005), pp. 731–744.
  • Zee, J, Bruijne, M, Mens, JWM, Ameziane, A, Broekmeyer-Reurink, MP, Drizdal, T, Linthorst, M, and Rhoon, GC, 2010. Reirradiation combined with hyperthermia in breast cancer recurrences: overview of experience in Erasmus MC, Int. J. Hyperthermia. 26 (2010), pp. 638–648.
  • Bruijne, M, Zee, J, Ameziane, A, and Rhoon, GC, 2011. Quality control of superficial hyperthermia by treatment evaluation, Int. J. Hyperthermia. 27 (2011), pp. 199–213.
  • Rhoon, GC, Rietveld, PJ, and Zee, J, 1998. A 433 MHz lucite cone waveguide applicator for superficial hyperthermia, Int. J. Hyperthermia. 14 (1998), pp. 13–27.
  • Staufier, PR, Maccarini, P, Arunachalam, K, Craciunescu, O, Diederich, C, Juang, T, Rossetto, F, Schlorff, J, Milligan, A, Hsu, J, Sneed, P, and Vujaskovic, Z, 2010. Conformal microwave array (CMA) applicators for hyperthermia of diffuse chest wall recurrence, Int. J. Hyperthermia. 26 (2010), pp. 686–698.
  • Johnson, JE, Neuman, DG, Maccarini, PF, Juang, T, Stauffer, PR, and Turner, P, 2006. Evaluation of a dual-arm Archimedean spiral 5 array for microwave hyperthermia, Int. J. Hyperthermia. 22 (2006), pp. 475–490.
  • Gaag, ML, Bruijne, M, Samaras, T, Zee, J, and Rhoon, GC, 2006. Development of a guideline for the water bolus temperature in superficial hyperthermia, Int. J. Hyperthermia. 22 (2006), pp. 637–656.
  • Ito K, Furuya K, Okano Y, Hamada L. Development and characteristics of a biological tissue-equivalent phantom for microwaves. Electron. Comm. Jpn. (Part I: Commun.). 2001;84:67–77..
  • Drizdal, T, Togni, P, Visek, L, and Vrba, J, 2010. Comparison of constant and temperature dependent blood perfusion in temperature prediction for superficial hyperthermia, Radioengineering. 19 (2010), pp. 281–289.
  • Wiersma J. Hyperthermia treatment planning: for the AMC-4 system using the WF-CGFFT method [Ph.D. Thesis]. Amsterdam, The Netherlands: Academic Medical Center, University of Amsterdam; 2005..
  • Kok, HP, Greef, M, Wieringen, N, and Correia, D, 2010. Hulshof M.CCM, Zum Vörde Sive Vörding PJ, Sijbrands J, Bel A, Crezee J. Comparison of two different 70 MHz applicators for large extremity lesions: simulation and application, Int. J. Hyperthermia. 26 (2010), pp. 376–388.
  • Salahi, S, Maccarini, PF, Rodrigues, DB, Etienne, W, Landon, CD, Inman, BA, Dewhirst, MW, and Stauffer, PR, 2012. Miniature microwave applicator for murine bladder hyperthermia studies, Int. J. Hyperthermia. 28 (2012), pp. 456–465.
  • Drizdal T, Vrba J. Modification of lucite horn applicator with respect to frequency bandwidth. In: 24th Annual Meeting of the European Society for Hyperthermic Oncology; 2007; Prague, Czech Republic. p. 73..
  • Trujillo-Romero, CJ, Leija, L, and Vera, A, 2011. FEM modeling for performance evaluation of an electromagnetic oncology deep hyperthermia applicator when using monopole, inverted T, and plate antennas, Prog. Electromagn. Res. 120 (2011), pp. 99–125.
  • Gabriel, S, Lau, RW, and Gabriel, C, 1996. The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues, Phys. Med. Biol. 41 (1996), pp. 2271–2293.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.